Description
1. Introduction
The Catheter SEG G16 1.7 × 50 mm-PUR Vasofix Safety Braun (Ref. 4269179S-01) is the reference solution for obtaining high-flow peripheral venous access in adult patients: emergency departments, operating theatres, hospitalisation and transfusion services. Its fully automatic passive protection system drastically reduces the risk of accidental needlestick injuries to healthcare personnel, in line with current regulations on sharps handling, without compromising speed or accuracy of cannulation. The 16G gauge (grey colour) is the usual choice for rapid transfusions of blood products, high-viscosity fluids and radiological contrast media.
2. Technical explanation of the procedure
In peripheral intravenous cannulation, the catheter is introduced mounted on a two-way steel needle-cannula that guides advancement through the skin and the venous wall. The Flashback technology allows immediate confirmation of correct positioning by rapid visualisation of blood reflux in the catheter and the needle. The universal cutting bevel (back cut) offers a wide choice of insertion angles with minimal puncture trauma.
Once the vein is cannulated, the needle is withdrawn: the passive safety shield deploys fully automatically covering the tip, eliminating re-exposure and the risk of accidental inoculation. The radiopaque polyurethane (PUR) catheter remains in the vein, flexible and kink-resistant, and its injection port with valve allows intermittent medication administration without puncturing the line, with a closing cap included. The assembly is compatible with standard Luer ports and is latex-free, PVC-free and DEHP-free.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer reference | 4269179S-01 (VASOFIX SAFETY PUR 16G, 1.7 × 50 mm) |
| Family / Brand | Vasofix Safety · B. Braun |
| Gauge | 16G |
| Length | 50 mm |
| Outer diameter | 1.70 mm |
| Connection | Luer-Lock / female connector |
| Material | Radiopaque polyurethane (PUR) |
| Injection port | Yes, with injection valve and closing cap |
| Safety system | Fully automatic passive protection against needlesticks |
| Identification colour | Grey (gauge code 16G, conforming to ISO 10555-5) |
| Sterility / use | Sterile · Single-use |
| Without latex, PVC or DEHP | Yes |
| Device class | Medical device class IIa (EU) · Classification CND C0101010201 |
| Presentation | Box of 50 units |
Complete Vasofix Safety PUR range available in our catalogue:
| Reference | Gauge | Size |
|---|---|---|
| 4269225S-01 | 14G | 2.2 × 50 mm |
| 4269179S-01 (product analysed) | 16G | 1.7 × 50 mm |
| 4269330S-01 | 18G | 1.3 × 33 mm |
| 4269136S-01 | 18G | 1.3 × 45 mm |
| 4269110S-01 | 20G | 1.1 × 33 mm |
| 4269217S-01 | 20G | 1.1 × 25 mm |
| 4269098S-01 | 22G | 0.9 × 25 mm |
| 4269071S-01 | 24G | 0.7 × 19 mm |
4. Equivalences and Cross-References
The reference 4269179S-01 corresponds to the official manufacturer nomenclature B. Braun for the Vasofix Safety PUR catheter in 16G × 50 mm (grey colour), confirmed in the manufacturer’s official catalogue and by authorised distributors. For functional comparison purposes (not interchangeable 1:1), the safety catheters from another brand that most closely match in dimensions are those from BD (Becton Dickinson):
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences |
|---|---|---|---|---|
| BD (Becton Dickinson) | Insyte Autoguard BC (biomaterial Vialon) | 382557 | Comparable by category (not interchangeable 1:1) | Gauge 16G with length 1.77″ (≈45 mm), slightly less than 50 mm; Vialon biomaterial versus radiopaque PUR; button-activated safety versus automatic passive protection; non-integrated injection port. |
| BD (Becton Dickinson) | Insyte Autoguard (Vialon biomaterial) | 381457 | Comparable by category (not interchangeable 1:1) | Gauge 16G with length 1.16″ (≈29.5 mm), clearly less than 50 mm; Vialon biomaterial versus radiopaque PUR; button-activated safety; without integrated injection port. |
On the market there are also equivalent safety lines at category level from manufacturers such as ICU Medical (ProtectIV range), Vygon (Leaderflex), Nipro (SafeTouch) or Smiths Medical (Jelco); their suitability must be confirmed against each manufacturer’s IFU before any substitution. There is no equivalence table validated by the manufacturer that allows 1:1 substitution of this catheter for another brand; consult with the technical department before use in tenders.
5. Selection tips and variants of interest
The 16G gauge (grey colour) offers a very high flow rate with moderate trauma, being the usual choice for rapid transfusions of blood products, high-viscosity fluids, radiological contrast and adult patients with good venous access. For even higher flow rates, consider moving up a gauge within the same Vasofix Safety PUR family (G14); for smaller gauge lines or patients with fragile veins, consider moving down a gauge (G18, G20, G22 or G24).
To maintain catheter patency between administrations, it is recommended to complete the set with the obturator stylet of the corresponding gauge: for this catheter 16G × 50 mm, the Vasofix stylet Ref. 4219171 (16G × 50 mm). Consult your sales representative to configure the combined gauge stock according to the patient profile of your department.




Reviews
There are no reviews yet.