Description
1. Commercial Introduction
The PGA Prime Multifilament Absorbable Suture with double needle, reference P114DSP6,580-2, is the ultimate precision tool for your operating theatre, ophthalmology unit or purchasing department. It features two ⅜ circle spatula Micropoint needles of 6.5 mm on a braided thread of 100% absorbable polyglycolic acid (PGA), in violet and 30 cm length: the reference format for continuous suturing without rethreading in ophthalmic microsurgery, approximation of delicate lamellar tissues and closure of fine skin.
It is a synthetic, absorbable, sterile, single-use medical device with an excellent value for money for the B2B supply of ophthalmic clinics, operating theatres, distributors and public procurement tenders. Professional presentation in a box of 12 sterile units with batch traceability.
2. Technical Explanation
The thread is made of polyglycolic acid (PGA), a linear-chain synthetic polyester that degrades by hydrolysis with fully predictable kinetics independent of the patient’s enzymatic activity: mass absorption is completed between 60 and 90 days, while tensile strength is maintained during the critical healing phase (75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks).
The polycaprolactone and calcium stearate coating reduces friction and the sawing effect on tissue, improves thread glide and facilitates knot seating with excellent knot security even in gauges as fine as USP 8/0.
The Micropoint DSP 6.5 spatula needle has a flattened profile with lateral cutting edges and a flat lower zone, which separates and displaces the fibres of lamellar tissues (cornea, sclera, conjunctiva, fine skin) rather than cutting them, minimising trauma and the risk of leakage. The double needle (2xDSP 6.5) configuration allows continuous sutures and multiple passes without rethreading, optimising surgical time in reduced working fields. The violet colour ensures immediate visibility on the surgical field. Product sterile by ethylene oxide (EO), single-use, non-reesterilizable and compliant with USP/EP pharmacopoeias for sterile absorbable sutures.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / quality | PREMISUT PRIME (premium range) |
| Factory reference | P114DSP6,580-2 |
| SKU Cahnos | AMP114DSP6,580-2 |
| Thread material | Polyglycolic acid (PGA) 100 % synthetic |
| Structure | Braided multifilament, non-grooved surface (Prime) |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 8/0 (EP metric 0.4); diameter 0.040 – 0.049 mm |
| Needle shape | ⅜ circle (3/8 circular) |
| Tip type | Spatulated Micropoint Spatula (DSP 6.5 Prime profile) |
| Needle size | 2 × 6.5 mm (2xDSP 6.5, double needle) |
| Swaged | Double needle (1 thread with a needle at each end) |
| Thread length | 30 cm |
| Thread colour | Violet |
| Absorption type | By hydrolysis; complete mass absorption in 60-90 days |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Indications | Approximation of soft tissues, ligatures, ophthalmic surgery and microsurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures |
3.2. Tensile strength and absorption profile
| Period | Remaining tensile strength | Absorption |
| 2 weeks | Approximately 75 % | — |
| 3 weeks | Approximately 50 % | — |
| 4 weeks | Approximately 40 % | — |
| 60-90 days | — | Complete absorption by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 9/0 | 0.3 | 0.030 – 0.039 mm |
| 8/0 (this product) | 0.4 | 0.040 – 0.049 mm |
| 7/0 | 0.5 | 0.050 – 0.069 mm |
| 6/0 | 0.7 | 0.070 – 0.099 mm |
4. Equivalences and Cross-References
Reference P114DSP6,580-2 corresponds to the official nomenclature of the PREMISUT PRIME range (2xDSP 6.5 profile: double ⅜ circle spatula Micropoint needle of 6.5 mm, USP 8/0 gauge, 30 cm violet thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or bidding.
There is no manufacturer-validated equivalence table cross-referencing this specific configuration (100% PGA, double 6.5 mm micropoint spatula needle in ⅜ circle, USP 8/0, 30 cm) with references from other brands; the following rows are offered as a functional comparison verified against the manufacturer’s official catalogue or the GUDID/FDA database and must be validated against the IFU before any substitution. As they are another brand, they do not constitute an exact reference equivalence (reserved for the same manufacturer).
