Description
1. Commercial Introduction
The absorbable multifilament polyglycolic acid (PGA) suture from the Prime range of Premisut, reference P118HRT4001-2, is the reference surgical closure solution for hospitals, private operating theatres, clinics and purchasing groups seeking a high-performance absorbable synthetic suture with an excellent price-quality ratio. It features a double needle ½ circle with cylindrical body and trocar point (Tapercut) of 40 mm, USP 1 (metric 4) gauge and fluted violet thread of 70 cm, which guarantees precision, manageability and fully predictable absorption during the first weeks of healing.
Each unit is supplied sterile and ready to use, with the guarantee of professional distribution by Cahnos. Especially indicated for tissue approximation, ligatures and general surgery, where controlled penetration, knot security and minimal tissue reaction are required.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer configured in a braided multifilament structure with a fluted finish, coated with polycaprolactone and calcium stearate. This configuration provides great flexibility, low memory and a contained friction coefficient, which favours the sliding of the thread through tissue, very smooth manageability and a firm and secure knot tying, even in high-diameter gauges such as USP 1.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, without depending on the patient’s enzymatic activity. It maintains 75% of its tensile strength at 2 weeks, 50% at 3 and 40% at 4, an ideal profile for tissues that require wound support for 2 to 4 weeks while they recover their own resistance.
The ½ circle needle with cylindrical body and trocar point (Tapercut profile) combines easy, controlled penetration with a contained cutting effect, making it especially effective in firm, dense tissues (aponeurosis, fascia, muscle planes), minimising trauma to adjacent structures. The double needle format with two 70 cm threads optimises use per pack and is very practical for continuous sutures. The violet colour guarantees optimal visibility in the surgical field. Sterile single-use product, not suitable for re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference AMP118HRT4001-2
| Characteristic | Specification |
|---|---|
| Reference (SKU) | AMP118HRT4001-2 (manufacturer: P118HRT4001-2) |
| Brand / Quality | Premisut – Prime |
| Material | 100% polyglycolic acid (PGA), braided multifilament with fluted finish, coated with polycaprolactone and calcium stearate |
| Gauge | USP 1 (metric 4) |
| Thread colour | Fluted violet (high visibility) |
| Configuration | Double needle, 2 threads of 70 cm per pack |
| Thread length | 70 cm |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Trocar (Tapercut) |
| Needle size | 2xHRT 40 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60-90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single use |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60-90 days (by hydrolysis) |
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is one of the most widely used synthetic absorbable materials in the European market. This reference, by composition (PGA homopolymer), braided structure, polycaprolactone/calcium stearate coating, ethylene oxide sterilisation and absorption by hydrolysis in the 60 to 90 day range, is comparable at category level with the braided multifilament sutures of the main manufacturers. The external references with codes have been checked against the manufacturer’s official catalogue; none is interchangeable 1:1 with the double needle 2xHRT 40 mm of this datasheet:
| Manufacturer / Brand | Line / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| SMI | Surgicryl PGA (polyglycolic acid) | 11400540 | Comparable by category (not interchangeable 1:1) | Same material, USP 1 gauge and HRT 40 mm trocar point, but single needle and 90 cm thread (versus double needle 2×70 cm) |
| Laboratory Aragó | Braided coated P.G.A., TC26 needle | 38044 | Comparable by category (not interchangeable 1:1) | Same 40 mm trocar point, USP 1 gauge and 70 cm thread, but single needle (versus double needle) |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (polyglactin 910) | — | Comparable by category (not interchangeable 1:1) | PGLA copolymer material (not pure PGA) and absorption of 56-72 days; verify needle and presentation |
| B. Braun | Safil (polyglactin 910) | — | Comparable by category (not interchangeable 1:1) | PGLA copolymer material; confirm exact needle geometry and gauge in tender |
| Medtronic / Covidien | Polysorb (absorbable braided range) | — | Comparable by category (not interchangeable 1:1) | PGLA copolymer material; confirm point and double needle configuration |
There is no equivalence table validated by the manufacturer for this reference against the cited commercial houses; consult the technical department before using in tender. Within the Cahnos catalogue, the closest equivalent by needle geometry (2xHRT 40 mm), gauge, colour and length is reference P1L18HRT4001-2 (PGLA Prime) and, in the same PGA material, AM118HRT4001-2 (Normal quality, same double trocar needle 2xHRT 40 mm).
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 1 (metric 4) gauge is indicated for tissues requiring high initial resistance: aponeurosis, fascia, muscle planes and high-tension closures. The trocar point (Tapercut) combines penetration and control in firm tissues; for soft and friable tissues, conical points (HR/Taperpoint) are recommended, and for very delicate structures, reverse cutting points (HS).
| Reference | Recommended variant |
|---|---|
| AMP118HRT4001-2 | PGA Prime USP 1, double trocar needle 2xHRT 40 mm, violet, 70 cm (current product) |
| AM118HRT4001-2 | PGA standard quality USP 1, double trocar needle 2xHRT 40 mm, violet, 70 cm (same geometry, standard range) |
| AMP118HR4001 | PGA Prime USP 1, tapered Taperpoint needle HR 40 mm, violet, 70 cm (more atraumatic for soft tissue) |
| AMP113HR4001 | PGA Prime USP 1, tapered HR needle 40 mm, violet, 90 cm (longer suture length) |
| AMP112HRT4001 | PGA Prime USP 1, trocar HRT needle 40 mm, violet, 75 cm (single needle) |
| P1L18HRT4001-2 | PGLA Prime USP 1, double trocar needle 2xHRT 40 mm, violet, 70 cm (absorption 56-72 days) |
If you require longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos; for faster absorption, consult the rapid absorption range (PGLAR type). All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or equivalents from other commercial brands, contact our technical-commercial team.





Reviews