We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime — Needle 1/2 Circle Cylindrical Conical Point HR26 mm, USP 4/0, Undyed Thread 70 cm (Box of 12 units)

Original price was: 43,23 €.Current price is: 34,80 €.

Absorbable multifilament suture PGLAR Polyglactin 910 RAPID Prime, with ½ circle needle of cylindrical body and conical point (taperpoint) of 26 mm (HR26). USP 4/0 gauge, undyed grooved thread of 70 cm. Predictable absorption by hydrolysis in 40–45 days: retains 50% of tensile strength at 5 days and loses all its strength at 14 days, ideal for fast-healing tissues. Sterile by gamma radiation. Indicated for soft tissue approximation, ligatures and ophthalmic surgery. Manufacturer reference P2L28HR2640 (SKU AMP2L28HR2640). Price per box of 12 units, made to order.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L28HR2640

Description

1. Introduction

The Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime is the reference choice for the professional who needs a synthetic absorbable thread with predictable behaviour, excellent handling and rapid loss of strength, designed for fast-healing tissues. Its presentation with an attached needle reduces handling in the operating theatre, optimises surgical times and guarantees batch traceability. Available in a box of 12 units.

2. Technical explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, structured as a grooved multifilament braid that provides flexibility, smoothness when sliding and great security in knot tying. Its absorption occurs by hydrolysis, without depending on tissue enzymes, which guarantees uniform kinetics between patients. The RAPID variant is optimised for short-term support: it retains 50% of tensile strength at 5 days and loses 100% at 14 days, being completely eliminated between 40 and 45 days. The ½ circle needle with cylindrical body and taperpoint conical point (HR26) passes through soft tissues with minimal injury, ideal for tissue approximation, ligatures and ophthalmic surgery.

3. Technical Specifications

Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament, grooved, colourless
Gauge USP 4/0
Thread length 70 cm
Needle ½ circle, cylindrical body, taperpoint conical point, 26 mm (HR26), Prime quality
Absorption By hydrolysis, between 40 and 45 days
Tensile strength 50% at 5 days; 0% at 14 days
Colour Colourless (undyed)
Sterilisation Gamma radiation
Presentation Box of 12 units
Manufacturer reference P2L28HR2640 (SKU AMP2L28HR2640)

4. Equivalences and Cross-References

At category level, polyglactin 910 RAPID corresponds to the market’s synthetic absorbable braided sutures with rapid absorption. The closest family is VICRYL RAPIDE™ (low molecular weight polyglactin 910, same composition and same absorption profile). The following cross-references have been checked against authorised distributor sources; before substituting in a tender, always check against the manufacturer’s IFU.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Ethicon / J&J MedTech VICRYL RAPIDE™ (polyglactin 910) V2180H Comparable by category (not interchangeable 1:1) It matches in USP 4/0 gauge, undyed thread of 70 cm, ½ circle needle of 26 mm with conical point (SH-1). Same material and absorption profile; differs in coating and needle mounting compared to this reference. Check IFU before substituting.
Ethicon / J&J MedTech VICRYL RAPIDE™ (polyglactin 910) V2140H Comparable by category (not interchangeable 1:1) It matches in USP 4/0 gauge, undyed thread of 70 cm and taperpoint conical point, but the needle is RB-1 Plus of 17 mm, not 26 mm (HR26). Not interchangeable 1:1; verify required needle geometry.

There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender. Any other brand of rapid-absorption polyglactin 910 should be checked against its technical data sheet and IFU before proposing substitution.

5. Selection tips and variants of interest

To choose the correct suture, verify three parameters: USP gauge (this model, USP 4/0, is intended for delicate soft tissues and superficial approximations), needle geometry (½ circle with taperpoint conical point of 26 mm for minimal trauma; the reverse cutting variant is reserved for denser tissues) and thread length (70 cm). In the PGLAR Polyglactin 910 RAPID Prime family, other configurations are available with HR26 needle in USP 0, USP 2/0 and USP 3/0 gauges, as well as double thread presentations of 2×75 cm for greater performance per unit. If the priority is cost per stitch without changing the configuration, consider the standard quality version of the same family.

Additional information

Material

Polyglactin 910 (90 % glycolide / 10 % L-lactide)

Thread structure

Multifilament braided fluted

Needle

1/2 circle, cylindrical body, taperpoint conical point, 26 mm (HR26), Prime quality

Tensile strength

50 % at 5 days; 0 % at 14 days

Sterilisation

Gamma radiation

Presentation

Box of 12 units

Manufacturer reference

P2L28HR2640

Medida de aguja

HR 26

Usp

4/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime — Needle 1/2 Circle Cylindrical Conical Point HR26 mm, USP 4/0, Undyed Thread 70 cm (Box of 12 units)”