Description
1. Product Presentation
The Absorbable Multifilament PGA Prime Suture from the PREMISUT range, list reference P121HSP860-2, is the precision solution that your operating theatre service, ophthalmology unit or purchasing department needs for procedures that demand maximum mechanical performance and fully predictable absorption. It features a double ½ circle spatula Micropoint needle of 8 mm (2×HSP 8 Prime format) on a braided thread of polyglycolic acid (PGA) 100% absorbable, in undyed colour and 45 cm strand, with a non-grooved surface.
Professional presentation in a box of 12 sterile units with batch traceability, ideal for supplier approval, public procurement tenders and hospital supply agreements. Supplied with a minimum order of 10 boxes. Factory ref. P121HSP860-2 · SKU Cahnos AMP121HSP860-2.
2. Technical Explanation
The thread is made of polyglycolic acid (PGA), a linear-chain synthetic polyester that degrades by hydrolysis with predictable kinetics independent of the patient’s enzymatic activity: mass absorption is completed between 60 and 90 days, while tensile strength is maintained during the critical healing phase (≈75 % at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks). The polycaprolactone and calcium stearate coating reduces friction and the sawing effect on tissue, improves thread glide and facilitates knot seating, with excellent knot security and minimal tissue reaction.
The Micropoint spatula needle of ½ circle has a flat lateral edge that separates and displaces the fibres of lamellar tissues (cornea, conjunctiva, sclera, thin skin) rather than cutting them, minimising trauma and the risk of leakage. The Prime finish (non-grooved surface) optimises passage through tissue. Its double-needle format (one at each end of the thread) allows continuous sutures to be performed without rethreading and a more balanced distribution of tension. Product sterile by ethylene oxide (EO), single-use, non-reesterilizable and conforming to USP/EP pharmacopoeias for sterile absorbable sutures.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / quality | PREMISUT PRIME (premium range of multifilament suture) |
| Thread material | Polyglycolic acid (PGA) 100 % synthetic |
| Structure | Braided multifilament, non-grooved surface (Prime) |
| Coating | Polycaprolactone and calcium stearate |
| Absorption type | By hydrolysis; complete mass absorption in 60-90 days |
| Gauge / size | USP 6/0 (metric EP 0.7) |
| Thread diameter | 0.070 – 0.099 mm (USP/EP Pharmacopoeia) |
| Needle shape | ½ circle (1/2 circular) |
| Tip type | Spatulated Micropoint Spatula (profile 2×HSP 8 Prime) |
| Needle size | 2 × 8 mm (double needle, 2×HSP 8 format) |
| Swaged | Double needle (one at each end of the thread) |
| Thread length | 45 cm |
| Thread colour | Colourless |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Indications | Approximation of soft and laminar tissues, ligatures, microsurgery and general precision surgery |
| Commercial presentation | Box of 12 units (sterile individual pouches); minimum order 10 boxes |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures |
| Factory reference | P121HSP860-2 |
| SKU Cahnos | AMP121HSP860-2 |
3.2. Tensile strength and absorption profile
| Period | Remaining tensile strength | Absorption |
|---|---|---|
| 2 weeks | Approximately 75 % | — |
| 3 weeks | Approximately 50 % | — |
| 4 weeks | Approximately 40 % | — |
| 60-90 days | — | Complete absorption by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 7/0 | 0.5 | 0.050 – 0.069 mm |
| 6/0 (this product) | 0.7 | 0.070 – 0.099 mm |
| 5/0 | 1 | 0.100 – 0.149 mm |
| 4/0 | 1.5 | 0.150 – 0.199 mm |
4. Equivalences and Cross-References
The reference P121HSP860-2 corresponds to the official nomenclature of the PREMISUT PRIME range (HSP 8 profile: 8 mm Micropoint spatula needle in ½ circle, USP 6/0 gauge, 45 cm undyed thread, double-needle configuration) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Within the PREMISUT system itself, this same configuration is directly interchangeable with the violet thread version (SKU AMP111HSP860-2, ref. P111HSP860-2), which shares material, gauge, needle, curvature and length and differs only in the colour of the strand. This is the only exact reference equivalence that can be declared, reserved for the same manufacturer.
