Description
1. Introduction
The Absorbable Multifilament Polyglactin 910 Rapid Suture (PGLAR Prime) is a synthetic rapidly absorbing suture designed for procedures requiring short-term tissue support with predictable healing. Its copolymeric composition of 90% glycolide and 10% L-lactide, its undyed presentation and its high-penetration needle make it a reliable option for operating theatres, minor ambulatory surgery and ophthalmology.
2. Technical explanation
Polyglactin 910 is absorbed by hydrolysis, a process that does not depend on tissue enzymes and is highly reproducible between patients. In its Rapid variant, the loss of strength is deliberately rapid: it retains 50% of its tensile strength at 5 days and loses it completely at 14 days, with complete absorption between 40 and 45 days. The braided and grooved multifilament thread offers excellent handling and knot security, while the ½ circle needle with triangular reverse cutting point precisely penetrates firm, inelastic tissues without tearing, being especially useful in skin, mucosa and ocular structures.
3. Technical Specifications
| Composition | Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide) |
| Thread type | Multifilament braided fluted |
| Gauge | USP 4/0 |
| Thread length | 75 cm |
| Colour | Colourless |
| Needle shape | ½ circle |
| Needle tip | Triangular reverse cutting (reverse cutting) |
| Needle size | 17 mm |
| Absorption mechanism | Complete hydrolysis in 40-45 days |
| Tensile strength | 50% at 5 days / 0% at 14 days |
| Sterilisation | Gamma radiation |
| Presentation | Box of 12 units (minimum order: 30 boxes) |
4. Equivalences and Cross-References
Polyglactin 910 in its rapid absorption variant has direct counterparts on the market (Ethicon VICRYL RAPIDE™, B. Braun Novosyn Quick / Safil Quick). Below are verified references from catalogues and authorised distributors; none should be considered interchangeable 1:1 without technical validation from the purchasing department.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE™ (polyglactin 910) | VR496 | Comparable by category (not interchangeable 1:1) | PS-2 reverse cutting needle of 19 mm versus 17 mm; thread of 45 cm versus 75 cm; braided undyed. |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE™ (polyglactin 910) | W9970 | Comparable by category (not interchangeable 1:1) | RB-1 ½ circle 17 mm needle with conical point (taper) versus reverse cutting; 4/0 undyed thread of 75 cm and box of 12. |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE™ (polyglactin 910) | VR214 | Comparable by category (not interchangeable 1:1) | RB-1 ½ circle 17 mm conical point (taper); 4/0 braided undyed; different point geometry. |
There is no equivalence table validated by the manufacturer that cross-references this product with other brands; consult the technical department before use in tenders. The reference homologous family in the sector is Ethicon VICRYL RAPIDE™ (polyglactin 910) and the B. Braun Novosyn Quick / Safil Quick lines, whose technical data sheets must be verified field by field (needle, gauge, length, colour) before any substitution.
5. Selection tips and variants of interest
- For firm tissues or skin: keep the triangular reverse cutting point; for soft tissues and parenchymatous organs consider the variant with a conical point from the same family.
- If you need greater length or gauge: in the same PGLAR Rapid range, cylindrical presentations (HR17, HR22, HR26) and ⅜ circle (DS12, DS16, DS19) in gauges 2/0 to 6/0.
- In ophthalmic microsurgery, a fine gauge (6/0 or 5/0) with a 12-16 mm needle is recommended; this 4/0 of 17 mm is ideal for skin and mucosa approximation with short-term support.
- Always check the expiry date and the integrity of the blister before use: it is a sterile single-use product.





Reviews