Description
1. Introduction
The absorbable multifilament suture PGLAR of Polyglactin 910 RAPID (PREMISUT RAPID, PRIME quality) is a high-quality surgical reference designed for professionals who need a braided, flexible thread with early and predictable loss of strength in the operating theatre. It is presented with a ½ circle needle with cylindrical body and conical point of 48 mm (HR 48), USP 0 gauge and colourless grooved thread in double format of 2 × 90 cm, which optimises performance per package in high-volume surgical services. The box contains 12 units, aimed at hospitals, ophthalmic clinics and B2B purchasing centres.
2. Technical explanation
This suture is made of polyglactin 910, a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide presented in its low molecular weight variant (RAPID), which accelerates the loss of strength and mass compared to conventional polyglactin 910. Its braided multifilament structure with grooved finish and coating provides very smooth handling, firm knot tying and controlled sliding.
Absorption occurs by hydrolysis over a period of 40 to 45 days, with minimal tissue reaction. The tensile strength retention profile is 50% at 5 days and 0% at 14 days, making it indicated for tissues that only require short-term support: skin and mucosa approximation, ligatures, episiotomies, paediatric surgery and ophthalmic surgery. The ½ circle needle with cylindrical body and conical point (taperpoint type) penetrates soft tissues without tearing. The product is supplied sterile by gamma radiation, single-use and cannot be resterilised.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (low molecular weight glycolide/lactide copolyester – RAPID) |
| Thread structure | Braided coated multifilament, fluted finish |
| Gauge | USP 0 |
| Thread colour | Colourless |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | HR 48 mm |
| Thread length | 2 threads × 90 cm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Factory reference | P2L23HR4810.2 |
| SKU Cahnos | AMP2L23HR4810.2 |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
|---|---|
| 5 days | 50 % |
| 14 days | 0 % |
Complete absorption by hydrolysis between 40 and 45 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
4. Equivalences and Cross-References
Polyglactin 910 RAPID (low molecular weight) is one of the most widely used synthetic absorbable materials with rapid absorption on the market. The analysed reference is comparable at category level with the braided polyglactin 910 rapid-absorption sutures from other manufacturers, both in composition and in absorption profile (≈42 days) and tension retention (≈50% at 5 days).
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson) | VICRYL RAPIDE (polyglactin 910) | VR2287 | Comparable by category (not interchangeable 1:1) | Same material, rapid absorption profile and USP 0 gauge (90 cm), but different needle (FSL) compared to HR 48 mm; verify needle geometry before substituting. |
| Ethicon (Johnson & Johnson) | VICRYL RAPIDE (polyglactin 910) | VR2294 | Not verified | Reference cited in distributors as Vicryl Rapide; confirm gauge, length and needle with the manufacturer’s official datasheet. |
| B. Braun | Absorbable braided polyglactin 910 range | — | Not verified | No specific code confirmed in official catalogue; confirm reference with the manufacturer before use in tendering. |
There is no equivalence table validated by the manufacturer; consult the technical department before using in tendering.
5. Selection tips and variants of interest
To choose the most suitable suture, assess the wound support time required by the tissue and the necessary gauge according to the anatomical area. USP 0 gauge with HR 48 mm needle is a common choice for skin and mucosa approximation, ligatures and ophthalmic surgery, with early strength loss that avoids suture removal in many indications:
- AMP2L23HR4810: same PGLAR RAPID PRIME USP 0 reference, with 1 thread of 90 cm (individual format, same quality).
- AMP2L23HR4801 / AMP2L23HR4802: PGLAR RAPID PRIME HR 48 in USP 1 and USP 2 gauges, colourless thread of 90 cm.
- AMP2L23HR4801.2 / AMP2L23HR4802.2: double format 2 × 90 cm in USP 1 and USP 2 gauges.
- AM2L23HR4810: PGLAR RAPID USP 0 HR 48 in standard quality (economical alternative).
- 1L23HR4802 and PGLA family: conventional polyglactin 910 (absorption 56-72 days and longer strength retention) when healing requires support for more than 2 weeks.
- PDO family (polydioxanone): for prolonged strength retention (180-210 days) in tissues under sustained tension.
All references are supplied in boxes of 12 units. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews