We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable PGA Prime Multifilament Suture · USP 6/0 · Double ½-Circle Spatulated Micropoint Needle 8 mm (2×HSP 8) · Violet 45 cm · Box of 12 units · Ref. P111HSP860-2

Original price was: 294,27 €.Current price is: 155,80 €.

Absorbable multifilament suture of 100% polyglycolic acid (PGA) in USP gauge 6/0 (metric EP 0.7), Prime quality, with double ½-circle spatulated Micropoint needle, 8 mm (format 2×HSP 8 Prime), violet non-grooved thread, 45 cm. Coated with polycaprolactone and calcium stearate, it is absorbed by hydrolysis in 60-90 days and retains 75% of tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterilised by ethylene oxide (EO), single-use and non-resterilisable, in a box of 12 individual pouches with batch traceability. Ideal for approximation of soft and laminar tissues, ligatures, microsurgery and precision general surgery. Factory ref. P111HSP860-2 · SKU AMP111HSP860-2.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP111HSP860-2

Description

1. Product Presentation

The Absorbable Multifilament PGA Prime Suture in USP 6/0 gauge is the reference that your operating theatre service, ophthalmology unit or purchasing department needs for precision procedures: it mounts a double ½ circle spatulated Micropoint needle of 8 mm (format 2×HSP 8 Prime) on a braided thread of 100% absorbable polyglycolic acid (PGA), in violet colour and 45 cm strand. Professional presentation in a box of 12 sterile units with batch traceability, ideal for supplier approval, public procurement tenders and hospital supply agreements. Factory ref. P111HSP860-2 · SKU Cahnos AMP111HSP860-2.

2. Technical explanation

The thread is made of polyglycolic acid (PGA), a synthetic linear-chain polyester that degrades by hydrolysis with predictable kinetics: mass absorption is completed between 60 and 90 days, while tensile strength is maintained during the critical healing phase (75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks). The coating of polycaprolactone and calcium stearate reduces friction and the sawing effect on tissue, improves thread sliding and facilitates knot seating with excellent knot security and minimal tissue reaction.

The spatulated Micropoint needle has a lateral flat cutting edge that separates and displaces the fibres of lamellar tissues (cornea, conjunctiva, sclera, thin skin) rather than cutting them, minimising trauma and the risk of leakage. The Prime finish (non-grooved surface) optimises passage through tissue. Its double-needle format (one at each end of the thread) allows continuous sutures to be performed without rethreading and a more balanced distribution of tension. Product sterile by ethylene oxide (EO), single-use, non-reesterilizable and conforming to USP/EP pharmacopoeias for sterile absorbable sutures.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / quality PREMISUT PRIME (premium range of multifilament suture)
Thread material Polyglycolic acid (PGA) 100 % synthetic
Structure Braided multifilament, non-grooved surface
Coating Polycaprolactone and calcium stearate
Absorption type By hydrolysis; complete mass absorption in 60-90 days
Gauge / size USP 6/0 (metric EP 0.7)
Thread diameter 0.070 – 0.099 mm (USP/EP Pharmacopoeia)
Needle shape ½ circle (1/2 circular)
Tip type Spatulated Micropoint Spatula (profile 2×HSP 8 Prime)
Needle size 8 mm
Swaged Double needle (2 needles, format 2×HSP 8)
Thread length 45 cm
Thread colour Violet (also available colourless in other presentations)
Sterilisation Ethylene oxide (EO); single-use, not re-sterilisable
Indications Approximation of soft and lamellar tissues, ligatures, ophthalmic surgery and precision general surgery
Commercial presentation Box of 12 units (individual sterile sachets)
Storage Below 30 °C, protected from moisture and direct sunlight
Regulatory standard Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures
Factory reference P111HSP860-2
SKU Cahnos AMP111HSP860-2

3.2. Tensile strength and absorption profile

Period Remaining tensile strength Absorption
2 weeks Approximately 75 % —
3 weeks Approximately 50 % —
4 weeks Approximately 40 % —
60-90 days — Complete absorption by hydrolysis

3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
8/0 0.4 0.040 – 0.049 mm
7/0 0.5 0.050 – 0.069 mm
6/0 (this product) 0.7 0.070 – 0.099 mm
5/0 1.0 0.100 – 0.149 mm
4/0 1.5 0.150 – 0.199 mm

4. Equivalences and Cross-References

The reference P111HSP860-2 corresponds to the official nomenclature of the PREMISUT PRIME range (HSP 8 profile: 8 mm spatulated Micropoint needle in ½ circle, USP 6/0 gauge, 45 cm violet thread, double-needle configuration) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering. Within the PREMISUT system itself, this same configuration is directly interchangeable with the colourless thread version (SKU AMP121HSP860-2) and, in ¼ circle curvature with identical 8 mm spatulated needle and same gauge, with reference AMP111VSP860-2.

