Description
1. Product Presentation
The Absorbable Multifilament PGA Prime Suture in USP 6/0 gauge is the reference your operating theatre, ophthalmology unit or purchasing department needs for precision procedures: it features a double ¼ circle spatulated Micropoint needle of 8 mm on a braided polyglycolic acid (PGA) thread, 100 % absorbable, in violet colour and 45 cm strand. Professional presentation in a box of 12 sterile units with batch traceability, ideal for supplier qualification, public procurement tenders and hospital supply agreements. Factory ref. P111VSP860-2 · SKU Cahnos AMP111VSP860-2.
2. Technical Explanation
The thread is made of polyglycolic acid (PGA), a linear-chain synthetic polyester that degrades by hydrolysis with predictable kinetics: mass absorption is complete between 60 and 90 days, while tensile strength is maintained during the critical healing phase (75 % at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks). The coating of polycaprolactone and calcium stearate reduces friction and the sawing effect on tissue, improves thread glide and facilitates knot seating with excellent knot security.
The spatulated Micropoint needle features a flat lateral edge that separates and displaces the fibres of lamellar tissues (cornea, conjunctiva, sclera, fine skin) rather than cutting them, minimising trauma and the risk of leakage. The Prime finish (non-grooved surface) optimises passage through tissue. Its double-needle format allows continuous sutures to be run without rethreading and a more balanced distribution of tension. Product sterile by ethylene oxide (EO), single-use, not re-sterilisable and conforming to USP/EP pharmacopoeias for sterile absorbable sutures.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / quality | PREMISUT PRIME (premium range) |
| Thread material | Polyglycolic acid (PGA) 100 % synthetic |
| Structure | Braided multifilament, non-grooved surface |
| Coating | Polycaprolactone and calcium stearate |
| Absorption type | By hydrolysis; complete mass absorption in 60-90 days |
| Gauge / size | USP 6/0 (metric EP 0.7) |
| Needle shape | ¼ circle (1/4 circular) |
| Tip type | Spatulated Micropoint Spatula (VSP 8 Prime profile) |
| Needle size | 8 mm |
| Swaged | Double needle (2 needles, 2×VSP 8 format) |
| Thread length | 45 cm |
| Thread colour | Violet |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Indications | Approximation of soft and lamellar tissues, ligatures, ophthalmic surgery and precision general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures |
| Factory reference | P111VSP860-2 |
| SKU Cahnos | AMP111VSP860-2 |
3.2. Tensile strength and absorption profile
| Period | Remaining tensile strength | Absorption |
|---|---|---|
| 2 weeks | Approximately 75 % | — |
| 3 weeks | Approximately 50 % | — |
| 4 weeks | Approximately 40 % | — |
| 60-90 days | — | Complete absorption by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 6/0 (this product) | 0.7 | 0.070 – 0.099 mm |
| 5/0 | 1.0 | 0.100 – 0.149 mm |
| 4/0 | 1.5 | 0.150 – 0.199 mm |
| 3/0 | 2.0 | 0.200 – 0.249 mm |
4. Equivalences and Cross-References
Reference P111VSP860-2 corresponds to the official nomenclature of the PREMISUT PRIME range (VSP 8 profile: 8 mm spatulated Micropoint needle in ¼ circle, USP 6/0 gauge, 45 cm violet thread, double-needle configuration) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Braided polyglycolic acid with precision spatulated needle is one of the most standardised absorbable suture families on the market. The following rows are offered as a verified functional comparison against the GUDID/FDA database and the manufacturer’s official catalogue, and must be validated against the IFU before any substitution. As they are another brand, they do not constitute exact reference equivalence (reserved for the same manufacturer).
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | SAFIL® Violet – braided and coated PGA, 6/0 (0.7), 45 cm, double VLM 8 needle of 8 mm, ¼ circle micropoint lancet type | G1048734 (UDI-DI 04038653947348, confirmed in GUDID/FDA – B. Braun Surgical SA) | Comparable by category (not interchangeable 1:1) | They match on base material (polyglycolic acid PGA), USP 6/0 gauge (metric 0.7), 45 cm length, double 8 mm needle configuration in ¼ circle and violet colour. B. Braun does not use the term ‘spatula’: its functional equivalent is the VLM 8 micropoint lancet needle. They differ in coating (glyconate vs. polycaprolactone/calcium stearate), needle nomenclature and the exact force retention profile. |
| Ethicon (Johnson & Johnson MedTech) | COATED VICRYL® (polyglactin 910) – S-14 / S-14, 8 mm SABRELOC spatulated needle, ¼ circle, 6-0, 45 cm, braided violet | J570G (confirmed in Ethicon EMEA catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match on USP 6/0 gauge, 45 cm length, double 8 mm needle configuration in ¼ circle and violet colour. They differ in material (polyglactin 910 / PGLA vs. 100 % PGA), coating (polyglactin 370 and calcium stearate vs. polycaprolactone/calcium stearate), absorption kinetics (56-72 days vs. 60-90 days) and retention profile at the 4th week (≈30 % vs. 40 %). |
There is no manufacturer-validated equivalence table that cross-references this specific configuration (100 % PGA, USP 6/0, double ¼ circle spatulated needle of 8 mm, 45 cm violet strand, Prime quality) with references from other houses; consult the technical department before use in tendering. Other homologous families of braided absorbable suture with spatulated needle —SMI Surgicryl® PGA Ophthalmic (OSU family, available in 5/0 and 6/0 with the same 2×VSP 8 mm ¼ circle configuration), the Novosyn range from B. Braun or Dexon II (PGA, Medtronic/Covidien)— must be reviewed property by property (material, coating, USP/metric gauge, curvature, point family, needle size and number, strand length, colour and CE/MDR regulatory classification) before any substitution. This needle geometry (VSP 8, USP 6/0, 45 cm, double needle) is only fully safely interchangeable within the PREMISUT system itself.
5. Selection tips and variants of interest
The USP 6/0 (metric EP 0.7) gauge with an 8 mm spatulated needle in ¼ circle is the usual choice in anterior ophthalmic surgery (cornea, conjunctiva, eyelids), microsurgery and approximation of delicate lamellar tissues where minimal trauma is required; the spatulated tip dissects the plane without cutting it and reduces the risk of leakage. In the same 2×VSP 8 mm format, it is available in USP 5/0 (SKU AMP111VSP850-2) and USP 4/0 (SKU AMP111VSP840-2); if a shorter needle is preferred, the 6/0 version with a 6.5 mm needle (SKU AMP111VSP6,560-2). For ½ circle curvature in the same gauge and colour, reference AMP111HSP860-2; for a polyglactin 910 absorption profile (56-72 days), the PREMISUT Polyglactin range offers the same geometry in 6/0 (SKU P1L11VSP860-2): note that the polymer composition changes and it is not interchangeable for indication purposes without clinical validation. Single-use product, sterile and non-resterilisable; check the integrity of the blister and the expiry date before each use, keep reference P111VSP860-2 together with the batch number for traceability in the operating theatre and store below 30 °C. For B2B volume conditions, hospital supply agreements or validation of equivalents, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.