Description
1. Commercial Introduction
The absorbable multifilament suture of polyglycolic acid (PGA) from the Premisut range, reference AM118HRT4001-2 (manufacturer reference: 118HRT4001-2), is the reference surgical closure solution for hospitals, private operating theatres, clinics and purchasing centres seeking a high-performance synthetic absorbable thread with excellent value for money. It features a double ½-circle needle with cylindrical body and trocar point (Tapercut) 40 mm, USP 1 (metric 4) gauge, with violet fluted thread 70 cm.
Each unit is supplied sterile and ready to use, with the assurance of professional distribution by Cahnos. Especially indicated for tissue approximation, ligatures and general surgery, where controlled penetration, knot security and minimal tissue reaction are required. It is presented in a box of 12 units with a minimum order of 30 boxes, ensuring continuous and traceable supply for your healthcare facility.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer configured in a braided multifilament structure with a fluted finish, coated with polycaprolactone and calcium stearate. This configuration provides high flexibility, low memory and a contained coefficient of friction, which favours thread glide through tissue, very smooth handling and firm, secure knot tying, even in high-diameter gauges such as USP 1.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 and 40% at 4, an ideal profile for tissues requiring wound support for 2 to 4 weeks while they regain their own strength.
The ½-circle needle with cylindrical body and trocar point (Tapercut profile) combines easy, controlled penetration with a contained cutting effect, making it especially effective in firm, dense tissues (aponeurosis, fascia, muscle planes), minimising trauma to adjacent structures. The double-needle format with two 70 cm threads optimises use per package and is very practical for continuous sutures. The violet colour ensures optimal visibility in the surgical field. Sterile single-use product, not suitable for re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference AM118HRT4001-2
| Characteristic | Specification |
|---|---|
| Reference (SKU) | AM118HRT4001-2 (manufacturer: 118HRT4001-2) |
| Brand / Quality | Premisut – Normal quality |
| Material | 100 % polyglycolic acid (PGA), braided grooved multifilament, coated with polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament with grooved finish (grooved) |
| Gauge | USP 1 (metric 4) |
| Thread colour | Violet (high visibility) |
| Configuration | Double needle, 2 threads of 70 cm per pack |
| Thread length | 70 cm |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Trocar (Tapercut) |
| Needle size | 2xHRT 40 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60-90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60-90 days (by hydrolysis) |
Predictable and uniform absorption profile in accordance with USP/EP Pharmacopoeia for synthetic absorbable sutures, with minimal tissue reaction, excellent tensile strength and optimal knot tying.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is one of the most widely used synthetic absorbable materials in the European market. By composition (PGA homopolymer), braided structure, polycaprolactone/calcium stearate coating, ethylene oxide sterilisation and hydrolysis absorption in the 60 to 90 day range, this reference is comparable at category level with the braided multifilament sutures of the main manufacturers. However, the configuration of this product (double needle 2xHRT 40 mm, USP 1 gauge, violet 70 cm thread) has no verified 1:1 correspondence in the official catalogues of other brands, so no external reference meets all the criteria (material, gauge, double-needle assembly, curvature and point family) to be listed as interchangeable.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| SMI | Surgicryl PGA (braided polyglycolic acid) | 11400540 | Comparable by category (not interchangeable 1:1) | Same material (PGA), USP 1 gauge and HRT 40 mm trocar point, but single needle and 90 cm thread (versus double needle 2×70 cm). |
| Laboratory Aragó | Braided coated P.G.A., TC26 needle | 38044 | Comparable by category (not interchangeable 1:1) | Same 40 mm trocar point, USP size 1 and 70 cm thread, but single needle (as opposed to double needle). |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (polyglactin 910) | — | Comparable by category (not interchangeable 1:1) | PGLA copolymer material (not pure PGA) and absorption of 56-72 days; verify needle and presentation. |
| B. Braun | Safil (polyglactin 910) | — | Comparable by category (not interchangeable 1:1) | PGLA copolymer material; confirm exact needle geometry and size in tender. |
| Medtronic / Covidien | Polysorb (absorbable braided range) | — | Comparable by category (not interchangeable 1:1) | PGLA copolymer material; confirm point and double-needle configuration. |
There is no equivalence table validated by the manufacturer for this reference against the commercial brands cited; consult the technical department before use in tenders.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 1 (metric 4) gauge is indicated for tissues requiring high initial strength: aponeurosis, fascia, muscle planes and high-tension closures. The trocar point (Tapercut) combines penetration and control in firm tissues; for soft and friable tissues, conical points (HR/Taperpoint) are recommended, and for very delicate structures, reverse cutting points (HS).
| Reference | Recommended variant |
|---|---|
| AM118HRT4001-2 | PGA USP 1, double trocar needle 2xHRT 40 mm, violet, 70 cm (current product) |
| AMP118HRT4001-2 | PGA Prime USP 1, double trocar needle 2xHRT 40 mm, violet, 70 cm (higher range, same geometry) |
| AM118HR4001 | PGA USP 1, conical Taperpoint HR 40 mm needle, violet, 70 cm (more atraumatic) |
| AM113HR4001 | PGA USP 1, conical HR 40 mm needle, violet, 90 cm (longer thread length) |
| AM112HRT4001 | PGA USP 1, trocar HRT 40 mm needle, violet, 75 cm (single needle) |
| 1L18HRT4001-2 / P1L18HRT4001-2 | PGLA (polyglactin 910) USP 1, double trocar needle 2xHRT 40 mm, violet, 70 cm (absorption 56-72 days) |
If you need longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos; for faster absorption, consult the fast-absorption range (PGLAR type). All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare facility. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial brands, contact our technical-commercial team.





Reviews