Description
1. Commercial Introduction
The FIAB F9053RM electrode is a high-quality disposable consumable for electrocardiographic monitoring of adult patients, manufactured by FIAB SpA (Vicchio, Florence, Italy). Its pre-wired format simplifies the care routine: each electrode already incorporates its cable, so staff only need to fix the patch on the patient’s chest and connect the 4 mm socket to the monitor lead, reducing failure points and preparation time.
Its radiotransparent foam backing and low-impedance sensor ensure a stable signal and a clean trace, even when the patient must undergo X-rays or other imaging examinations without interrupting cardiac monitoring. It is supplied in boxes of 150 units (5 bags of 30), designed for continuous use in hospital services, and is sold on quotation through Cahnos.
2. Technical Explanation
The electrode acts as an electrical interface between the patient’s skin and the monitor or electrocardiograph: it captures the heart’s electrical activity and transmits it with the least possible distortion. The radiotransparent foam backing protects the sensor and adapts to the chest contour, while the SSC sensor element (based on silver/silver chloride, Ag/AgCl) on the conductive gel offers low contact impedance and a stable signal, reducing motion artefacts.
The integrated 35 cm cable ends in a 4 mm female socket-type connection, compatible with the 4 mm lead cables of most bedside monitors, monitor defibrillators and electrocardiographs with European standard. Its radiotransparent (radiolucent) nature is its great differentiating value: the electrode remains in place during chest X-rays, catheter checks, fluoroscopy and other imaging tests without generating artefacts or interruptions in monitoring, a critical factor in ICU, emergency and interventional radiology units. It is a single-use product.
3. Technical Specifications
3.1. Manufacturer data
| Characteristic | Value |
|---|---|
| Reference FIAB | F9053RM |
| Electrode size | Ø 32 mm |
| Packaging | 150 units (5 bags of 30 units) |
| Units per box (web) | 150 |
3.2. Technical specifications of the product
| Parameter | Specification |
|---|---|
| Brand / manufacturer | FIAB (FIAB SpA, Vicchio, Florence, Italy) |
| Reference | F9053RM |
| Type | Disposable pre-wired ECG electrode for adults |
| Diameter | Ø 32 mm |
| Support | Radiotransparent foam |
| Sensor | SSC (Ag/AgCl) |
| Cable | 35 cm, pre-wired and integrated |
| Connection | 4 mm female connector (socket) |
| Radiotransparency | Yes, suitable for X-ray and imaging examinations |
| Application | ECG monitoring in adult patients |
| Use | Single-use (disposable) |
| Presentation | 150 units (5 bags of 30 units) |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references the FIAB F9053RM reference with third-party codes; any comparison between brands must be understood as comparable by category (not interchangeable 1:1). Before replacing an electrode, the diameter, backing material, sensor and gel type, connector (4 mm versus 1.5 mm DIN or snap fastener) and the monitor lead cable must be verified.
Within the FIAB family itself, variants related to the 4 mm connection and the radiotransparent neonatal foam series are documented (e.g. F9053NRM, oval format 23×30 mm), which share the backing and connector but are indicated for the neonatal population and differ in geometry and cable length: they are not interchangeable 1:1 with this adult electrode of Ø 32 mm. For any replacement, consult the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
Check the connection type of your patient cable: this reference uses a 4 mm female connector (socket). If your monitor uses a 1.5 mm DIN socket, you should select the pre-wired variant with 1.55 mm connection from the range; both formats are not interchangeable without an adapter.
Radiotransparency is advisable when the patient may require X-ray, catheter checks or other imaging tests during monitoring: it avoids removing the electrodes and keeps the trace free of artefacts. For low-weight neonatal or paediatric patients, consider the smaller radiotransparent pre-wired electrodes from the same range. Keep the bags closed in a dry place, rotate stock on a FIFO basis and respect the expiry date so as not to compromise the conductivity of the gel. For supplies, tenders or bids, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet.