Description
1. Product Presentation
The absorbable multifilament polyglycolic acid (PGA) suture in Prime quality from Cahnos, reference P118HR1730-2 (SKU AMP118HR1730-2), is the reference synthetic absorbable solution for the professional who demands predictable behaviour, excellent tensile strength and great security in knot tying. Its configuration of double needle of ½ circle, cylindrical body and Taperpoint conical point of 17 mm (2xHR17) allows continuous sutures with anchoring at both ends, optimising times and consumables in the operating theatre.
It is the ideal choice for the approximation of soft tissues, ligatures and general surgery, in a professional format of a box of 12 units, designed for stock management in operating theatres, clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers (minimum order of 30 boxes).
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided and grooved multifilament structure, which gives it great handleability, low memory, regular surface and smooth sliding through tissue. The coating of polycaprolactone and calcium stearate reduces friction and the sawing effect, facilitating precise knot placement even in fine gauges such as USP 3/0.
Absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days: during the first weeks of healing the thread maintains the necessary tensile strength (75% at 2 weeks, 50% at 3 and 40% at 4), just enough time for the tissue to recover its own strength.
The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) of 17 mm separates the fibres without cutting effect: it is the most atraumatic configuration for delicate and friable tissues, with controlled passage and minimal injury along the penetration path. The double needle format (2xHR17) facilitates continuous suture techniques and bidirectional anchoring, avoiding rethreading and reducing thread manipulation. The grooved violet colour guarantees optimal visibility over the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AMP118HR1730-2
| Parameter | Specification |
| Reference (SKU) | AMP118HR1730-2 |
| Factory reference | P118HR1730-2 |
| Quality / Brand | Prime · Cahnos |
| Suture type | Absorbable synthetic multifilament |
| Material | 100 % polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, grooved |
| USP / metric gauge | 3/0 (metric 2) |
| Thread diameter | 0.20 – 0.249 mm (USP/EP standard) |
| Thread colour | Violet grooved |
| Thread length | 70 cm per needle (2×70 cm, double needle) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical Taperpoint, atraumatic |
| Needle size | 17 mm (2xHR17, double needle) |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60–90 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60–90 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
4. Equivalences and Cross-References
Braided coated polyglycolic acid is the most well-established absorbable multifilament medium-absorption raw material in surgical practice (classic family type «Dexon»). This Prime reference, with hydrolysis absorption of 60–90 days and tensile strength retention of 75/50/40% at 2/3/4 weeks, shares polymer, coating (polycaprolactone and calcium stearate at 1%) and clinical profile with homologous PGA lines on the market. The verified correspondences against official source (GUDID/FDA and manufacturer catalogue) are detailed below:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| B. Braun | Safil® Violet (braided coated polyglycolic acid, violet) | C1048904 – SAFIL VIOLET 3/0 (2) 70CM 2XHR17 (M); DI GUDID 04038653943005 | Comparable by category (not interchangeable 1:1) | Same material (PGA), same coating, USP 3/0 gauge (metric 2), length of 70 cm and double needle configuration 2xHR17 (½ circle, cylindrical body, conical point). Confirmed in GUDID/FDA database and European device registry; verify IFU and commercial availability in the region before substituting. |
| SMI (Belgium) | Surgicryl® PGA (braided coated polyglycolic acid, violet) | 11200117 – USP 3/0 (metric 2), 1/2 circle needle, round body, conical point HR 17 mm, 75 cm, violet (official SMI catalogue, Rev. 10) | Comparable by category (not interchangeable 1:1) | Same polymer (PGA), same coating (polycaprolactone and calcium stearate at 1%), same absorption 60–90 days and same needle geometry HR 17 mm; they differ in configuration (single needle versus double needle) and thread length (75 cm versus 70 cm). |
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before using in tenders. At category level, they are also homologous lines of braided coated PGA: DemeTECH DemeSORB® PGA, Assut AssuCryl® PGA and the historical Medtronic Dexon®/Dexon II® range; Ethicon Vicryl® (polyglactin 910) shares the needle geometry and multifilament behaviour, but presents a different absorption profile (56–72 days). In all cases, any substitution must be validated code by code verifying material, gauge, needle geometry (shape, body, point and size), configuration (single or double needle), thread length and presentation in the technical data sheet or IFU of each manufacturer.
5. Selection tips and variants of interest
The USP 3/0 gauge (metric 2) combines excellent initial tensile strength with a fine-medium diameter, indicated for the approximation of tissues with moderate tension, ligatures and general surgery. The double needle presentation 2xHR17 is especially practical for continuous sutures with anchoring at both ends, avoiding rethreading.
- AM118HR1730-2: same double needle configuration HR17, USP 3/0, violet, 2×70 cm in standard quality (factory reference 118HR1730-2), for cost optimisation.
- P1L18HR1730-2 / 1L18HR1730-2: same double needle format HR17 and gauge in polyglactin 910 (PGLA), with absorption of 56–72 days, to compare materials and unify stocks.
- AMP118HR1330 / AMP118HR1340: same PGA Prime family with single needle HR13 in USP 3/0 and 4/0 gauges, violet, 70 cm.
- AMP118HR1760: HR17 needle in USP 6/0 gauge, for finer planes.
- AMP118HR1050: HR10 needle in USP 5/0 gauge, for low-tension tissues.
- AMP112HR1730: HR17 needle, 3/0 gauge, with 75 cm thread.
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to the healthcare centre. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalents from other commercial brands, contact our technical-commercial team.





Reviews