We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · Needle 3/8 Circle Triangular Point Reverse Cutting 19 mm (DS19) · USP 3/0 · Colourless · Double Thread 2×75 cm · Box 12 Units

84,84 €

Absorbable multifilament suture PGLAR Polyglactin 910 RAPID in Prime quality, with a ⅜ circular needle with a reverse cutting triangular point of 19 mm (DS19 profile), USP gauge 3/0 (metric 2) and colourless grooved thread in a presentation of 2 threads of 75 cm. Absorption by hydrolysis in 40–45 days: retains 50 % of tensile strength at 5 days and loses it completely at 14 days. Sterilised by gamma radiation, single-use, with minimal tissue reaction and excellent knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P2L22DS1930.2 · Price per box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22DS1930.2

Description

1. Commercial Introduction

The Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID in Prime quality (PREMISUT RAPID range) is the accelerated absorption surgical closure solution for hospitals, general and ambulatory surgery operating theatres, emergency departments and ophthalmology and minor surgery clinics. Its ⅜ circle needle with reverse cutting triangular point of 19 mm ensures clean penetration in fine and firm tissues, while the double thread presentation (2 × 75 cm) maximises performance per unit: two mounted strands, ready for two consecutive sutures. A cost-effective and predictable option for B2B purchasing centres, with a box of 12 units.

2. Technical Explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, spun into a braided multifilament structure with a coating and grooved finish that favours thread sliding, smooth handling and a firm, secure knot.

In the RAPID variant (low molecular weight polyglactin 910), the thread loses tensile strength in an accelerated and programmed manner: it retains 50 % of the initial resistance at 5 days and 0 % at 14 days, with complete absorption by hydrolysis between 40 and 45 days. This profile makes it especially suitable for superficial tissues with rapid healing (skin closure, mucous membranes, subcutaneous tissue), ligation of small-calibre vessels and conjunctival suture in ophthalmic surgery.

The reverse cutting needle directs the cutting edge away from the wound, generating a clean entry hole that preserves the skin edge and avoids enlarging the cut in the puncture bed. Prime quality ensures consistency of sharpening and finish batch to batch. Sterile single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics (Ref. P2L22DS1930.2 · SKU AMP2L22DS1930.2)

Parameter Specification
Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant
Thread structure Braided coated multifilament, fluted finish
Quality Prime (PREMISUT RAPID range)
Gauge USP 3/0 (metric 2)
Thread diameter 0.20 – 0.249 mm (indicative, according to Pharmacopoeia)
Thread colour Colourless
Thread length 2 × 75 cm (2 strands of 75 cm per unit)
Needle shape 3/8 circle (⅜ circular)
Needle tip Triangular, reverse cutting (reverse cutting), triangular body and point
Needle size DS 19 mm (Prime)
Swaged Double suture: 1 needle per strand, 2 strands per unit
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Commercial format Box of 12 units
Factory reference P2L22DS1930.2 · SKU Cahnos AMP2L22DS1930.2

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 40 – 45 days
Tensile strength at 5 days 50% of initial strength
Tensile strength at 14 days 0% (total loss of tensile support)
Absorption rate Predictable and uniform

3.3. Gauge equivalence (USP Pharmacopoeia)

USP size Metric size Approximate diameter
3/0 (this product) 2 0.20 – 0.249 mm
4/0 1.5 0.15 – 0.199 mm
2/0 3 0.30 – 0.339 mm

3.4. Reference code decoding

The official reference P2L22DS1930.2 breaks down as follows: P (Prime range) + 2L22 (75 cm thread in the PGLAR family) + DS19 (⅜ circle needle with classic reverse cutting triangular point of 19 mm, triangular body and point) + 30 (USP 3/0 gauge) + .2 (double presentation, 2 threads of 75 cm). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or bidding.

