Description
1. Commercial Introduction
The absorbable suture PREMISUT of Polyglactin 910 (PGLA), reference 1L12DS1640, is the reference solution for professionals seeking a synthetic surgical thread with predictable clinical behaviour, excellent handling and high knot security. Its ⅜ circle needle with a 16 mm (DS16) reverse cutting triangular point offers firm, controlled penetration even in non-compliant tissues, while the braided, grooved thread in violet ensures optimal visibility on the surgical field, smooth sliding and reliable knot tying.
It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for B2B procurement in operating theatres, ophthalmology practices, purchasing centres and healthcare distributors. Commercial presentation in a box of 12 units.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved (coated) finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knotting, even in fine gauges such as USP 4/0 (metric 1.5).
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ⅜ circle needle with a reverse cutting triangular point penetrates firm and fibrous tissues with controlled trauma, avoiding tears; it is therefore especially indicated in ophthalmic surgery (sclera), skin and mucous membranes. The violet colour improves thread visibility on the surgical field. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference 1L12DS1640
| Parameter | Specification |
|---|---|
| Brand / Range | PREMISUT |
| Reference (SKU) | 1L12DS1640 |
| Material | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 4/0 (metric 1.5) |
| Thread colour | Violet grooved |
| Thread length | 75 cm |
| Needle shape | ⅜ (3/8) circle |
| Tip type | Reverse cutting triangular (inverted triangular) |
| Needle size | 16 mm (DS16) |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (EtO), single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56-72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Polyglactin 910 is the most widely used medium-duration multifilament absorbable in the surgical market. This suture PREMISUT is equivalent in composition and clinical behaviour to the main commercial ranges of polyglactin 910, maintaining the same absorption profile (56-72 days) and tensile strength retention:
| Manufacturer / commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent with the same configuration (triangular needle DS16 mm, USP 4/0 gauge and 75 cm) in colourless is reference 1L22DS1640, and the premium Prime version is P1L12DS1640. The equivalences indicated are for guidance only; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue and the necessary gauge according to the anatomical area. USP 4/0 (metric 1.5) is indicated for delicate tissues with moderate tension: skin, mucous membranes, subcutaneous tissue and ophthalmic surgery. The reverse cutting triangular point needle is recommended when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis, sclera). For maximum visibility in the field, the grooved violet version is the most suitable; if greater aesthetic discretion is preferred, request the same configuration in colourless (1L22DS1640).
| Reference | Variant |
|---|---|
| 1L12DS1640 | PGLA, DS16 mm needle, USP 4/0, violet, 75 cm (current product) |
| 1L22DS1640 | PGLA, DS16 mm needle, USP 4/0, colourless, 75 cm (colourless variant) |
| P1L12DS1640 | PGLA Prime, DS16 mm needle, USP 4/0, violet, 75 cm (superior quality) |
| 1L12DS1650 | PGLA, DS16 mm needle, USP 5/0, violet, 75 cm (finer gauge) |
| 1L12DS1630 | PGLA, DS16 mm needle, USP 3/0, violet, 75 cm (larger gauge) |
| 1L12DS1940 | PGLA, DS19 mm needle, USP 4/0, violet, 75 cm (larger needle) |
| AM112DS1640 | PGA, DS16 mm needle, USP 4/0, violet, 75 cm (absorption from 60 to 90 days) |
All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours made to order, contact our technical-commercial team at Cahnos.





Reviews