Description
1. Introduction
The Catheter SEG G14 2.2 × 50 mm-PUR Introcan Safety Braun (Ref. 4251417-01) is a peripheral intravenous safety catheter designed to ensure reliable, stable and specially protected vascular access for both the patient and the healthcare professional. It combines the passive safety technology of the Introcan Safety system with a polyurethane (PUR) cannula, the reference material in hospitalisation for its balance between intravascular flexibility, reduced vein wall irritation and stability in prolonged access.
Its G14 gauge (2.2 mm) and 50 mm cannula length make it the largest diameter option in the family, reserved for therapies requiring very high flow rates: transfusions of blood products, rapid volume expansion, resuscitation, surgery and administration of high-viscosity drugs in adult patients, as well as for deep veins or thick subcutaneous tissue. It is supplied sterile, single-use, in the usual presentation of a box of 50 units.
2. Technical explanation of the system and procedure
The Introcan Safety system integrates a polyurethane (PUR) cannula mounted on a bevelled guide needle (over-the-needle type). During cannulation, the needle pierces the skin and the vein wall; upon confirmation of blood return through the flashback chamber, the cannula is advanced to its intravascular position and the guide needle is withdrawn: the passive safety mechanism automatically encapsulates the bevel inside a protective chamber and irreversibly locks it, without requiring any additional action from the professional.
This eliminates re-exposure to the contaminated needle and minimises the risk of biological accident due to needlestick, in line with the European directive on prevention of sharps injuries (Directive 2010/32/EU). The polyurethane softens at body temperature, favours the permanence of the access and reduces the incidence of mechanical phlebitis, maintaining a stable lumen for fluid passage. The female Luer-Lock connection is compatible with infusion lines, three-way stopcocks and standard extension sets on the market.
3. Technical Specifications
| Parameter | Value |
| Manufacturer reference | 4251417-01 (Introcan Safety PUR 14G, 2.2 × 50 mm) |
| Family / Brand | Introcan Safety · Braun (without wings) |
| Product type | Peripheral intravenous safety catheter (over-the-needle) |
| Gauge | 14G (outer diameter 2.2 mm) |
| Size (Ø × length) | 2.2 × 50 mm |
| Cannula material | Polyurethane (PUR) |
| Colour code | Orange (ISO 10555-5) |
| Safety system | Passive, with shielding and irreversible needle lock |
| Connection | Female Luer-Lock |
| Design | Wingless, without injection port |
| Use | Intravenous injection, infusion and transfusion |
| Sterilisation / use | Sterile (ethylene oxide), single-use |
| Presentation | Box of 50 units |
Gauge range of the Introcan Safety family for ordering reference:
| Reference | Gauge | Size (Ø × length) |
| 4251607-01 | 24G | 0.7 × 14 mm |
| 4251601-01 | 24G | 0.7 × 19 mm |
| 4251628-01 | 22G | 0.9 × 25 mm |
| 4251644-01 | 20G | 1.1 × 32 mm |
| 4251687-01 | 18G | 1.3 × 32 mm |
| 4251695-01 | 16G | 1.7 × 50 mm |
| 4253639-01 | 14G | 2.2 × 50 mm (with wings) |
4. Equivalences and Cross-References
Reference 4251417-01 corresponds to the Braun Introcan Safety family in the wingless configuration, G14 gauge and 50 mm length; it is recommended to confirm the code with the manufacturer before use in tenders, since the official nomenclature of the winged version of the same gauge is 4253639-01. The orange colour code corresponds to gauge 14G according to standard ISO 10555-5. Within the same manufacturer, the following variants share the family and PUR material but differ in gauge, length or fixation configuration, so they should not be treated as 1:1 interchangeable without assessment of the procedure:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Braun | Introcan Safety-W (winged) G14 PUR | 4253639-01 | Comparable by category (not interchangeable 1:1) | Same gauge G14 (2.2 mm), same length 50 mm and PUR material; incorporates fixation wings for reinforced securing. |
| Braun | Introcan Safety G16 PUR without wings | 4251695-01 | Comparable by category (not interchangeable 1:1) | Same wingless configuration, same PUR material and length 50 mm; smaller gauge G16 (1.7 mm), lower flow rate (210 ml/min). |
| Braun | Vasofix Safety G16 PUR | 4269179S-01 | Comparable by category (not interchangeable 1:1) | Same PUR material and length 50 mm; smaller gauge G16 and different family with retraction/sheathing safety mechanism. |
There is no equivalence table validated by the manufacturer between this catheter and safety systems from other brands; consult with the technical department before use in tenders. Comparable homologous families of wingless safety catheters by category (not 1:1 interchangeable) include: BD Insyte Autoguard Shielded / BD Venflon Pro Safety (shield with button-activated needle retraction, Vialon biomaterial), SafeTouch (Nipro), Surflo (Terumo) and Leaderflex (Vygon). In all cases, gauge, usable length, material, flow rate and safety mechanism must be verified in the manufacturer’s technical data sheet before any substitution; the specific codes of those brands for the G14 size must be confirmed with the manufacturer before use.
5. Selection tips and variants of interest
Always select the smallest gauge that allows the prescribed therapy: this G14 of 50 mm is the highest flow rate option in the wingless family, reserved for adult patients requiring very rapid transfusions, rapid volume expansion, high-viscosity fluids or access in deep veins. If the protocol requires the same size with reinforced fixation, the Introcan Safety-W G14 50 mm winged version (Ref. 4253639-01) is the natural alternative within the same brand. For standard adult therapies, consider G16 (4251695-01) or G18 (4251687-01); for fine-calibre veins or paediatric population, G22 (4251628-01) or G24 (4251601-01 / 4251607-01).
Complete the stock with the obturation mandrels of the Introcan family (e.g. ref. 4214099 for G22) to keep the cannulated line between administrations without risk of occlusion. Always verify the integrity of the packaging and the sterility expiry date before each use, respect aseptic technique and dispose of it after a single use in a sharps container according to the manufacturer’s instructions; the product must not be re-sterilised.