4. Equivalences and Cross-References

Rapid absorption polyglactin 910 (low molecular weight) is the most widespread absorbable multifilament category in the surgical market, whose international clinical benchmark is the VICRYL RAPIDE line from Ethicon (Johnson & Johnson MedTech), with which it shares composition, hydrolysis absorption mechanism and accelerated resistance loss profile. This reference shares with homologous lines the material, the ⅜ circle curvature, the 19 mm reverse cutting needle and the undyed thread. The following only includes codes whose attributes have been verified in the manufacturer’s official catalogue and authorised distributors; none of these references should be considered interchangeable 1:1 without validation from the technical department.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) VICRYL RAPIDE (polyglactin 910, braided, colourless) W9922 – USP 4/0, ⅜ circle reverse cutting needle 19 mm, undyed thread 75 cm Comparable by category (not interchangeable 1:1) Same material and absorption profile; same needle configuration (19 mm, ⅜ circle, reverse cutting) but USP 4/0 gauge versus 3/0 and presentation of 1 thread of 75 cm versus 2 × 75 cm. Code verified in authorised distributors.
Ethicon (J&J MedTech) VICRYL RAPIDE (polyglactin 910, braided, colourless) W9932 – USP 3/0, PS needle ⅜ circle reverse cutting, undyed 75 cm thread Comparable by category (not interchangeable 1:1) Same material, USP 3/0 gauge, 75 cm length and undyed colour; differs in needle profile size (PS versus DS19) and presentation (1 × 75 cm versus 2 × 75 cm). Code verified in authorised distributors.
B. Braun / Aesculap Safil Quick (low molecular weight polyglycolic acid, braided and coated) C0046629 – USP 4/0, ⅜ circle reverse cutting needle with micro-point (DSMP) of 19 mm, undyed thread of 45 cm Comparable by category (not interchangeable 1:1) Same ⅜ circle curvature and 19 mm reverse cutting needle; differs in base material (polyglycolic acid versus polyglactin 910), gauge (4/0 versus 3/0), needle profile (DSMP versus DS) and presentation. Code verified in authorised distribution.

There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before using in tendering. Homologous ranges in the rapid absorption segment include Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category by material and absorption profile, although for the exact combination USP 3/0 / DS 19 mm needle / 2 × 75 cm their specific codes must be confirmed with the manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.

5. Selection tips and variants of interest

USP 3/0 gauge (metric 2) is a common choice in skin, mucous membranes, subcutaneous tissue, paediatrics and procedures with healing from 5 to 10 days where short-term tensile support and early absorption are required: conjunctival and ophthalmic suture, mucosal approximation, ligation of small vessels and minor surgery. The 19 mm ⅜ circle reverse cutting needle is especially recommended when a firm and precise passage through the skin or mucous membranes is required without tearing the edge.

Within the same PGLAR Polyglactin 910 RAPID range, Cahnos offers complementary configurations to adjust the reference to the protocol:

Reference Variant
AMP2L22DS1930.2 (P2L22DS1930.2) PGLAR RAPID Prime, DS 19 reverse cutting needle, USP 3/0, undyed, 2 × 75 cm (this product)
AMP2L22DS1930 (P2L22DS1930) PGLAR RAPID Prime, same needle and gauge, single 75 cm thread
AMP2L22DS1940 (P2L22DS1940) PGLAR RAPID Prime, DS 19 needle, USP 4/0, undyed, 75 cm (finer gauge)
AMP2L22DS1950 (P2L22DS1950) PGLAR RAPID Prime, DS 19 needle, USP 5/0, undyed, 75 cm (for very fine tissues)
AM2L22DS2630 (2L22DS2630) PGLAR RAPID, DS 26 needle, USP 3/0, undyed, 75 cm (longer needle for firmer tissues)
AMP2L21DS1940FN (P2L21DS1940FN) PGLAR RAPID Prime, DS 19 needle, USP 4/0, undyed, 45 cm, fine profile (FN)

The colourless version offers maximum aesthetic discretion in the surgical field; if greater visibility is required, request the same configuration in dyed thread on demand. Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Material

Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide), RAPID variant

Structure

Multifilament braided fluted

USP size

3/0 (metric 2)

Thread diameter

0.20 – 0.249

Thread length

2 x 75 cm (double thread)

Needle tip

Triangular reverse cutting (reverse cutting)

Quality

Prime (PREMISUT RAPID)

Sterilisation

Gamma radiation

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units

Manufacturer reference

P2L22DS1930.2

Medida de aguja

DS 19

Usp

3/0

Color

Colourless

Medida de hilo

2 × 75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · Needle 3/8 Circle Triangular Point Reverse Cutting 19 mm (DS19) · USP 3/0 · Colourless · Double Thread 2×75 cm · Box 12 Units”

Your email address will not be published. Required fields are marked *