We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

How to choose an intravenous cannula

20 products in the catalogue

The peripheral intravenous cannula is a device that is inserted over a needle into a peripheral vein to leave venous access in place for a limited period. It is used in healthcare settings for administering fluids and other procedures that rely on peripheral access.

The available models are safety cannulas, without wings, with wings and with an injection port. The criteria that weigh most in the purchase are the gauge in G and the size in millimetres, the length, the cannula material, the connector and the presence of needlestick protection.

  • Introcan Safety Braun G16 (1.7 × 50 mm) PUR Intravenous Safety Catheter without Wings | Ref. 4251695-01 | Box of 50 units
  • Intravenous Safety Catheter with Wings Introcan W Safety Braun G14 2.2 × 50 mm (PUR, Orange) | Ref. 4253639-01 | Box of 50 units
  • Intravenous Safety Catheter Vasofix Safety PUR Braun G16 (1.7 × 50 mm) with Injection Port | Ref. 4269179S-01 | Box of 50 units

Other related families

Products in this guide

Gauge (G)
  • 14 g 2
  • 16 g 4
  • 18 g 5
  • 20 g 2
  • 21 g 1
  • 22 g 2
  • 24 g 4
Needle size
  • 14 1
  • 0.7 × 19 3
  • 0.9 × 25 2
  • 1.1 × 25 1
  • 1.1 × 32 1
  • 1.3 × 32 2
  • 1.3 × 33 1
  • 1.3 × 45 2
Longitud
  • 1.4 cm 1
  • 1.9 cm 1
  • 2.5 cm 1
  • 3.2 cm 1
  • 4.5 cm 2
  • 5 cm 2
Diameter (mm)
  • 0.7 mm 2
  • 1.7 mm 1
  • 13 mm 4

View the Braun Safety Catheter family

Buying and selection tips

  1. Fix the gauge and the size in millimetres first

    The standard defines the size of the cannula by its outer diameter in millimetres, and the gauge in G is an optional detail. Before comparing, note the G and the mm size of the cannula you are replacing, because the same G may be offered in different lengths.

  2. Do not translate colour into gauge without knowing which product you have

    The colour codes of hypodermic needles and of peripheral IV cannulas do not match: a green cannula is 18 G, whereas the green of 21 G corresponds to a hypodermic needle. Always validate the G and the millimetres in the product description, not the colour of the hub.

  3. Decide whether you need wings and an injection port

    Within the same range there are versions with and without wings, and versions with an injection port. Wings and port change the fixation and the connection possibilities. Define both features before requesting a quote.

  4. Require a safety device in accordance with ISO 23908

    Cannulas with a safety device add needlestick protection, with ISO 23908 as the reference. Check whether the safety is passive or active. Do not assume that a cannula with wings incorporates protection: they are independent features.

  5. Check the cannula material

    The cannula material is a detail to compare; the available models indicate polyurethane (PUR) on some references. If you are comparing two references, do so with the same material.

  6. Check the connector before closing the order

    The connector may be Luer slip or Luer lock in accordance with ISO 80369-7, and it determines which infusion sets and syringes it connects to. Check the connector on the chosen reference and on the accessories you will use with it.

Compatibility

Infusion sets and syringes with a Luer tip (ISO 80369-7)
The Luer slip or Luer lock connector of the cannula must match that of the set or syringe to be attached; a different tip is not suitable for the same use.

Frequently asked questions

How do I know which gauge corresponds to the colour of the cannula I need?

The colour of peripheral IV cannulas follows its own table, different from that of hypodermic needles: a green cannula is 18 G, not 21 G. Validate the G and the millimetres in the product description.

Which connector should I check before choosing a cannula?

The Luer slip or Luer lock connector of the cannula must match that of the infusion set or syringe to be attached. Check it on each reference.

Are two cannulas of the same gauge from different brands equivalent?

They are comparable by category, but they may differ in the injection port, the wings and the cannula material. Compare those fields one by one before replacing one reference with another.

Does every cannula with wings have a safety device?

No. Wings, injection port and safety device are independent features. Check the full description of each reference.

Common questions

Translating colour into gauge using the needle table

On cannulas, green corresponds to 18 G; the green of 21 G is a hypodermic needle. Mixing the two tables leads to ordering the wrong gauge.

Choosing on G alone and forgetting the size in millimetres

The standard defines the size in millimetres and the G is optional; two references of the same G may have different lengths and not be suitable for the same purpose.

Assuming that every cannula with wings has an injection port

Wings and injection port are independent features: there are versions with wings without a port and versions with a port. Check the full description of the reference.

More products in this guide