Description
1. Product Presentation
The Absorbable Multifilament PGA Prime Suture from the PREMISUT range, tariff reference P111DSP6,570-2 (SKU AMP111DSP6,570-2), is the technical solution that your operating theatre, ophthalmology unit or purchasing department needs for high-precision procedures. It combines a braided thread of 100% synthetic polyglycolic acid (PGA) with double ⅜-circle spatulated Micropoint needle of 6.5 mm, USP 7/0 gauge, 45 cm violet strand and non-grooved surface. Supplied in a box of 12 sterile units with batch traceability, it is the reference format for ophthalmic microsurgery, approximation of delicate lamellar tissues and precision closures, as well as for supplier approval processes and public procurement tenders.
2. Technical Explanation
The thread is made from polyglycolic acid (PGA), a linear-chain synthetic polyester that degrades by hydrolysis with fully predictable kinetics independent of the patient’s enzymatic activity: mass absorption is complete between 60 and 90 days, while tensile strength is maintained during the critical healing phase (75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks).
The polycaprolactone and calcium stearate coating reduces friction and the sawing effect on tissue, promotes thread sliding and facilitates knot seating with excellent knot security even in fine gauges such as USP 7/0 (diameter 0.050-0.069 mm).
The Micropoint DSP 6.5 spatulated needle has a flattened profile with lateral cutting edges and a flat lower zone, which separates and displaces the fibres of lamellar tissues (cornea, sclera, conjunctiva, thin skin) rather than cutting them, minimising trauma and the risk of leakage. The double-needle configuration (2xDSP 6.5) allows continuous sutures without rethreading. The violet colour ensures immediate visibility on the surgical field.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / quality | PREMISUT PRIME (premium range) |
| Thread material | Polyglycolic acid (PGA) 100 % synthetic |
| Structure | Braided multifilament, non-grooved surface (Prime) |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 7/0 (metric EP 0.5; diameter 0.050-0.069 mm) |
| Needle shape | ⅜ circle (3/8 circular) |
| Tip type | Spatulated Micropoint Spatula (DSP 6.5 Prime profile) |
| Needle size | 2 x 6.5 mm (2xDSP 6.5, double needle) |
| Swaged | Double needle |
| Thread length | 45 cm |
| Thread colour | Violet |
| Absorption type | By hydrolysis; complete mass absorption in 60-90 days |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmic surgery and microsurgery |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures |
| Presentation | Box of 12 units |
| Manufacturer reference | P111DSP6,570-2 |
| SKU Cahnos | AMP111DSP6,570-2 |
3.2. Tensile strength and absorption profile
| Period | Remaining tensile strength | Absorption |
|---|---|---|
| 2 weeks | Approximately 75 % | — |
| 3 weeks | Approximately 50 % | — |
| 4 weeks | Approximately 40 % | — |
| 60-90 days | — | Complete absorption by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 8/0 | 0.4 | 0.040 – 0.049 mm |
| 7/0 (this product) | 0.5 | 0.050 – 0.069 mm |
| 6/0 | 0.7 | 0.070 – 0.099 mm |
| 5/0 | 1 | 0.10 – 0.149 mm |
4. Equivalences and Cross-References
The reference P111DSP6,570-2 corresponds to the official nomenclature of the PREMISUT PRIME range (profile 2xDSP 6.5: double ⅜-circle spatulated Micropoint needle of 6.5 mm, USP 7/0 gauge, 45 cm violet thread) and Cahnos markets it without altering characters. There is no manufacturer-validated equivalence table cross-referencing this specific configuration (100% PGA, double spatulated micropoint needle of 6.5 mm in ⅜ circle, USP 7/0, 45 cm) with references from other brands; the following rows are offered as a functional comparison verified against the manufacturer’s official catalogue or the GUDID/FDA database and must be validated against the IFU before any substitution. As they are another brand, they do not constitute an exact reference equivalence (reserved for the same manufacturer).
