Description
1. Product Presentation
At Cahnos we offer you the absorbable multifilament suture PREMISUT RAPID of Polyglactin 910 (PGLAR) in Prime quality, a professional reference designed for the supply of operating theatres, purchasing centres and ophthalmic surgery clinics. This presentation incorporates a straight needle with triangular point and conventional cutting of 48 mm (GS48), undyed thread of 75 cm in USP 3/0 gauge and non-grooved surface that slides smoothly through tissue. Predictable behaviour, excellent initial tensile strength, minimal tissue response and reliable knot tying, in a box presentation with 12 units.
2. Technical explanation of the material and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, structured as a multifilament braid that provides flexibility, soft feel and great knot security. Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the thread degrades into substances that the body metabolises without generating relevant tissue reaction.
The RAPID variant (low molecular weight) is optimised for short-term support: it retains 50 % of tensile strength at 5 days and loses 100 % of its resistance at 14 days, with complete absorption between 40 and 45 days. The GS48 straight needle of 48 mm, with triangular point of conventional cutting and non-grooved surface, facilitates penetration into firm tissues with absolute control of the path, being especially suitable for manual suturing on directly accessible surfaces, approximation stitches, superficial continuous sutures, ligatures and ophthalmic surgery procedures.
3. Technical Specifications
3.1. Technical data sheet for reference P2L22GS4830
| Parameter | Specification |
| SKU Cahnos | AMP2L22GS4830 |
| Tariff reference (PREMISUT) | P2L22GS4830 |
| Material | Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant |
| Thread structure | Braided multifilament, non-grooved surface |
| Quality | Prime (PREMISUT RAPID range) |
| Gauge | USP 3/0 (metric 2) |
| Thread length | 75 cm (single strand) |
| Needle shape | Straight |
| Needle tip | Triangular — conventional cutting (conventional cutting) |
| Needle size | GS48 (48 mm) |
| Colour | Colourless |
| Absorption mechanism | By hydrolysis, 40-45 days |
| Sterilisation | Gamma radiation; sterile, single-use, non-resterilizable |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40-45 days, by hydrolysis (predictable and uniform rate) |
3.3. Size equivalence
| USP size | Metric size |
| 3/0 | 2 |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is one of the most widespread categories of multifilament absorbable in the surgical market. At category level, this reference corresponds to braided synthetic absorbable sutures with rapid loss of strength: the closest homologous family is VICRYL RAPIDE™ (Ethicon / Johnson & Johnson MedTech), with the same composition 90 % glycolide / 10 % L-lactide and the same absorption profile of 40-45 days with total loss of strength at 14 days, as well as the ranges Safil Quick and Novosyn Quick (B. Braun) in the segment of rapid-absorption multifilament absorbables.
There is no manufacturer-validated equivalence table that cross-references this specific configuration (straight conventional cutting needle GS48 of 48 mm, USP 3/0 gauge, undyed non-grooved 75 cm thread) with references from other commercial houses; consult the technical department before use in tenders. Any code for VICRYL RAPIDE™ or another brand of rapid-absorption polyglactin 910 should be checked against its technical data sheet and IFU before proposing substitution, since needle nomenclatures, point type (conventional cutting vs reverse cutting) and configuration (single strand vs double strand) vary by manufacturer. The brands cited belong to their respective manufacturers and are mentioned only as a category equivalence reference, not interchangeable 1:1.
5. Selection tips and variants of interest
To choose the correct suture, verify three parameters: USP gauge (this model, USP 3/0, is very versatile and is intended for skin, subcutaneous tissue, mucosa and tissues with moderate tension in short-duration procedures), needle geometry (straight conventional cutting GS48 for direct-access sutures with path control; circular 3/8 or 1/2 variants are reserved for restricted fields) and configuration (single 75 cm strand or double strand for greater yield per unit).
Variants of interest within the Cahnos catalogue: the double-strand version AMP2L22GS4830.2 (GS48, USP 3/0, undyed, 2×75 cm, ref. P2L22RGS4830.2) to optimise performance in the operating theatre; AMP2L22GS4820 (GS48, USP 2/0, undyed, 75 cm) for greater mechanical demand; AMP2L22GS6030 / AMP2L22GS6030.2 (GS60, USP 3/0, undyed, 75 cm and 2×75 cm) for a longer straight needle; AMP222GS4820 (rapid-absorption PGAR, GS48, USP 2/0, undyed) as a material alternative with the same short absorption profile; and P1L28GS4830 (PGLA, GS48, USP 3/0, undyed, 70 cm) when the protocol requires longer support (absorption 56-72 days).
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or enquiries about equivalences from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews