Description
1. About the suture
The absorbable suture PREMISUT Prime of Polyglactin 910 (PGLA) is the reference choice for operating theatre services, ophthalmology clinics, purchasing groups and distributors seeking a synthetic multifilament thread with controlled absorption, excellent handling and a fully predictable clinical behaviour. Its Prime quality guarantees a regular surface and smooth sliding that minimises tissue damage during suturing.
This presentation incorporates a ⅜ circle needle with triangular reverse cutting point of 30 mm (DS30), USP 2/0 gauge and 75 cm violet fluted thread, ideal for tissue approximation, ligatures and ophthalmic surgery procedures. Sterile, ready-to-use product, in a box of 12 units. Ref. P1L12DS3020.
2. Technical explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, configured in a braided multifilament structure coated with a fluted finish. This architecture favours smooth passage of the thread through tissue, offers excellent handling and guarantees high knot security, even in working gauges such as USP 2/0.
Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid and lactic acid, substances that the body metabolises without causing relevant tissue reaction. The ⅜ circle needle with reverse cutting triangular point (inverted triangle) passes through firm, non-compliant tissues with controlled trauma and no tearing, making it especially suitable for ophthalmic surgery, ligatures and tissue approximation. The violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Range | PREMISUT (Prime quality) |
| Material | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided and coated multifilament (grooved) |
| Quality | Prime |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Violet (also available colourless in the range) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting (inverted triangular) |
| Needle size | DS 30 mm (Prime) |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L12DS3020 |
3.2. Tensile strength retention profile
| Period | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56 – 72 days by hydrolysis |
Minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 2/0 | 3 | 0.30 – 0.349 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Polyglactin 910 is the most widely used medium-duration absorbable multifilament in the surgical market. This PGLA Prime suture is equivalent in chemical composition, absorption profile (56-72 days) and tensile strength retention to the main international commercial ranges:
| Manufacturer / commercial house | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided coated polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration (DS 30 mm needle, USP 2/0, violet, 75 cm) with standard quality is reference 1L12DS3020; the colourless thread version corresponds to P1L22DS3020, and the double strand 2×75 cm presentation in violet to P1L12RDS3020.2. If a longer absorption profile (60-90 days) is preferred, in the polyglycolic acid (PGA) family the reference AMP112DS3010 stands out. The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
USP 2/0 gauge (metric 3) offers an excellent balance between initial strength and handling for soft tissues under medium tension: skin, subcutaneous tissue, mucosa, fascia and ligatures. The ⅜ circle needle with 30 mm reverse cutting triangular point is especially recommended in firm, non-compliant tissues where a clean, controlled needle passage is required, including microsurgery and ophthalmic surgery. The violet thread provides maximum visibility on the surgical field; if you prefer maximum aesthetic discretion, request the colourless version (P1L22DS3020).
| Reference | Variant |
| P1L12DS3020 | PGLA Prime, DS30, USP 2/0, violet, 75 cm (current product) |
| 1L12DS3020 | PGLA standard quality, same configuration DS30, USP 2/0, violet, 75 cm |
| P1L12DS3030 | PGLA Prime, DS30, USP 3/0, violet, 75 cm (finer gauge) |
| P1L12DS3010 | PGLA Prime, DS30, USP 0, violet, 75 cm (thicker gauge) |
| P1L12RDS3020.2 | PGLA Prime, DS30, USP 2/0, violet, double strand 2×75 cm |
| P1L12DS3620 | PGLA Prime, DS36, USP 2/0, violet, 75 cm (longer needle) |
| AMP112DS3010 | Alternative in polyglycolic acid (PGA), absorption 60-90 days |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight.





Reviews