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | COATED VICRYL® (polyglactin 910) – MICROPOINT Spatula, TG140-8 x2 of 6.5 mm, ⅜ circle, 7-0, 45 cm (18″), violet braided | J546G | Comparable by category (not interchangeable 1:1) | They match on the 6.5 mm micropoint spatulated needle in ⅜ circle (double needle), USP 7/0 gauge, 45 cm length, violet colour and braided structure. They differ in material (polyglactin 910 / PGLA vs. 100% PGA), coating and absorption kinetics (56-72 days vs. 60-90 days). Code confirmed in GUDID/FDA and official Ethicon catalogue. |
| B. Braun (Aesculap) | SAFIL® Violet – braided and coated PGA, 7/0 (0.5), 45 cm, double DLM6S needle of 6 mm, ⅜ circle lancet-type micropoint | G1048711 | Comparable by category (not interchangeable 1:1) | They match on base material (polyglycolic acid), USP 7/0 gauge (EP 0.5), 45 cm length, double-needle configuration and violet colour. B. Braun does not use the term ‘spatula’: its functional equivalent is the DLM6S lancet micropoint needle of 6 mm (within ±0.5 mm tolerance over 6.5 mm). They differ in coating (glyconate) and needle nomenclature. Code confirmed in GUDID/FDA. |
| SMI (Steelco Medical Industries) | SURGICRYL® PGA Ophthalmic – side cutting spatula, 2×DSP 6.4 mm, 7/0, 45 cm, violet | OSU072 | Comparable by category (not interchangeable 1:1) | They match on material (braided polyglycolic acid coated with polycaprolactone and calcium stearate), USP 7/0 gauge, 45 cm length, double-needle configuration with lateral-cutting spatulated needle and violet colour. They differ in exact needle size (6.4 mm vs. 6.5 mm, within ±0.5 mm tolerance). Code confirmed in official SMI datasheet and authorised distribution. |
There is no manufacturer-validated equivalence table cross-referencing this specific configuration (100% PGA, 6.5 mm micropoint spatulated needle in ⅜ circle, double needle, USP 7/0 gauge, 45 cm strand, Prime quality) with references from other brands; consult the technical department before use in tenders. Other homologous families of braided polyglycolic acid with spatulated needle — e.g. Dexon II / Safil Quick (standard-release PGA) or Novosyn / Polysorb (PGLA and Lactomer) — must be reviewed property by property (material, coating, USP/metric gauge, curvature, point family, needle size and number, strand length, colour and CE/MDR regulatory classification) before any substitution. This needle geometry (2xDSP 6.5, USP 7/0, 45 cm, double needle) is only safely interchangeable within the PREMISUT system itself.
5. Selection tips and variants of interest
USP 7/0 gauge (metric EP 0.5, diameter 0.050-0.069 mm) is the microsurgery choice for very delicate planes: cornea, sclera and conjunctiva in ophthalmology, fine vascular approximation, closure of thin skin and soft tissues with low tension. The 6.5 mm micropoint spatulated needle in ⅜ circle is the best option for lamellar tissues, where it dissects the plane without cutting it and reduces the risk of leakage.
Double-needle configuration: this 45 cm reference with two needles is the optimal format for continuous suturing without rethreading. If your protocol prefers interrupted sutures with a single needle, the same family offers the PGA Prime 7/0 DSP 6.5 mm 30 cm format (SKU AMP114DSP6,570). For maximum fineness, see the 8/0 gauge with the same DSP 6.5 needle, in single-needle 30 cm (SKU AMP114DSP6,580) or double-needle 30 cm (SKU AMP114DSP6,580-2).
Material variants on the same needle: if an absorption profile with polyglactin kinetics is required (56-72 days instead of 60-90 days), the PREMISUT range of Polyglactin 910 offers the same spatulated DSP 6.5 mounting in 7/0: single needle of 30 cm (SKU P1L14DSP6,570) and double needle of 45 cm (SKU P1L11DSP6,570-2). Remember that the polymer composition changes, so it is not interchangeable for indication purposes without clinical validation.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, keep the reference P111DSP6,570-2 together with the batch number for traceability in the operating theatre and store below 30 °C, protected from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.