Braided polyglycolic acid with precision spatulated needle is one of the most standardised absorbable suture families on the market. However, there is no manufacturer-validated equivalence table that cross-references this specific configuration (100% PGA, USP 6/0, double spatulated ½ circle 8 mm needle, 45 cm violet strand, Prime quality) with references from other manufacturers; consult the technical department before using in tenders. Other homologous families of braided absorbable suture with spatulated needle —Ethicon Coated VICRYL® (polyglactin 910, Sabreloc/Micropoint spatulated needle), B. Braun Safil® (PGA, VLM micropoint lancet needle), SMI Surgicryl® PGA Ophthalmic (OSU family), Dexon II (PGA, Medtronic) and the Novosyn range from B. Braun— must be reviewed property by property (material, coating, USP/metric gauge, curvature, point family, needle size and number, strand length, colour and CE/MDR regulatory classification) before any substitution. This needle geometry (HSP 8, USP 6/0, 45 cm, double needle) is only fully safely interchangeable within the PREMISUT system itself.

5. Selection tips and variants of interest

The USP 6/0 gauge (EP metric 0.7, diameter 0.070-0.099 mm) with double 8 mm spatulated needle in ½ circle is the usual choice for approximation of delicate lamellar tissues, microsurgery, anterior ophthalmic surgery and precision general surgery; the spatulated tip dissects the plane without cutting it and reduces the risk of leakage. In the same 2×HSP 8 mm format, a colourless thread version is available (SKU AMP121HSP860-2); if you prefer ¼ circle curvature with the same 8 mm needle and gauge, refer to reference AMP111VSP860-2. For finer gauges of the same ½ circle spatulated family, USP 7/0 with 7 mm needle (SKU AMP111HSP770-2) and USP 8/0 with 7 mm needle (SKU AMP111HSP780-2) are available. For a polyglactin 910 absorption profile (56-72 days) with spatulated needle geometry, the PREMISUT Polyglactin range offers reference P1L11VSP860-2: remember that the polymer composition changes and it is not interchangeable for indication purposes without clinical validation. Single-use, sterile and non-reesterilizable product; check the integrity of the blister and the expiry date before each use, keep reference P111HSP860-2 together with the batch number for traceability in the operating theatre and store below 30 °C. For B2B volume conditions, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team of Cahnos.

Additional information

Material

Polyglycolic acid (PGA) 100 % synthetic

Structure

Braided multifilament, non-grooved surface (Prime)

Coating

Polycaprolactone and calcium stearate

USP size

USP 6/0 (metric EP 0.7)

Thread diameter

0.070 – 0.099 mm (USP/EP Pharmacopoeia)

Tip type

Spatulated Micropoint Spatula (profile 2×HSP 8 Prime)

Needle size

8 mm

Swaged

Double needle (2 needles, format 2×HSP 8)

Absorption

By hydrolysis; complete absorption in 60-90 days

Sterilisation

Ethylene oxide (EO); single-use, non-reesterilizable

Presentation

Box of 12 units (individual sterile sachets)

Indications

Approximation of soft and lamellar tissues, ligatures, ophthalmic surgery and precision general surgery

Regulatory standard

Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures

Manufacturer reference

P111HSP860-2

Medida de aguja

HSP 8

Usp

6/0

Color

Violet

Medida de hilo

45 cm

Tipo de aguja

Spatulated

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable PGA Prime Multifilament Suture · USP 6/0 · Double ½-Circle Spatulated Micropoint Needle 8 mm (2×HSP 8) · Violet 45 cm · Box of 12 units · Ref. P111HSP860-2”

Your email address will not be published. Required fields are marked *