Description
1. Product Presentation
The absorbable multifilament suture of polyglycolic acid (PGA) from the Premisut range, factory reference 118HR1730-2 (SKU AM118HR1730-2), is the reference synthetic absorbable solution for the professional who demands predictable behaviour, excellent tensile strength and great security in knot tying. This presentation incorporates a atraumatic double needle of ½ circle with cylindrical body and Taperpoint conical point of 17 mm (2xHR17), USP 3/0 gauge (metric 2) and violet grooved braided thread of 70 cm per needle (2×70 cm).
It is the ideal choice for the approximation of soft tissues, ligatures and general surgery, in a professional format of a box of 12 units, designed for stock management in operating theatres, clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers (minimum order of 30 boxes). Price per box.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure and coated with polycaprolactone and calcium stearate. This configuration gives the thread a regular (grooved) surface that favours sliding through tissue, smooth handling, low memory and firm, secure knot tying, even in fine gauges such as USP 3/0.
Its absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days: during the first weeks of healing the thread retains the necessary tensile strength (75% at 2 weeks, 50% at 3 and 40% at 4), just enough time for the tissue to recover its own resistance.
The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) of 17 mm separates the fibres without cutting effect: it is the most atraumatic configuration for delicate and friable tissues, with controlled passage and minimal injury along the penetration path. The double needle 2xHR17 format facilitates continuous suture and anchoring techniques at both ends, avoiding rethreading and reducing thread manipulation in the surgical field. The grooved violet colour guarantees optimal visibility over the field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AM118HR1730-2
| Parameter | Specification |
|---|---|
| Reference (SKU) | AM118HR1730-2 |
| Factory reference | 118HR1730-2 |
| Brand / Range | Premisut – Standard quality |
| Suture type | Synthetic absorbable braided multifilament |
| Material | 100 % absorbable polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, grooved surface |
| USP / metric gauge | 3/0 (metric 2) |
| Thread diameter | 0.20 – 0.249 mm (USP/EP standard) |
| Thread colour | Braided violet (also available undyed) |
| Thread length | 70 cm (2×70 cm in double needle) |
| Swaged | Double needle (2xHR17) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 17 mm (2xHR17) |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
3.3. Size equivalence
| USP size | Approximate diameter (USP/EP standard) | Metric size |
|---|---|---|
| 3/0 | 0.20 – 0.249 mm | 2 |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
4. Equivalences and Cross-References
Coated braided polyglycolic acid is the most well-established absorbable multifilament raw material of medium absorption in surgical practice (classic family type ‘Dexon’). This Premisut reference, with hydrolysis absorption of 60–90 days, tensile strength retention of 75/50/40% at 2/3/4 weeks and a 17 mm Taperpoint cylindrical double needle, is comparable at category level (not interchangeable 1:1) with homologous PGA lines verified against official sources (GUDID/FDA database and manufacturer catalogue):
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| B. Braun | Safil® Violet (braided coated polyglycolic acid, violet) | C1048904 – SAFIL VIOLET 3/0 (2) 70 CM 2XHR17 (M); verified in GUDID, DI 04038653943005 | Comparable by category (not interchangeable 1:1) | Same 100% PGA, same USP 3/0 gauge (metric 2), same thread length (70 cm), same violet colour and same double needle configuration 2xHR17 (½ circle, cylindrical body, conical point), confirmed in GUDID/FDA; the coating differs (glyconate/calcium stearate in Safil versus polycaprolactone/calcium stearate in this reference) and the tensile strength retention profile specific to each manufacturer. Verify IFU and commercial availability in the region before substituting. |
| SMI (Belgium) | Surgicryl® PGA (braided coated polyglycolic acid, violet) | 11200117 – USP 3/0 (metric 2), ½ circle needle round body conical point HR 17 mm, 75 cm, violet (official SMI catalogue) | Comparable by category (not interchangeable 1:1) | Same polymer (PGA), same coating (polycaprolactone and calcium stearate at 1%), same absorption 60–90 days and same needle geometry HR 17 mm (½ circle, conical point); the configuration differs (single needle versus double needle 2xHR17) and the thread length (75 cm versus 2×70 cm). |
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. At category level, homologous lines of coated braided PGA also include: DemeTECH DemeSORB® PGA, Assut Sutures AssuCryl® PGA and the historical Medtronic Dexon® / Dexon II® range; however, no specific code for double needle configuration 2xHR17 + USP 3/0 + 70 cm thread has been confirmed in public sources for these manufacturers, so they cannot be tabulated as a closed reference. The polyglactin 910 lines (Ethicon Vicryl®, Medtronic Polysorb®, Safil® Quick in its PGLA variant) share the needle geometry and multifilament behaviour, but use a different copolymer (glycolide/L-lactide) with absorption of 56–72 days: they are comparable by category, not interchangeable 1:1 material to material. Any substitution must be validated code by code, verifying material, gauge, needle geometry (shape, body, point and size), configuration (single or double needle), thread length and presentation in the technical data sheet or IFU of each manufacturer.
5. Selection tips and variants of interest
The USP 3/0 gauge (metric 2) combines excellent initial tensile strength with a fine-to-medium diameter, indicated for the approximation of tissues with moderate tension, ligatures and general surgery, where reliable support is required during the first weeks of healing. The double needle 2xHR17 presentation is especially practical for continuous sutures with anchoring at both ends, avoiding rethreading and reducing operating theatre times.
Variants and alternatives from the same Cahnos catalogue:
- AMP118HR1730-2: same double-needle configuration 2xHR17, USP 3/0, violet, 2×70 cm in Prime quality, for high-demand protocols.
- 1L18HR1730-2 / P1L18HR1730-2: same HR17 double-needle format and gauge in polyglactin 910 (PGLA), with absorption of 56–72 days, to compare materials and unify stocks.
- AM118HR1330 / AM118HR1340: same PGA Premisut family with single HR13 needle in USP 3/0 and 4/0 gauges, violet, 70 cm, if bidirectional anchoring is not required.
- AM118HR1320: same PGA family with HR13 needle in USP 2/0 gauge, violet, 70 cm, for a larger thread diameter.
- AM118HR1760: HR17 needle in USP 6/0 gauge, for finer planes and low-tension tissues.
- AM112HR1730: HR17 needle in USP 3/0 gauge with 75 cm thread, for a longer strand length.
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to the healthcare facility. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, institutional rates or equivalents from other manufacturers, contact our technical-commercial team.





Reviews