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | COATED VICRYL® (polyglactin 910) – MICROPOINT Spatula, TG140-8 of 6.5 mm, 3/8 circle, 8-0, 30 cm, violet braided | J548G | Comparable by category (not interchangeable 1:1) | They match on the 6.5 mm micropoint spatula needle in 3/8 circle, USP 8/0 gauge, 30 cm length, violet colour and braided structure. They differ in material (polyglactin 910 / PGLA vs 100% PGA), coating and absorption kinetics (56-72 days vs 60-90 days); depending on the distribution market, the configuration may be available in a bidirectional version. Code confirmed in GUDID/FDA and official Ethicon catalogue. |
| B. Braun (Aesculap) | SAFIL® Violet – braided and coated PGA, 8/0 (0.4), 30 cm, double DLm6S needle of 6 mm, 3/8 circle micropoint lancet type | G1048710 | Comparable by category (not interchangeable 1:1) | They match on base material (polyglycolic acid), USP 8/0 gauge (EP 0.4), 30 cm length, double needle configuration and violet colour. B. Braun does not use the term ‘spatula’: its functional equivalent is the 6 mm micropoint lancet needle (within ±0.5 mm tolerance over 6.5 mm). They differ in coating (glyconate vs polycaprolactone/calcium stearate) and needle nomenclature. Code confirmed in GUDID/FDA and official B. Braun catalogue. |
| SMI (Steelco Medical Industries) | SURGICRYL® PGA Ophthalmic – side cutting spatula, 2×DSP 6 mm, 8/0, 30 cm, violet | OSU08-30 | Comparable by category (not interchangeable 1:1) | They match on material (braided polyglycolic acid coated with polycaprolactone and calcium stearate), USP 8/0 gauge, 30 cm length, double spatula side-cutting needle configuration, colour scheme and absorption kinetics (60-90 days). They differ in exact needle size (6.0 mm vs 6.5 mm, within ±0.5 mm tolerance). Code confirmed in official SMI datasheet. |
There is no manufacturer-validated equivalence table cross-referencing this specific configuration (100% PGA, double 6.5 mm micropoint spatula needle in ⅜ circle, USP 8/0 gauge, 30 cm thread, Prime quality) with references from other brands; consult the technical department before using in tenders. Copolymer polyglactin 910 (PGLA) ranges, such as Vicryl® (Ethicon), Safil® 910 / Novosyn® (B. Braun) or Polysorb® (Medtronic), are chemically different from PGA homopolymer and must not be treated as 1:1 interchangeable without validation from the pharmacy service or technical department. Other homologous families of braided PGA with spatula needle (Dexon II, ophthalmic ranges from other European suppliers) must be reviewed property by property: material, coating, USP/metric gauge, curvature, point family, needle size and number, thread length, colour and CE/MDR regulatory classification before any substitution. This needle geometry (2xDSP 6.5, USP 8/0, 30 cm, double needle) is only fully safely interchangeable within the PREMISUT system itself.
5. Selection tips and variants of interest
Tissue to suture: USP 8/0 gauge (metric EP 0.4; diameter 0.040-0.049 mm) is the finest gauge commonly used in microsurgery: cornea, sclera and conjunctiva in ophthalmology, fine vascular approximation, closure of fine skin and soft tissues with very low tension. The 6.5 mm micropoint spatula needle in ⅜ circle dissects the tissue plane without cutting it and reduces the risk of leakage.
Double-armed configuration: this 2×30 cm format with a needle at each end is the optimal choice for continuous suturing without rethreading. If your protocol prefers interrupted sutures with a single needle, the same family offers the PGA Prime 8/0 DSP 6.5 mm 30 cm version (SKU AMP114DSP6,580, Ref. P114DSP6,580). For a slightly larger gauge, see the 7/0 45 cm double needle (SKU AMP111DSP6,570-2) or the 7/0 30 cm single needle (SKU AMP114DSP6,570).
Material variants on the same needle: if an absorption profile with polyglactin kinetics is required (56-72 days instead of 60-90 days), the PREMISUT range of Polyglactin 910 offers the same spatulated DSP 6.5 configuration in double-armed 8/0 and 30 cm (SKU P1L14DSP6,580-2). Remember that the polymer composition changes, so it is not interchangeable for indication purposes without clinical validation.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, keep the reference P114DSP6,580-2 together with the batch number for traceability in the operating theatre and store below 30 °C, protected from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.