Description
1. Introduction
The Absorbable Multifilament PGA Prime Suture in its double-needle version is the choice of professionals seeking cutting precision, manageability and fully predictable resorption. Designed for general, plastic and cosmetic surgery procedures, this suture combines the reliability of polyglycolic acid with a precision needle with a square body, designed for clean passage through fine and delicate tissues without compromising hold. It is presented in a box of 12 units with factory reference P111XDS1350-2, ready for continuous supply to operating theatres and purchasing centres.
2. Technical Explanation
The suture is composed of 100% polyglycolic acid (PGA) braided into a multifilament with a non-grooved finish, providing flexibility, excellent knot strength and smooth handling. The polycaprolactone and calcium stearate coating reduces friction as it passes through tissue and improves thread glide, minimising tissue trauma and sawing effect.
Its absorption occurs by hydrolysis, a predictable physiological process independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, which is metabolisable by the body, maintaining the necessary strength during the first weeks of healing. The ⅜ circle needle with precision reverse cutting triangular point and square body, 13 mm (XDS13) offers prolonged sharpness with a geometry designed for plastic and cosmetic tissues, avoiding tearing. The double-needle (2x) format allows continuous sutures or mirror stitches with a single 45 cm thread, optimising time and consumption in the operating theatre. Product sterile by ethylene oxide, single-use and non-reesterilisable.
3. Technical Specifications
3.1. General characteristics
| Composition | 100% multifilament polyglycolic acid (PGA), absorbable by hydrolysis |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Non-grooved braided multifilament |
| Absorption | Complete between 60 and 90 days |
| Strength retention | 75 % at 2 weeks · 50 % at 3 weeks · 40 % at 4 weeks |
| Sterility | Ethylene oxide, minimal tissue reaction, single-use |
| Commercial presentation | Box of 12 units |
| Regulatory standard | Conforms to USP and European Pharmacopoeia (EP) gauges |
3.2. Reference configuration
| USP size | Thread length | Colour | Swaged | Needle | Factory reference |
|---|---|---|---|---|---|
| 5/0 (metric 1) | 45 cm | Violet | Double needle (2x) | XDS13 mm · ⅜ circle · precision reverse cutting with square body | P111XDS1350-2 |
Indicative thread diameter USP 5/0: 0.10 – 0.149 mm according to USP/European Pharmacopoeia. Indicated for tissue approximation, ligatures and general surgery, particularly suitable for plastic and cosmetic surgery due to its precision needle.
4. Equivalences and Cross-References
The XDS13 model with square body and extra precision reverse cutting is a specific geometry of the Prime line. The existence of products from other manufacturers with the same gauge (5/0), length (45 cm), colour (violet), curvature (⅜), 13 mm needle and point family (triangular reverse cutting) has been verified in public sources and regulatory databases, although with standard needle geometry instead of the extra precision cutting with square body. They are therefore classified as comparable by category, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| DemeTECH | DemeSORB | PGA185013F4P | Comparable by category (not interchangeable 1:1) | Braided coated PGA, DC-3 needle 13 mm ⅜ circle reverse cutting, USP 5/0, 45 cm, violet, box of 12. Standard reverse cutting needle compared to the extra precision cutting with square body XDS. |
| RESORBA | PGA-RESORBA | PA1159 | Comparable by category (not interchangeable 1:1) | Braided coated PGA, DSM-13 needle 13 mm ⅜ circle reverse cutting, USP 5/0, 45 cm, violet. Presentation of 24 units; standard needle, not precision with square body. |
| AD Surgical | UNIFY PGA | S-G518R13 | Comparable by category (not interchangeable 1:1) | Absorbable braided PGA, 13 mm ⅜ circle reverse cutting needle (P-3 / P-13), USP 5/0, 45 cm, violet, box of 12. Standard needle compared to the extra precision cutting. |
| Ethicon | Coated VICRYL (polyglactin 910) | J463G | Comparable by category (not interchangeable 1:1) | Braided coated, P-3 needle 13 mm ⅜ circle reverse cutting, USP 5/0, 45 cm, violet, box of 12. PGLA polymer (glycolide-lactide copolymer), not pure PGA, with a shorter absorption profile. |
There is no equivalence table validated by the manufacturer declaring these cross-references as interchangeable 1:1; the codes cited have been verified in catalogues and shops of authorised distributors and in the GUDID/FDA registry for DemeSORB (UDI 10652927181354). Before substituting this reference in a tender, check one by one: material, USP gauge, needle size (13 mm), curvature, point family, thread length and colour. Consult the technical department before using in tendering or direct substitution. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
For very fine tissues (skin, mucosa, facial areas), gauges 5/0 or 6/0 with a short needle are recommended; this 5/0 suture with a 13 mm needle is ideal for precision closures in plastic and cosmetic surgery. If a colourless thread is preferred to avoid visible dye, there is a colourless version of the same family (single XDS13 needle, USP 5/0, 45 cm); XDS needles of other lengths (8, 11, 16 and 19 mm) and gauges 6/0, 4/0 and 3/0 are also available. Within the Cahnos catalogue, the same XDS13 double-needle configuration in polyglactin 910 (PGLA) corresponds to reference P1L11XDS1350-2, with shorter absorption (56-72 days). Always verify the configuration (with or without double needle) and point geometry according to the tissue to be sutured before formalising the order in tendering.





Reviews