Description
1. Product Presentation
The Absorbable Multifilament PGA Prime Suture from the PREMISUT range, reference number P121DSP1150-2, is a high-precision technical solution for B2B supply to operating theatres, ophthalmology clinics, purchasing centres and healthcare distributors. It combines an absorbable synthetic thread of polyglycolic acid (PGA) with a double ⅜-circle needle with a spatulated Micropoint tip of 11 mm, USP 5/0 gauge (metric 1), colourless non-grooved thread of 45 cm and is supplied in a box of 12 units.
This product is indicated for the approximation of delicate tissues, ligatures and closures in general and specialised surgery, with particular suitability for reduced surgical fields where an atraumatic passage and a fully predictable absorption behaviour are required.
2. Technical explanation
Polyglycolic acid (PGA) is an absorbable synthetic polymer presented in a braided multifilament structure with a non-grooved finish and a coating of polycaprolactone and calcium stearate. This configuration reduces the sawing effect, favours the sliding of the thread through the tissue and guarantees excellent knot security even in fine gauges such as USP 5/0 (approximate diameter 0.10-0.149 mm).
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity, completing between 60 and 90 days. The tensile strength retention profile maintains the necessary support during the critical healing phase: 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks.
The spatulated Micropoint needle of ⅜ circle has a flattened design with lateral cutting edges and a flat lower area, ideal for fine, hard and stratified tissues such as the sclera, cornea and mucous membranes. Its profile minimises trauma and controls the depth of the stitch. It is presented in double needle (2xDSP11), which allows continuous sutures to be made without the need for re-threading.
3. Technical Specifications
3.1. General characteristics
| Brand / Range | PREMISUT (Prime quality) |
| Catalogue reference | P121DSP1150-2 |
| SKU Cahnos | AMP121DSP1150-2 |
| Material | 100 % absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament, non-ribbed |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 5/0 (metric 1) |
| Thread colour | Colourless |
| Thread length | 45 cm |
| Needle shape | 3/8 circle (approx. 135°) |
| Tip type | Spatulated Micropoint (atraumatic) |
| Needle size | 2 x 11 mm (2xDSP11 Prime) |
| Absorption mechanism | Hydrolysis, 60-90 days |
| Sterilisation | Ethylene oxide (EtO), single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of tissues, ligatures, general and ophthalmic surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile
| Period | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Complete absorption | 60-90 days by hydrolysis |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 5/0 | 1 | 0.10 – 0.149 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer for this specific configuration (PGA multifilament Prime, double ⅜-circle spatulated Micropoint needle of 11 mm, USP 5/0 gauge, colourless thread of 45 cm); consult the technical department of Cahnos before using in tendering.
Braided coated multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) corresponds to the homologous families of the main manufacturers on the market: pure PGA is the material of the Safil (B. Braun) and Surgicryl (SMI) lines; the Vicryl and Vicryl Rapide (Ethicon) and Polysorb (Medtronic / Covidien) ranges use polyglactin 910, a glycolide-based copolymer comparable by clinical category but not interchangeable 1:1 with pure PGA. As for the needle, the spatulated ⅜-circle geometry is the standard in ophthalmology: Ethicon designates it as micropoint spatula (e.g. GS-9 in Vicryl Rapide for fine gauges), while B. Braun uses its lancet range (DLm / HLm). Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (2 x 11 mm), ⅜ curvature, point family (spatulated), thread length (45 cm) and colour. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
USP 5/0 gauge (metric 1) is indicated for delicate tissues and moderate tension: fine skin, mucous membranes, sclera, cornea and fast-healing planes. The spatulated ⅜-circle needle is recommended when it is necessary to pass through fine and stratified tissues without tearing them, as in ophthalmic surgery, blepharoplasty and precision closures.
| Reference | Variant |
| AMP121DSP1150-2 | PGA Prime, 2xDSP11, USP 5/0, colourless, 45 cm (current product) |
| P1L21DSP1150-2 | Polyglactin 910 (PGLA) Prime, 2xDSP11, USP 5/0, colourless, 45 cm (alternative material with absorption 56-72 days) |
| AMP121XDS1150 | PGA Prime, XDS11 precision needle with square body, USP 5/0, colourless, 45 cm (reverse cutting point) |
| P111DSP6,570-2 | PGA Prime, double spatulated needle 6.5 mm, USP 7/0, violet, 45 cm (finer gauge for microsurgery) |
All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or consultation of additional gauges, lengths and colours on request, contact the technical-commercial team of Cahnos.





Reviews