We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID · Needle 3/8 Circle Body and Triangular Point Reverse Cutting DS19 (19 mm) · USP 5/0 (Metric 1) · Colourless · 75 cm · Box of 12 units · Ref. 2L22DS1950

Original price was: 33,78 €.Current price is: 26,70 €.

Absorbable multifilament PGLAR suture (Polyglactin 910) in RAPID variant, range PREMISUT RAPID, mounted with a ⅜ circle needle, body and triangular point with reverse cutting, of 19 mm (DS19 profile), USP size 5/0 (metric 1) and colourless grooved thread of 75 cm. Accelerated and predictable absorption by hydrolysis in 40–45 days: retains 50% of initial tensile strength at 5 days and loses it completely at 14 days, being the ideal choice for fast-healing tissues. Sterilised by gamma radiation, single-use, with minimal tissue reaction and excellent knot tying; indicated for approximation of fine tissues, ligatures and ophthalmic surgery. Presentation in box of 12 units. Factory ref. 2L22DS1950 · SKU AM2L22DS1950.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM2L22DS1950

Description

1. Commercial Introduction

The Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID from the PREMISUT RAPID range is the reference for accelerated absorption surgical closure for hospitals, general surgery operating theatres, dermatology and minor surgery, emergency services, ophthalmology clinics and B2B purchasing centres that need a braided, flexible thread with a totally predictable early loss of strength.

Its ⅜ circle needle with triangular reverse-cutting body and point of 19 mm (DS19) ensures clean, controlled penetration in skin and firm tissues, while the undyed fluted 75 cm thread offers maximum discretion on the surgical field. A practical and cost-effective presentation, in a box of 12 sterile units, designed for fast-healing tissues.

2. Technical Explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure coated with a fluted finish that promotes thread slippage, smooth handling and a firm, secure knot.

In the RAPID variant (low molecular weight polyglactin 910), the thread is formulated to lose tensile strength in an accelerated and programmed manner: it retains 50% of the initial resistance at 5 days and 0% at 14 days, with complete absorption by hydrolysis between 40 and 45 days. This profile makes it especially suitable for superficial tissues with rapid healing (skin closure, mucous membranes, subcutaneous tissue), ligation of small-calibre vessels and conjunctival suture in ophthalmic surgery, where prolonged tensile support or material removal is not required.

The reverse cutting needle (reverse cutting) orientates the cutting edge away from the wound, creating a clean entry hole that preserves the skin edge and prevents the cut from widening at the puncture site. Sterile single-use product, non-resterilisable.

3. Technical Specifications

3.1. General characteristics (Ref. 2L22DS1950 · SKU AM2L22DS1950)

Parameter Specification
Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant
Thread structure Braided coated multifilament, fluted finish
Gauge USP 5/0 (metric 1)
Thread diameter 0.10 – 0.149 mm (approximate, according to Pharmacopoeia)
Thread colour Colourless
Thread length 75 cm
Needle shape 3/8 circle (135°)
Needle body and point Triangular, reverse cutting
Needle size 19 mm (DS19)
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Commercial format Box of 12 units
Factory reference 2L22DS1950

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 40 – 45 days
Tensile strength at 5 days 50% of initial strength
Tensile strength at 14 days 0% (total loss of tensile support)
Absorption rate Predictable and uniform

3.3. Size equivalence

USP size Metric size Approximate diameter
5/0 1 0.10 – 0.149 mm (approximate, according to Pharmacopoeia)

4. Equivalences and Cross-References

Fast-absorption polyglactin 910 (low molecular weight) is the most widespread category of fast-acting braided multifilament absorbable in the surgical market, whose international clinical benchmark is Ethicon’s VICRYL RAPIDE line (Johnson & Johnson MedTech). This reference shares material, accelerated absorption profile, tensile retention (≈50% at 5 days / 0% at 14 days), USP 5/0 gauge, ⅜ circle curvature, reverse cutting point, undyed thread and 75 cm length with the following code confirmed in the manufacturer’s official catalogue (Ethicon EMEA) and authorised distributors:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (braided polyglactin 910, colourless) VR2296 – USP 5/0, FS-3 needle of 16 mm in ⅜ circle, reverse cutting point, 75 cm colourless thread Comparable by category (not interchangeable 1:1) Almost complete match of attributes: same material and accelerated absorption (≈50% at 5 days), USP 5/0 gauge, ⅜ curvature, reverse cutting point, undyed 75 cm thread and box of 12/36; the needle size (FS-3 of 16 mm versus DS19 of 19 mm) and needle nomenclature differ. Code confirmed in Ethicon EMEA catalogue and authorised distributors; check the official data sheet before substituting.

There is no manufacturer-validated equivalence table that cross-references this reference with other brands; consult the technical department before using in tenders. Comparable ranges in the fast-absorption segment include Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category in terms of material and absorption profile, although for the exact combination USP 5/0 / DS19 needle / 75 cm their specific codes must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not equivalent to this RAPID version.

5. Selection tips and variants of interest

The USP 5/0 gauge (metric 1) with a ⅜ circle needle with a 19 mm triangular reverse cutting point is ideal for fine and delicate tissues: skin, mucous membranes, conjunctiva, ophthalmic surgery, paediatric surgery and superficial approximations where maximum fineness is required with short-term tensile support, without tearing the skin edge.

Within the same PGLAR Polyglactin 910 RAPID family with triangular needle, Cahnos offers complementary configurations: the same DS19 needle and USP 5/0 gauge in Prime quality (SKU AMP2L22DS1950), the DS16 variant in standard USP 5/0 (SKU AM2L22DS1650) and Prime (SKU AMP2L22DS1650), the smaller DS12 needle in Prime (SKU AMP2L22DS1250) and the cylindrical needle family with conical point HR17 in the same gauge (SKU AM2L22HR1750) for looser tissues. If the protocol prefers a conical point for less firm tissues, consider the HR family; the undyed version offers maximum discretion in the field, and if greater visibility is required, request the same configuration in dyed thread on demand.

Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure and keep it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalents from other manufacturers, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR) – copolymer 90% glycolide / 10% L-lactide, RAPID variant

Thread structure

Braided coated multifilament, fluted finish

Gauge

USP 5/0 (metric 1)

Thread diameter

0.10 – 0.149 mm (guideline according to Pharmacopoeia)

Needle shape

3/8 circle (135°)

Needle type

Triangular body and point, reverse cutting

Needle size

19 mm (DS19)

Tensile strength

50% at 5 days / 0% at 14 days

Sterilisation

Gamma radiation – single-use, non-resterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Manufacturer reference

2L22DS1950

Medida de aguja

DS 19

Usp

5/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID · Needle 3/8 Circle Body and Triangular Point Reverse Cutting DS19 (19 mm) · USP 5/0 (Metric 1) · Colourless · 75 cm · Box of 12 units · Ref. 2L22DS1950”

Your email address will not be published. Required fields are marked *