Description
Absorbable suture PREMISUT Prime Polyglactin 910 (PGLA)
The multifilament absorbable suture PREMISUT Prime Polyglactin 910 (PGLA), reference P1L11DS1260, is the professional reference solution for B2B supply to operating theatres, ophthalmic clinics, purchasing groups and healthcare distributors. It combines a synthetic copolymer with predictable clinical behaviour, exceptional handling and excellent knot security in tissue approximation, ligation and ophthalmic surgery.
Its ⅜ circle needle with a 12 mm (DS12) reverse cutting triangular point ensures firm, controlled penetration even in non-compliant tissues, while the 45 cm violet non-ribbed thread offers optimal visibility over the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile, single-use and non-resterilisable, with an excellent quality-to-performance ratio for the continuous supply of your facility.
Technical product explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a non-ribbed finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 6/0 (metric 0.7).
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance.
The ⅜ circle needle with reverse cutting triangular point penetrates firm and fibrous tissues with controlled trauma, avoiding tears; it is therefore particularly indicated in ophthalmic surgery (sclera), skin and mucous membranes. The violet colour facilitates tracking of the thread throughout the procedure. The product is supplied sterile by ethylene oxide (EtO) and must not be resterilised.
Technical specifications
Technical data sheet for reference P1L11DS1260
| Parameter | Specification |
|---|---|
| Brand / Range | PREMISUT (Prime quality, premium range) |
| Reference (SKU) | P1L11DS1260 |
| Material | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided multifilament, non-ribbed |
| Gauge | USP 6/0 (metric 0.7) |
| Thread colour | Violet |
| Thread length | 45 cm |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting (inverted triangular) |
| Needle size | DS12 (12 mm) Prime |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (EtO), single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56 – 72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
Gauge equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 6/0 | 0.7 | 0.070 – 0.099 mm (indicative according to Pharmacopoeia) |
Equivalences and cross-references
Polyglactin 910 is the most widely used medium-duration multifilament absorbable in the surgical market. This PREMISUT Prime suture is equivalent in composition, absorption profile and mechanical behaviour to the main commercial ranges of braided polyglactin 910, which facilitates its approval in technical specifications and the replacement of references from other manufacturers:
| Manufacturer / commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (braided coated polyglactin 910, violet or colourless) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratorio Aragó (Premisut range) | Braided multifilament polyglactin 910 with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, the same configuration in undyed colour corresponds to reference P1L21DS1260, and the standard quality version (not Prime) to 1L11DS1260. In USP 6/0 gauge with DS12 needle, it is also available in the polyglycolic acid (PGA) family, with longer absorption (60-90 days), under reference AMP111DS1260. The equivalences indicated are for guidance; for a formal replacement of references, please consult our technical-commercial department.
Selection tips and variants of interest
The USP 6/0 gauge (metric 0.7) is indicated for very delicate tissues: fine skin, mucous membranes and ophthalmic surgery, where a small-diameter thread with good initial strength is required. The ⅜ circle needle with reverse cutting triangular point is especially recommended for firm or difficult-to-penetrate tissues, where control and high puncture capacity without tearing are required.
| Reference | Variant |
|---|---|
| P1L11DS1260 | PGLA Prime, DS12 mm needle, USP 6/0, violet, 45 cm (current product) |
| P1L21DS1260 | PGLA Prime, DS12 mm needle, USP 6/0, undyed, 45 cm (same configuration in undyed) |
| 1L11DS1260 | Standard PGLA, DS12 mm needle, USP 6/0, violet, 45 cm (standard quality) |
| P1L11DS1460 | PGLA Prime, DS14 mm needle, USP 6/0, violet, 45 cm (larger needle) |
| P1L11DS1660 | PGLA Prime, DS16 mm needle, USP 6/0, violet, 45 cm (larger needle) |
| P1L11DS1250 | PGLA Prime, DS12 mm needle, USP 5/0, violet, 45 cm (finer gauge) |
| P1L11DS1240 | PGLA Prime, DS12 mm needle, USP 4/0, violet, 45 cm (thicker gauge) |
| AMP111DS1260 | Multifilament PGA, DS12 mm needle, USP 6/0, violet, 45 cm (absorption 60 to 90 days) |
For maximum visibility in the field, the violet version is the most suitable; if greater aesthetic discretion is preferred, the same reference can be requested in undyed colour. If the protocol requires longer tensile support, consider the absorbable monofilament lines; if, on the other hand, faster absorption is sought, consult the PGA range of the same family. All references are supplied in boxes of 12 units.
As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours, contact our technical-commercial team at Cahnos.





Reviews