Description
1. Commercial Introduction
The PGLAR absorbable multifilament suture of Polyglactin 910 RAPID in PRIME quality (PREMISUT RAPID range) is the high-performance surgical reference for hospitals, ophthalmic clinics, purchasing centres and B2B surgical services that need a braided, flexible thread with early, predictable and fully documented loss of strength. It is presented in double format of 2 threads of 90 cm mounted with a ½ circle needle with cylindrical body and conical point (taperpoint) of 40 mm (HR 40), USP gauge 1 and undyed grooved thread, in a box of 12 units. A sterile, single-use product, designed for fast-healing tissues that require short-term support.
2. Technical explanation
This suture is manufactured from polyglactin 910 in its low-molecular-weight variant (RAPID), a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide that accelerates the loss of strength and mass compared with conventional polyglactin 910. Its braided multifilament structure with grooved finish and coating provides very smooth handling, controlled sliding and firm, secure knot tying.
Absorption occurs by hydrolysis over a predictable period of 40 to 45 days, with minimal tissue reaction and a tensile strength retention profile of 50% at 5 days and 0% at 14 days. The ½ circle needle with conical taperpoint tip penetrates soft tissues by separating the fibres without tearing them, making it especially suitable for skin and mucosal approximation, ligatures, episiotomies, paediatric surgery and ophthalmic surgery. The product is supplied sterile by gamma radiation and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
| Material | Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight variant (RAPID) |
| Thread structure | Braided coated multifilament, fluted finish |
| Quality | PRIME (PREMISUT RAPID range) |
| Gauge | USP 1 (metric 4) |
| Thread colour | Colourless |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | HR 40 mm |
| Thread length | 2 × 90 cm (double format) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units (minimum B2B order: 30 boxes) |
| Factory reference | P2L23HR4001.2 |
| SKU Cahnos | AMP2L23HR4001.2 |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % |
| 14 days | 0 % |
Complete absorption by hydrolysis between 40 and 45 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
4. Equivalences and Cross-References
Rapid-absorbing polyglactin 910 (low molecular weight) is one of the most widely used synthetic multifilament absorbable materials on the market. The reference analysed is comparable at category level with braided polyglactin 910 RAPID sutures from other manufacturers, both in composition and in absorption profile (≈42 days) and tension retention (≈50% at 5 days). Only the reference whose code and attributes have been verified in industry sources (manufacturer catalogue and authorised distributors) is included:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided polyglactin 910, colourless) | W9964 | Comparable by category (not interchangeable 1:1) | Same material and rapid absorption (≈42 days), USP gauge 1, undyed braided thread of 90 cm and ½ circle needle; the needle geometry differs: tapercut point of 36 mm versus the conical taperpoint HR 40 mm point of this reference. Confirm the manufacturer’s official datasheet before substituting. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As homologous reference ranges in the sector, the rapid-absorbing braided polyglactin 910 sutures from B. Braun (Safil Quick type line) are listed, as well as the absorbable braided lines from DemeTECH (DemeCRYL Fast) and SMI (Surgicryl Fast Absorb), whose specific codes for the exact combination USP 1 / conical needle HR 40 mm / 2×90 cm thread must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.
5. Selection tips and variants of interest
USP gauge 1 (metric 4) with a 40 mm conical needle is a common choice for skin and mucosal approximation, ligatures and ophthalmic surgery, with early loss of strength that avoids suture removal in many indications. Within the same PGLAR RAPID PRIME range with cylindrical needle with conical point, Cahnos offers complementary configurations:
- AMP2L23HR4001.2: this reference, double format 2 × 90 cm (higher yield per package for high-consumption services).
- AMP2L23HR4801 / AMP2L23HR4801.2: same PRIME quality and USP gauge 1, with HR 48 mm needle and undyed 90 cm thread (larger radius needle for wider fields).
- AMP2L23HR4802: PRIME HR 48 mm in USP gauge 2, undyed 90 cm thread (larger gauge for planes with more tension).
- AM2L23HR4801 / AM2L23HR4802: standard quality of the same family (economical alternative with the same geometry).
- AM2L23HRT3620 / AM2L23HRT2610: variants with trocar point (Tapercut) for somewhat firmer tissues.
- PGLA family (conventional polyglactin 910): absorption 56–72 days and longer strength retention when healing requires support for more than 2 weeks. PDO family (polydioxanone): for prolonged retention (180–210 days) in tissues under sustained tension.
All references are supplied in boxes of 12 units with a minimum order of 30 boxes for the B2B channel. As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team.