We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture · Double ½ Circle Spatula Micropoint Needle 7 mm (2×HSP 7) · USP 8/0 Violet · 30 cm · Box of 12 units · Ref. P114HSP780-2

Original price was: 301,23 €.Current price is: 207,90 €.

100% polyglycolic acid (PGA) absorbable multifilament suture in USP 8/0 gauge (metric EP 0.4), Prime quality (PREMISUT), mounted with a double ½ circle spatula Micropoint needle of 7 mm (2×HSP 7 format). Violet non-crimped thread of 30 cm with a coating of polycaprolactone and calcium stearate, which favours glide and knot security. Predictable absorption by hydrolysis in 60-90 days, with tension retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterilised by ethylene oxide, single-use and not to be resterilised, in a box of 12 individual pouches. Indicated for approximation of soft and laminar tissues, ligatures and general precision surgery. Manufacturer’s ref. P114HSP780-2 · SKU AMP114HSP780-2.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP114HSP780-2

Description

1. Product Presentation

The PGA Prime Multifilament Absorbable Suture from the PREMISUT range, tariff reference P114HSP780-2, is the precision solution that your operating theatre, purchasing department or microsurgery unit needs for procedures requiring maximum fineness and fully predictable behaviour. It features a double ½-circle spatulated Micropoint needle of 7 mm (2×HSP 7 Prime format) on a braided thread of 100 % absorbable polyglycolic acid (PGA), in violet and 30 cm of strand, with a non-grooved surface. Professional presentation in a box of 12 sterile units with batch traceability, ideal for supplier approval, public procurement tenders and hospital supply agreements.

2. Technical Explanation

The thread is made of polyglycolic acid (PGA), a linear-chain synthetic polyester that degrades by hydrolysis with predictable kinetics independent of the patient’s enzymatic activity: mass absorption is complete between 60 and 90 days, while tensile strength is maintained during the critical healing phase (≈75 % at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks). The polycaprolactone and calcium stearate coating reduces friction and the sawing effect on tissue, improves thread glide and facilitates knot seating, with excellent knot security and minimal tissue reaction.

The ½-circle spatulated Micropoint needle has a flat lateral edge that separates and displaces the fibres of delicate lamellar tissues (cornea, conjunctiva, sclera, fine skin) rather than cutting them, minimising trauma and the risk of leakage. The Prime finish (non-grooved surface) optimises passage through tissue. Its double-needle format (one at each end of the thread) allows continuous sutures to be run without rethreading and a more balanced distribution of tension. The USP 8/0 gauge (EP metric 0.4) is one of the finest precision suture thicknesses and the violet colour ensures immediate visibility on the surgical field. Product sterile by ethylene oxide (EO), single-use, non-reesterilizable and conforming to USP/EP pharmacopoeias for sterile absorbable sutures.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / quality PREMISUT PRIME (premium range of multifilament suture)
Thread material Polyglycolic acid (PGA) 100 % synthetic
Structure Braided multifilament, non-grooved surface (Prime)
Coating Polycaprolactone and calcium stearate
Absorption type By hydrolysis; complete mass absorption in 60-90 days
Gauge / size USP 8/0 (metric EP 0.4)
Thread diameter 0.040 – 0.049 mm (USP/EP Pharmacopoeia)
Needle shape ½ circle (1/2 circular)
Tip type Spatulated Micropoint Spatula (profile 2×HSP 7 Prime)
Needle size 2 × 7 mm (double needle, format 2×HSP 7)
Swaged Double needle (one at each end of the thread)
Thread length 30 cm
Thread colour Violet (the range is also available in undyed)
Sterilisation Ethylene oxide (EO); single-use, not re-sterilisable
Indications Approximation of soft and laminar tissues, ligatures, microsurgery and general precision surgery
Commercial presentation Box of 12 units (individual sterile sachets)
Storage Below 30 °C, protected from moisture and direct sunlight
Regulatory standard Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures
Factory reference P114HSP780-2
SKU Cahnos AMP114HSP780-2

3.2. Tensile strength and absorption profile

Period Remaining tensile strength Absorption
2 weeks Approximately 75 % —
3 weeks Approximately 50 % —
4 weeks Approximately 40 % —
60-90 days — Complete absorption by hydrolysis

3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
9/0 0.3 0.030 – 0.039 mm
8/0 (this product) 0.4 0.040 – 0.049 mm
7/0 0.5 0.050 – 0.069 mm
6/0 0.7 0.070 – 0.099 mm

4. Equivalences and Cross-References

The reference P114HSP780-2 corresponds to the official nomenclature of the PREMISUT PRIME range (HSP 7 profile: 7 mm spatulated Micropoint needle in ½ circle, USP 8/0 gauge, 30 cm violet thread, double-needle configuration) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Braided polyglycolic acid with a precision spatulated needle is one of the most standardised absorbable suture families on the market. However, there is no manufacturer-validated equivalence table cross-referencing this specific configuration (100 % PGA, USP 8/0, double ½-circle spatulated needle of 7 mm, 30 cm violet strand, Prime quality) with references from other houses; consult the Cahnos technical department before use in tendering. The only cross-references with verified codes in official sources or authorised distributors are listed below as functional comparisons (not 1:1 interchangeable), since they alter some key field (polymer, curvature or needle size):