The following rows are offered as a verified functional comparison against official sources (manufacturer catalogue and GUDID/FDA database) and must be validated against the IFU before any substitution. As they are from another brand, they do not constitute an exact reference equivalence.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| SMI (Belgium) | Surgicryl® PGA Ophthalmic – Side Cutting Spatula double needle, 2×HSP 8 mm, ½ circle, USP 6/0, 45 cm, violet | OSU061 (SMI official ophthalmic catalogue) | Comparable by category (not interchangeable 1:1) | They match base material (PGA 100%), coating (polycaprolactone and calcium stearate at 1%), hydrolytic absorption 60-90 days, double spatula needle of 8 mm in ½ circle, USP 6/0 gauge and 45 cm length. The colour of the strand differs (violet vs undyed): SMI does not offer this configuration in undyed strand. |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® (polyglactin 910) – SABRELOC conventional spatula, S-28 / S-28 of 8 mm, ½ circle, 6-0, 45 cm, violet braided | J562G (confirmed in GUDID/FDA, Ethicon LLC, UDI-DI 10705031041257) | Comparable by category (not interchangeable 1:1) | They match USP 6/0 gauge, 45 cm length, double spatula needle configuration of 8 mm in ½ circle and braided format. They differ in material (polyglactin 910 vs PGA 100%), coating (polyglactin 370 and calcium stearate vs polycaprolactone/calcium stearate), absorption kinetics (56-72 days vs 60-90 days) and strength retention at the 4th week (≈30% vs 40%). |
B. Braun Safil® (pure PGA) publishes its spatula counterpart with micropoint lancet needle VLM 8 in ¼ circle curvature (ref. G1048734, confirmed in GUDID/FDA), but a ½ circle configuration with 8 mm spatula needle, USP 6/0 and 45 cm could not be confirmed in official sources; therefore it is not listed in this table without prior verification.
There is no manufacturer-validated equivalence table that cross-references this specific configuration (PGA 100%, USP 6/0, double spatula needle ½ circle of 8 mm, undyed strand of 45 cm, Prime quality) with references from other houses; consult the technical department of Cahnos before using in tendering.
5. Selection tips and variants of interest
The USP 6/0 gauge (metric EP 0.7, diameter 0.070-0.099 mm) with double spatula needle of 8 mm in ½ circle is the usual choice for approximation of delicate lamellar tissues, microsurgery, anterior ophthalmic surgery and precision general surgery; the spatula tip dissects the plane without cutting it and reduces the risk of leakage. The undyed thread is selected when no additional pigment is desired on the surgical field or by specialty protocol.
| Reference / SKU | Variant |
|---|---|
| AMP121HSP860-2 | PGA Prime, 2×HSP 8, USP 6/0, undyed, 45 cm (current product) |
| AMP111HSP860-2 | PGA Prime, 2×HSP 8, USP 6/0, violet, 45 cm (identical configuration in violet thread) |
| AMP111HSP770-2 | PGA Prime, 2×HSP 7, USP 7/0, violet, 45 cm (adjacent finer gauge in the same ½ circle family) |
| AMP111VSP860-2 | PGA Prime, 2×VSP 8, USP 6/0, violet, 45 cm (same fineness in ¼ circle curvature) |
| AMP111VSP850-2 | PGA Prime, 2×VSP 8, USP 5/0, violet, 45 cm (larger gauge in ¼ circle curvature) |
| AMP111DSP6,570-2 | PGA Prime, 2×DSP 6.5, USP 7/0, violet, 45 cm (same spatulated family in 3/8 curvature) |
| P1L21HSP860-2 | PGLA Prime (polyglactin 910), 2×HSP 8, USP 6/0, colourless, 45 cm (same geometry, absorption 56-72 days; different polymer composition, not interchangeable without clinical validation) |
Single-use product, sterile and non-reesterilizable; check the integrity of the blister and the expiry date before each use, keep the reference P121HSP860-2 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team of Cahnos.