Description
1. Commercial Introduction
Complete or renew the wiring of your electrocardiograph with the FIAB ECG patient cable Ref. F5746RC, a replacement accessory of proven quality manufactured by FIAB SpA (Vicchio, Florence, Italy), one of Europe’s leading specialists in cables and connectivity for electrocardiography. Specifically designed for equipment on the Marquette and Hellige platforms, this cable provides stable and reliable signal transmission in daily clinical practice in cardiology clinics, emergency departments, primary care and functional diagnostic centres. Its inspectable manifold is a differential advantage: it allows visual checking of the internal connections, facilitating preventive maintenance and extending the service life of the accessory. As this is a product sold on quotation, our technical-commercial team will confirm the exact compatibility with your equipment and the supply conditions.
2. Technical Explanation
The ECG patient cable is the element in the recording chain that transmits the cardiac electrical signal captured by the electrodes placed on the patient’s chest and limbs to the input of the electrocardiograph or monitor. The quality of the trace depends directly on the condition of the cable: deteriorated insulation, a loose connector or a fatigued flex point are sources of artefacts, interference and signal loss that can compromise the diagnosis.
This model incorporates an inspectable manifold: the housing that groups the leads can be opened to visually review the condition of the internal connections, conductors and insulation, allowing signs of wear or false contacts to be detected before they affect the quality of the recording. The patient end is fitted with snap-type terminals (press stud, referred to as CLIP by the manufacturer), the most common press-fit attachment system in electrocardiography, which couples quickly and securely to standard disposable ECG electrodes. The opposite connector, specific to the device, couples to the patient port of Marquette and Hellige devices, ensuring a firm fit and clean traces with minimal interference.
3. Technical Specifications
Specifications verified in the manufacturer’s official catalogue (fiab.it, section ECG > Patient Cables > Inspectable Manifold > Snap):
| Characteristic | Value |
|---|---|
| Reference FIAB | F5746RC |
| Packaging | 1 unit |
| Units per box (web) | 1 |
Additional catalogue data:
| Parameter | Specification |
|---|---|
| Brand | FIAB |
| Original manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Patient cable for electrocardiography (ECG) |
| Manifold / central connector | Inspectable (openable manifold) |
| Patient connection | Snap / pressure clip (CLIP) |
| Compatibility | Marquette and Hellige equipment |
| Application | Resting electrocardiography and monitoring |
| Catalogue category FIAB | ECG > Patient Cables > Inspectable Manifold > Snap |
| Presentation | 1 unit |
| Sales unit | On request (sold in complete boxes, per tariff) |
Available references:
| Reference | Description |
|---|---|
| FIAB-F5746RC | SKU Cahnos / order reference for this product |
| F5746RC | Manufacturer reference FIAB for the same cable |
Technical data according to the official manufacturer catalogue FIAB. Measurements, models and references are copied literally; unconfirmed specifications are not included.
4. Equivalences and Cross-References
Reference F5746RC is the original factory code FIAB for this ECG patient cable with inspectable manifold and snap connection compatible with Marquette and Hellige devices, also registered under the distribution SKU Cahnos FIAB-F5746RC: both designations identify the same product unit.
No reliable source has been found providing an official equivalence table authorising 1:1 replacement with cables from other manufacturers: ECG patient cables are accessories specific to the equipment-side connector, the number of leads and the electrode attachment system, so any alternative must always be validated against the electrocardiograph’s technical data sheet.
| Reference FIAB | Electrode connection | Compatibility | Level |
|---|---|---|---|
| F5746RC | Snap (clip) | Marquette, Hellige | Product reference |
| F5725RC | Snap (clip) | Schiller, Esaote, Kontron, Edan | Same family; not interchangeable 1:1 |
| F5747RC / F5747C | Snap (clip) | Fukuda Denshi | Another platform; not interchangeable |
| F5748RC / F5749RC | Snap (clip) | Burdick/Quinton and Siemens | Another platform; not interchangeable |
| F5737RC | Snap (clip) | Cardioline | Another platform; not interchangeable |
| F5738RC | Snap (clip) | Kenz | Another platform; not interchangeable |
Consult the technical department of Cahnos before considering alternatives in tenders.
5. Selection tips and variants of interest
Before placing the order, confirm that your electrocardiograph or monitor belongs to the Marquette or Hellige platforms and check the terminal type of your electrodes: this reference features a snap connection (press stud / CLIP), suitable for the standard press-fit disposable ECG electrodes on the market. If your electrode stock uses 4 mm plugs or pinch-type forceps, consider the FIAB variants from the same inspectable manifold family with a different termination, subject to technical validation.
Take advantage of the inspectable manifold by carrying out periodic checks of the internal connections, snap terminals and cable insulation, especially before diagnostic tests or prolonged recordings. It is recommended to keep a spare cable per electrocardiograph to avoid interrupting clinical activity during maintenance, and to replace the assembly at any sign of deterioration or loss of signal quality. For hospital supplies, equipment fleets or tenders, contact the technical-commercial department of Cahnos to confirm exact compatibility with your equipment base and request a tailored quote.