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) COATED VICRYL®, braided polyglactin 910, violet, 8-0, 30 cm, double-armed, reverse spatula needle 7 mm, ½ circle J9564G Comparable by category (not interchangeable 1:1) Code confirmed in official Ethicon EPC and authorised distributors. Needle geometry (½ circle, 7 mm, spatulated), gauge, colour, length and double configuration match; but the material is polyglactin 910 (copolymer) versus 100 % PGA, with absorption 56-70 days: it is not an exact reference equivalent.
Medtronic (Covidien) POLYSORB™, lactomer (glycolide/lactide copolymer) braided coated, 8-0, 30 cm (12″), violet, premium spatulated needle SE-160-8, ½ circle L2749K Comparable by category (not interchangeable 1:1) Code located in authorised distributors (Efficient Medical, Proclinic). Same gauge, colour, length and ½ spatulated curvature; lactomer material versus pure PGA and exact needle size to be confirmed in IFU before substitution.
SMI (Steinberg Medical Instruments) Surgicryl® PGA Ophthalmic, braided coated PGA (polycaprolactone + calcium stearate), 8/0, 30 cm, violet, double side-cutting spatulated needle OSU08-30 Comparable by category (not interchangeable 1:1) Confirmed in unofficial SMI catalogue. Same material (PGA), coating, gauge, colour and length; but 3/8 circle needle 2×DSP 6 mm versus ½ circle 2×HSP 7 mm: different curvature and size, requires clinical validation of the protocol.

Other homologous families of braided absorbable suture with precision spatulated needle —B. Braun Safil® (PGA, micropoint lancet needle in its ophthalmic range), Dexon II (PGA) and Assut Assucryl® (PGA)— must be reviewed property by property (material, coating, USP/metric gauge, curvature, point family, size and number of needles, strand length, colour and CE/MDR regulatory classification) before any substitution, since their manufacturers do not publish in the sources consulted a verified 8/0 code with ½-circle 7 mm spatulated needle. This needle geometry (HSP 7, USP 8/0, 30 cm, double needle) is only safely interchangeable within the PREMISUT system itself. There is no manufacturer-validated equivalence table; consult the technical department before use in tendering.

5. Selection tips and variants of interest

The USP 8/0 gauge (EP metric 0.4, diameter 0.040-0.049 mm) with double 7 mm spatulated needle in ½ circle is the usual choice for approximating delicate lamellar tissues, microsurgery and precision surgery; the spatulated point dissects the plane without cutting it and reduces the risk of leakage. In the same ½-circle spatulated family, complementary gauges and sizes are available:

Reference / SKU Variant
AMP114HSP780-2 PGA Prime, 2×HSP 7, USP 8/0, violet, 30 cm (current product)
AMP111HSP770-2 PGA Prime, 2×HSP 7, USP 7/0, violet, 45 cm (same needle, slightly larger gauge)
AMP111HSP860-2 PGA Prime, 2×HSP 8, USP 6/0, violet, 45 cm (more robust gauge with 8 mm needle)
AMP121HSP860-2 PGA Prime, 2×HSP 8, USP 6/0, colourless, 45 cm (colourless version of the same format)
P1L11HSP770-2 PGLA (Polyglactin 910) Prime, 2×HSP 7, USP 7/0, 45 cm (alternative absorption material 56-72 days; not interchangeable without clinical validation)

Single-use product, sterile and not to be resterilised; check the blister integrity and expiry date before each use, keep the reference P114HSP780-2 together with the batch number for traceability in the operating theatre and store below 30 °C, away from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team of Cahnos.

Additional information

Material

Polyglycolic acid (PGA) 100 % synthetic

Construction

Braided multifilament, non-grooved surface (Prime)

Coating

Polycaprolactone and calcium stearate

Absorption

By hydrolysis; complete mass absorption in 60-90 days

Metric EP

0.4

Thread diameter

0.040 – 0.049 mm

Needle type

Spatulated Micropoint Spatula

Needle size

HSP 7 mm, double-armed 2x (2×HSP 7 Prime)

Swaged

Double needle (2x)

Sterilisation

Ethylene oxide (EO); sterile, single-use, non-resterilisable

Presentation

Box of 12 units (individual sterile sachets)

Indications

Approximation of soft and laminar tissues, ligatures, microsurgery and general precision surgery

Storage

Below 30 °C, protected from moisture and direct sunlight

Regulatory standard

Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures

Quality

Prime (Premisut Prime)

Manufacturer reference

P114HSP780-2

Units per box

12

Minimum order

10 boxes

Structure

Braided multifilament, non-grooved surface (Prime)

Medida de aguja

HSP 7

Usp

8/0

Color

Violet

Medida de hilo

30 cm

Tipo de aguja

Spatulated

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture · Double ½ Circle Spatula Micropoint Needle 7 mm (2×HSP 7) · USP 8/0 Violet · 30 cm · Box of 12 units · Ref. P114HSP780-2”

Your email address will not be published. Required fields are marked *