Description
1. Product Presentation
The multifilament absorbable suture PREMISUT Polyglactin 910 (PGLA) Prime quality, reference P1L11DS1250, is the professional reference solution for B2B supply to operating theatres, ophthalmic clinics, minor surgery practices and purchasing centres. It combines a synthetic copolymer with predictable clinical behaviour, exceptional handling and excellent knot security in tissue approximation, ligatures and ophthalmic surgery.
Its ⅜ circle needle with 12 mm reverse cutting triangular point (DS12) ensures firm, controlled penetration even in non-compliant tissues, while the 45 cm violet non-channeled thread offers optimal visibility over the surgical field and smooth glide during suturing. This is a synthetic absorbable medical device, sterile, single-use and non-reesterilizable, with an excellent cost-performance ratio for the continuous supply of your centre.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a non-channeled finish. This configuration provides a regular surface that facilitates thread passage through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 5/0 (metric 1).
Absorption occurs by hydrolysis, i.e., degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance.
The ⅜ circle needle with reverse cutting triangular point penetrates firm and fibrous tissues with controlled trauma, avoiding tears; therefore it is especially indicated in ophthalmic surgery (sclera), skin and mucous membranes. The violet colour facilitates thread tracking throughout the procedure. The product is supplied sterile by ethylene oxide (EtO) and must not be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference P1L11DS1250
| Parameter | Specification |
|---|---|
| Brand / Range | PREMISUT (Prime quality, premium range) |
| Reference (SKU) | P1L11DS1250 |
| Material | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided multifilament, non-ribbed |
| Gauge | USP 5/0 (metric 1) |
| Thread colour | Violet |
| Thread length | 45 cm |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting (inverted triangular) |
| Needle size | DS12 (12 mm) Prime |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (EtO), single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention and absorption profile
| Time point | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56 – 72 days (hydrolysis) |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 5/0 | 1 | 0.10 – 0.149 mm (indicative according to Pharmacopoeia) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglactin 910 is the most widely used medium-term absorbable multifilament in the surgical market. This PREMISUT Prime suture is equivalent in composition, absorption profile and mechanical behaviour to the main commercial ranges of braided polyglactin 910:
| Manufacturer / commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (braided coated polyglactin 910, violet or colourless) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratorio Aragó (Premisut range) | Braided multifilament polyglactin 910 with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, the same configuration with DS12 needle is available in USP 4/0 (P1L11DS1240) and USP 6/0 (P1L11DS1260). In the polyglycolic acid (PGA) family, with slightly longer absorption (60-90 days), the reference AMP111DS1250 stands out. The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 5/0 (metric 1) is indicated for delicate tissues: thin skin, mucosa, subcutaneous tissue and ophthalmic surgery procedures. The DS12 reverse cutting triangular point needle is especially recommended for firm or difficult-to-penetrate tissues, where the needle passage must be clean and without tears.
| Reference | Variant |
|---|---|
| P1L11DS1240 | PGLA Prime, DS12 mm needle, USP 4/0, violet, 45 cm (larger gauge) |
| P1L11DS1260 | PGLA Prime, DS12 mm needle, USP 6/0, violet, 45 cm (finer gauge) |
| P1L11DS1650 | PGLA Prime, DS16 mm needle, USP 5/0, violet, 45 cm (larger needle) |
| P1L11DS1950 | PGLA Prime, DS19 mm needle, USP 5/0, violet, 45 cm |
| P1L12DS1650 | PGLA Prime, DS16 mm needle, USP 5/0, violet, 75 cm (longer thread length) |
| AMP111DS1250 | PGA multifilament, DS12 mm needle, USP 5/0, violet, 45 cm (absorption 60 to 90 days) |
For maximum visibility in the field, the violet version is the most suitable; if greater aesthetic discretion is preferred, the same reference can be ordered in undyed colour. All references are supplied in a box of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team at Cahnos.





Reviews