We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture Polyglactin 910 RAPID Prime | ⅜ Circle Needle Triangular Point Reverse Cutting DS36 (36 mm) · USP 0 (Metric 3.5) · Colourless Thread 75 cm · Box of 12 units (Ref. P2L22DS3610)

Original price was: 43,84 €.Current price is: 34,80 €.

Absorbable multifilament suture of Polyglactin 910 (PGLAR) in Prime quality, RAPID variant with fast and predictable absorption: retains 50% of tensile strength at day 5 and loses it at day 14, with complete reabsorption by hydrolysis between 40 and 45 days. Mounted with ⅜ circle needle with triangular point, reverse cutting, 36 mm (DS36), USP 0 gauge (metric 3.5) and colourless grooved thread of 75 cm. Sterilised by gamma radiation, single-use, with minimal tissue reaction and excellent knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery. Factory ref. P2L22DS3610 · Price per box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22DS3610

Description

1. Commercial Introduction

The absorbable multifilament suture PGLAR Polyglactin 910 RAPID Prime is the accelerated absorption surgical closure reference for general and day surgery operating theatres, ophthalmology departments, emergency services and B2B purchasing centres that need a braided, flexible thread with early and fully predictable strength loss. This presentation mounts a ⅜ circle 36 mm needle with reverse cutting triangular point (DS36), USP 0 gauge and 75 cm undyed ribbed thread: a combination of high initial strength with clean passage through firm tissues, highly valued in tissue approximation, ligatures and ophthalmic surgery. It is supplied in a box of 12 sterile units, with batch traceability and factory reference P2L22DS3610 (SKU AMP2L22DS3610).

2. Technical explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, spun into a braided multifilament structure with a ribbed finish and lubricating coating that promotes thread sliding, very smooth handling and a firm, secure knot in medium gauges such as USP 0. In its RAPID variant (low molecular weight polyglactin 910), absorption occurs by hydrolysis — a predictable process independent of the patient’s enzymatic activity — within 40 to 45 days, retaining 50 % of the initial tensile strength at 5 days and losing it completely at 14 days. This profile makes it especially suitable for rapidly healing superficial tissues (skin closure, mucosa, subcutaneous tissue), small and medium-calibre vessel ligatures and conjunctival suture, in many cases without the need to remove the material.

The ⅜ circle needle (135°) with reverse cutting triangular point penetrates firm, unyielding tissues with a clean, controlled passage, minimising tearing of the wound edge. The product is sterilised by gamma radiation, is single-use and non-resterilisable: check the integrity of the packaging and the expiry date before each procedure.

3. Technical Specifications

3.1. General characteristics (Ref. P2L22DS3610 · SKU AMP2L22DS3610)

Parameter Specification
Material Polyglactin 910 (PGLAR): copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant
Thread structure Braided multifilament with ribbed finish and coating
Quality Prime (PREMISUT RAPID range)
Gauge USP 0 (metric 3.5)
Thread colour Colourless (undyed)
Thread length 75 cm
Needle shape ⅜ circle (3/8, 135°)
Needle body and point Triangular reverse cutting (reverse cutting), size DS36 (36 mm)
Absorption mechanism Hydrolysis
Absorption period 40 – 45 days
Tensile strength retention 50 % at 5 days / 0 % at 14 days
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units (minimum order 30 boxes)
Factory reference P2L22DS3610
SKU Cahnos AMP2L22DS3610

3.2. Absorption profile and tensile strength retention

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Complete absorption 40 – 45 days by hydrolysis (predictable and uniform rate)

Absorption by hydrolysis with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable absorption rate. The cited profile corresponds to the RAPID formulation; it should not be confused with standard polyglactin 910 (PGLA line, absorption 56 – 72 days).

4. Equivalences and Cross-References

Rapid absorption polyglactin 910 (low molecular weight) is the most widespread rapid-action braided multifilament absorbable category in the surgical market, whose international clinical benchmark is the VICRYL RAPIDE line from Ethicon (Johnson & Johnson MedTech). This reference shares material, accelerated absorption profile (≈42 days), tensile retention (50 % at 5 days / 0 % at 14 days), ⅜ circle curvature, reverse cutting point and undyed colour with that segment, but for the exact combination USP 0 / 36 mm reverse cutting triangular needle (DS36) / 75 cm undyed thread, no code from another manufacturer has been found in official catalogues that meets all attributes: the public codes of VICRYL RAPIDE with a 36 mm reverse cutting needle correspond to USP 2/0 gauge (e.g. W9961, 75 cm, box of 12, verified in authorised distribution), so they are not interchangeable 1:1 with this reference in USP 0 gauge. Nor is VICRYL RAPIDE USP 0 with a ½ circle TAPERCUT needle (e.g. W9963, 90 cm) comparable, due to differences in curvature and point type.

Comparable ranges in the rapid absorption segment include Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category, material and absorption profile; for the exact combination USP 0 / DS36 reverse cutting needle / 75 cm undyed thread, their specific codes must be confirmed with each manufacturer. Standard VICRYL (absorption 56 – 72 days) is not comparable to this RAPID version.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders, verifying in each official data sheet the USP 0 gauge (metric 3.5), the ⅜ circle curvature, the needle type and size (reverse cutting triangular 36 mm), the thread length (75 cm) and the undyed colour.

5. Selection tips and variants of interest

The USP 0 gauge (metric 3.5) with ⅜ circle 36 mm reverse cutting triangular point needle offers high initial strength with clean passage through firm tissues, indicated for tissue approximation, ligatures and ophthalmic surgery. If the service prefers to reduce cost per suture, consider the same assembly in double strand format 2×75 cm (SKU AMP2L22DS3610.2). Within the same PGLAR Polyglactin 910 RAPID range with ⅜ circle reverse cutting needle, Cahnos offers complementary configurations: the same DS36 needle in USP 2/0 gauge (SKU AMP2L22DS3620), the DS26 needle in USP 3/0 (SKU AMP2L22DS2630) and the Normal quality version with the same needle and gauge (SKU AM2L22DS3610). For a longer tensile support profile, consider the PGLA family of standard polyglactin 910 (absorption 56 – 72 days). The undyed version offers maximum discretion in the field; if greater visibility is required, request the same configuration in dyed thread on demand.

As this is a sterile single-use product, store it in a cool, dry place, protected from sunlight, and check the integrity of the packaging and the expiry date before each procedure. For special B2B conditions, volume orders or equivalents from other commercial brands, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR): copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant

Thread structure

Braided multifilament with ribbed finish and coating

Quality

Prime (PREMISUT RAPID range)

Gauge

USP 0 (metric 3.5)

Needle shape

⅜ circle (3/8, 135°)

Needle type and size

Reverse cutting triangular, DS36 (36 mm)

Absorption mechanism

Hydrolysis

Sterilisation

Gamma radiation, single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Manufacturer reference

P2L22DS3610

Medida de aguja

DS 36

Usp

0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture Polyglactin 910 RAPID Prime | ⅜ Circle Needle Triangular Point Reverse Cutting DS36 (36 mm) · USP 0 (Metric 3.5) · Colourless Thread 75 cm · Box of 12 units (Ref. P2L22DS3610)”