Description
1. Introduction
The Absorbable Multifilament PGLA (Polyglactin 910) Suture from the Prime line, reference P1L13HRT3610, is the reference solution for the professional seeking a surgical thread with predictable behaviour, excellent handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery. Its ½ circle needle with cylindrical body and 36 mm trocar point (HRT36) combines high penetration power with low tissue trauma, while the 90 cm violet grooved thread ensures optimal visibility over the surgical field.
It is a synthetic, absorbable, sterile and single-use medical device, with a very competitive price-quality ratio for the B2B supply of operating theatres, ophthalmic clinics and purchasing centres. Commercial presentation in a box of 12 units and a minimum order of 30 boxes, ensuring the continuous supply of your healthcare centre.
2. Technical explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in medium gauges such as USP 0 (metric 3.5).
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes the suture ideal for tissues requiring wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ½ circle needle with cylindrical body and 36 mm trocar point (tapercut) penetrates tissues of moderate or slightly fibrous tension with controlled trauma. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L13HRT3610
| Characteristic | Specification |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (Premisut range) |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Violet |
| Needle shape | ½ circle, cylindrical body |
| Tip type | Trocar / Tapercut |
| Needle size | HRT 36 mm |
| Thread length | 90 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L13HRT3610 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglactin 910 is one of the most well-established synthetic absorbable suture raw materials on the market and clinically corresponds to the same chemical family used by international reference lines:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle needles (470xx series and HRT/HS series) |
Within the Cahnos catalogue, its direct equivalent in configuration and needle is reference P1L13HRT3601 (USP 1, violet, 90 cm), and the colourless version of the same family is P1L23HRT3601. In the polyglycolic acid (PGA) family, the performance equivalent with the same HRT36 needle is AMP113HRT3610 (USP 0, violet, 90 cm), with an absorption profile of 60 to 90 days.
5. Selection tips and variants of interest
USP 0 gauge is ideal for tissues with moderate-medium tension: fascia, aponeurosis, abdominal wall, subcutaneous tissue and ligatures of medium-calibre vessels. The 36 mm HRT trocar point needle is especially recommended in firm or slightly fibrous tissues and in ophthalmic surgery, where the passage of the needle must be clean and without tearing. If a fully atraumatic conical point is preferred, HR versions of 36 mm are available in the same range.
| Reference | Description |
| P1L13HRT3610 | PGLA Prime 1/2 circle trocar point HRT36 mm, USP 0, violet, 90 cm (current reference) |
| P1L13HRT3601 | PGLA Prime 1/2 circle trocar point HRT36 mm, USP 1, violet, 90 cm (larger gauge) |
| P1L13HRT3620 | PGLA Prime 1/2 circle trocar point HRT36 mm, USP 2/0, violet, 90 cm (smaller gauge) |
| P1L13HRT3630 | PGLA Prime 1/2 circle trocar point HRT36 mm, USP 3/0, violet, 90 cm (fine gauge) |
| P1L23HRT3601 | PGLA Prime 1/2 circle trocar point HRT36 mm, USP 1, colourless, 90 cm (colourless version) |
| P1L13HR3610 | PGLA Prime 1/2 circle conical point HR36 mm, USP 0, violet, 90 cm (atraumatic point) |
| AMP113HRT3610 | PGA Prime 1/2 circle trocar point HRT36 mm, USP 0, violet, 90 cm (absorption 60-90 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure the continuous supply of your healthcare centre. For longer force retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. For special B2B conditions and volume orders, contact our technical-commercial team.