Description
1. Introduction
The Introcan Safety-W Winged Safety Catheter from B. Braun, gauge G16 and size 1.7 × 50 mm (ref. 4253612-01), is the reference solution for achieving safe, rapid, high-flow peripheral venous access in adult and critical patients. It combines the recognised passive safety technology of the Introcan system with a polyurethane (PUR) catheter body, a material that reduces irritation of the venous wall and allows comfortable, stable cannulation even during prolonged access.
It is a single-use, sterile product designed for hospitalisation, emergency departments, operating theatres, transfusion units, haemodialysis and any service where clinical safety and protection of healthcare staff are a priority. Its long 50 mm version makes it especially useful in deep veins or thick subcutaneous tissue, and its G16 gauge guarantees a very high flow rate for therapies requiring high flows.
2. Technical explanation of the equipment and procedure
The Introcan Safety-W catheter is introduced into the vein using a controlled single-step puncture technique. Its hub with fixation wings allows a firm, ergonomic grip, facilitating stabilisation of the assembly during cannulation and subsequent fixation with a dressing.
Once the needle is withdrawn from the catheter, the passive self-activating safety mechanism (protection clip) automatically encapsulates the needle tip within the device, without requiring any additional action from the professional: this eliminates exposure to the contaminated needle and minimises the risk of accidental needlestick injury, in line with European regulations on the prevention of biological accidents (Directive 2010/32/EU).
The polyurethane (PUR) material offers greater intravascular flexibility, lower thrombogenicity and better tolerance during prolonged access. The G16 gauge (outer diameter 1.7 mm) with a length of 50 mm provides a very high flow rate, ideal for rapid transfusions, large-volume infusions, administration of high-viscosity fluids and contrast administration, with a female Luer-Lock connection compatible with standard infusion lines on the market.
3. Technical Specifications
| Characteristic | Specification |
| Manufacturer / Series | B. Braun – Introcan Safety-W (Introcan W Safety) |
| Manufacturer reference | 4253612-01 (INTROCAN SAFETY-W PUR 16G, 1.7X50MM-EU) |
| Product type | Peripheral intravenous safety catheter with wings (winged) |
| Gauge | 16G (outer Ø 1.7 mm) |
| Size (Ø × length) | 1.7 × 50 mm |
| Catheter material | Polyurethane (PUR) |
| Colour code | Grey (ISO 10555-5) |
| Safety system | Passive, auto-activation (needle protection clip) |
| Connection | Female Luer-Lock |
| Design | With fixation wings for stability and fixation |
| Sterilisation / use | Sterile, single-use |
| Presentation | Box of 50 units |
| Main indication | Injection, large-volume infusion and rapid transfusion in adult patients |
Gauge range of the Introcan Safety-W family with wings (B. Braun):
| Reference | Gauge | Size (Ø × length) |
| 4251614-01 | 24G | 0.7 × 14 mm |
| 4253523-01 | 24G | 0.7 × 19 mm |
| 4253540-01 | 22G | 0.9 × 25 mm |
| 4253566-01 | 20G | 1.1 × 32 mm |
| 4253604-01 | 18G | 1.3 × 32 mm |
| 4253590-01 | 18G | 1.3 × 45 mm |
| 4253612-01 | 16G | 1.7 × 50 mm |
| 4253639-01 | 14G | 2.2 × 50 mm |
4. Equivalences and Cross-References
The reference 4253612-01 has been verified in the catalogue of the Introcan family itself from B. Braun as Introcan Safety-W PUR 16G, 1.7 × 50 mm, EU version with wings, so the code is considered valid. The grey colour code corresponds to gauge 16G in accordance with standard ISO 10555-5 (colour coding for intravascular devices).
There is no equivalence table validated by the manufacturer between this catheter and the safety systems of other brands; consult the technical department before use in tenders. Comparable homologous families of winged safety catheters by category (not interchangeable 1:1) include: BD Insyte Autoguard Winged and Venflon Pro Safety (BD, shield with button-activated needle retraction, Vialon material), Surflo W / Surflash W (Terumo), SafeTouch (Nipro) and Leaderflex (Vygon). In all cases, the gauge, usable length, catheter material, flow rate and safety mechanism must be verified in the manufacturer’s technical data sheet before any substitution; their specific codes for G16 could not be verified in public sources and must be confirmed with the manufacturer before use.
Within the same family and manufacturer, the closest variant in flow rate is the Introcan Safety-W G14 of 2.2 × 50 mm (ref. 4253639-01), with maximum flow, and the G18 of 1.3 × 45 mm (ref. 4253590-01) as a high-flow option with a more manageable gauge.
5. Selection tips and variants of interest
Always select the gauge and length according to the venous territory and the type of therapy: this G16 of 50 mm (ref. 4253612-01) is the high-flow option for critical adult patients, rapid transfusions, surgery, large-volume infusion and viscous fluids; if the maximum flow of the family is needed, the G14 variant of 50 mm (ref. 4253639-01) is the alternative; for standard adult therapies, consider G18 (4253604-01 or 4253590-01) or G20 (4253566-01); for fine-gauge veins or paediatric population, use G22 (4253540-01) or G24 (4251614-01 / 4253523-01).
Complete your stock with the 16G 2″ obturation stylet (ref. 4214170) from the Introcan family to keep the cannulated line open between administrations without risk of occlusion. Always verify the integrity of the packaging and the sterility expiry date before each use, follow aseptic technique and dispose of it after a single use in accordance with the manufacturer’s instructions.





Reviews