We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Intravenous Safety Catheter Introcan Safety Braun G20 (1.1 × 25 mm) PUR Wingless | Ref. 4251652-01 | Box of 50 units

104,55 €

Safety catheter Introcan Safety Braun G20 (1.1 × 25 mm) in polyurethane (PUR) and wingless presentation: peripheral intravenous access with passive safety mechanism that retracts and shields the needle upon withdrawal, minimising the risk of accidental needlestick. Ideal for injection, infusion and transfusion in adult patients. Sterilised, single-use, in a box of 50 units. Official reference 4251652-01.

International shipping. Import duties and taxes are payable by the recipient.

Reference
4251652-01

Description

1. Introduction

The Catheter SEG G20 1.1 × 25 mm-PUR Introcan Safety Braun (Ref. 4251652-01) is a peripheral intravenous safety catheter that combines the reliability of polyurethane (PUR) with Introcan Safety technology, the most widely adopted passive safety system in hospitalisation. Its wingless design makes it especially easy to handle in free-hand punctures, ensuring fast, stable and protected venous access for both the patient and the healthcare professional.

Indicated for intravenous injection, infusion and transfusion in demanding settings such as emergency departments, hospitalisation, operating theatre or geriatrics, it is supplied sterile and single-use in a box of 50 units.

2. Technical explanation of the system and procedure

The Introcan Safety system integrates a polyurethane (PUR) cannula mounted on a bevelled guide needle. Upon reaching the vein and confirming reflux, the cannula is advanced and the needle is withdrawn: the passive safety mechanism automatically encapsulates the bevel inside a protective chamber and locks it irreversibly, without requiring any additional action from the professional. This eliminates re-exposure to the contaminated needle and drastically reduces the risk of biological needlestick injury, in line with European regulations on the prevention of risks from sharp objects.

With G20 gauge (outer diameter 1.1 mm) and a cannula length of 25 mm, it offers a balanced flow rate for standard intravenous therapies in adults. Polyurethane provides intravascular flexibility, lower thrombogenicity and better tolerance in prolonged access compared with other polymers.

3. Technical Specifications

Manufacturer / Series Braun – Introcan Safety (wingless)
Manufacturer reference 4251652-01
Product type Peripheral intravenous safety catheter
Gauge 20G (external Ø 1.1 mm)
Size (Ø × length) 1.1 × 25 mm
Cannula material Polyurethane (PUR)
Design Without wings
Safety system Passive, with irreversible retraction and shielding of the needle
Connection Female Luer-Lock
Use Intravenous injection, infusion and transfusion
Sterilisation / use Sterile, single-use
Presentation Box of 50 units

4. Equivalences and Cross-References

Reference 4251652-01 corresponds to the Braun Introcan Safety family in its wingless version, G20 gauge and 25 mm length. Within the same manufacturer, the following variants share the family and PUR material but differ in gauge, length or fixation configuration, so they should not be treated as 1:1 interchangeable without assessment of the procedure:

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
Braun Introcan Safety-W (with wings) G20 PUR 4253566-01 Comparable by category (not interchangeable 1:1) Same G20 gauge (1.1 mm) and PUR material; length of 32 mm and incorporates fixation wings.
Braun Introcan Safety wingless G24 PUR 4251601-01 Comparable by category (not interchangeable 1:1) Same wingless configuration and PUR material; smaller G24 gauge (0.7 × 19 mm) for fine-calibre veins and paediatric population.
Braun Introcan Safety wingless G24 PUR 4251607-01 Comparable by category (not interchangeable 1:1) G24 gauge (0.7 × 14 mm); shorter version indicated for neonates and very superficial access.
Braun Introcan Safety-W (with wings) G22 PUR 4253540-01 Comparable by category (not interchangeable 1:1) G22 gauge (0.9 × 25 mm); same length, lower flow rate; with fixation wings.

There is no equivalence table validated by the manufacturer between this catheter and the safety systems of other brands; consult the technical department before use in tenders. As comparable families of wingless safety catheters by category (not 1:1 interchangeable) the following stand out: BD Insyte Autoguard Shielded / BD Venflon Pro Safety (shield with button retraction, Vialon material), SafeTouch (Nipro) and Surflo (Terumo). In all cases, gauge, length, material, flow rate and safety mechanism must be verified in the manufacturer’s technical data sheet before any substitution; their specific codes for wingless G20 could not be verified in public sources and must be confirmed with the manufacturer before use.

5. Selection tips and variants of interest

Always select the smallest gauge that allows the prescribed therapy: this G20 of 25 mm (Ref. 4251652-01) is a balanced option for standard intravenous therapies in adults with free-hand puncture technique. For fine-calibre veins or paediatric population, consider the wingless G24 (4251601-01 of 19 mm or 4251607-01 of 14 mm); if the patient requires reinforced fixation or a winged technique is preferred, the G20 version of 32 mm with wings (4253566-01) or the G22 of 25 mm (4253540-01) are natural alternatives within the same family. For high-flow therapies, go up to G18 gauges or higher.

Complete the stock with the obturation stylets of the Introcan family to keep the line cannulated between administrations without risk of occlusion. Always verify the integrity of the packaging and the sterility expiry date before each use, respect aseptic technique and dispose of it after a single use in a sharp objects container in accordance with the manufacturer’s instructions.

Additional information

Manufacturer

Braun

Family

Introcan Safety

Reference

4251652-01

Gauge

20G

Measurements

1.1 × 25 mm

Material

Polyurethane (PUR)

Design

Without wings

Safety system

Passive, retraction and shielding of the needle

Connection

Female Luer-Lock

Use

Intravenous injection, infusion and transfusion

Sterilisation

Sterile, single-use

Presentation

Box of 50 units