We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA (Polyglactin 910) 1/2 Circle Cylindrical Needle Trocar Point HRT 17 mm – USP 4/0 – 70 cm – Violet – Ref. 1L18HRT1740

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable multifilament suture of Polyglactin 910 (PGLA) with a ½ circle needle with cylindrical body and HRT trocar point (tapercut) of 17 mm. Grooved braided thread of USP 4/0 gauge and 70 cm length, violet colour, high visibility in the field. Absorption by hydrolysis between 56 and 72 days with 75% tension retention at 2 weeks. Sterilised by ethylene oxide, presentation in a box of 12 units. Reference: 1L18HRT1740. Price per box of 12 units. Minimum order: 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L18HRT1740

Description

1. Commercial Introduction

The absorbable multifilament suture of Polyglactin 910 (PGLA) from the Premisut range is the reliable and cost-effective solution for the closure of soft tissues, ligatures and ophthalmic surgery procedures. Its configuration with a ½ circle needle with cylindrical body and HRT trocar point of 17 mm combines an atraumatic passage with precise penetration, while the violet braided thread of 70 cm offers excellent handling, secure knotting and optimal visibility even in reduced surgical fields. A product designed for operating theatres, ophthalmologists and ambulatory major surgery units that seek constant quality and stable supply.

2. Technical Explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, configured as a braided and coated multifilament (grooved surface) that facilitates sliding through tissue and smooth knot seating. Its absorption occurs by hydrolysis —not by enzymatic action— which guarantees a predictable reabsorption rate between 56 and 72 days and minimal tissue reaction. The ½ circle needle with cylindrical body and trocar point (tapercut) is especially indicated for soft tissues of certain resistance, since the sharp point initiates penetration and the cylindrical body separates the fibres without cutting them, reducing trauma and leakage through the wound. The USP 4/0 (metric 1.5) gauge is ideal for approximation of fine tissues, ophthalmic surgery, plastic surgery, paediatric surgery and ligatures.

3. Technical Specifications

Composition Polyglactin 910 (copolymer of 90% glycolide and 10% L-lactide) braided and coated multifilament
Structure Grooved multifilament (braided and coated)
Colour Violet (high visibility)
Absorption By hydrolysis, between 56 and 72 days
Tensile strength 75% at 2 weeks | 50% at 3 weeks | 30% at 4 weeks
USP size 4/0 (metric 1.5)
Thread length 70 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Trocar / tapercut
Needle size HRT 17 mm
Sterilisation Ethylene oxide
Brand Premisut
Reference 1L18HRT1740
Presentation Box of 12 units
Minimum order 30 boxes

4. Equivalences and Cross-References

Polyglactin 910 is a widely standardised material in the market of synthetic absorbable sutures. This reference Premisut is equivalent to the Vicryl® range (Ethicon) and to the Safil® range (B.Braun), as well as to the Polyglactin 910 line from Laboratorio Aragó (range 4xxxx), with practically identical absorption and tension retention profiles (absorption 56–72 days; retention 75% at 2 weeks, 50% at 3 weeks and 25–30% at 4 weeks). It is an alternative of comparable quality at a significantly lower cost, ideal for institutional supply contracts and purchasing centres.

5. Selection tips and variants of interest

For very lax tissues or mucous membranes choose the conical point version (taperpoint); for denser tissues or with some fibrosis keep this trocar point configuration, which facilitates entry without tearing. If you prefer a less visible suture, you have the colourless variant of the same needle and gauge (ref. 1L28HRT1740). Other gauges are also available: 3/0 (ref. 1L18HRT1730), 6/0 with HR17 needle (ref. 1L18HR1760) or short 13 mm needle (ref. 1L18HR1340), as well as double needle versions for ophthalmic surgery (ref. 1L18HRT4001-2). Consult the data sheet of each reference and the minimum order conditions to ensure the best centralised supply.

Additional information

Brand

Premisut

Material

Polyglactin 910 (PGLA) – copolymer 90% glycolide / 10% L-lactide

Structure

Braided grooved coated multifilament

USP size

4/0 (metric 1.5)

Needle body

Cylindrical

Sterilisation

Ethylene oxide

Presentation

Box of 12 units

Minimum order

30 boxes

Indications

Tissue approximation, ligatures and ophthalmic surgery

Medida de aguja

HRT 17

Usp

4/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA (Polyglactin 910) 1/2 Circle Cylindrical Needle Trocar Point HRT 17 mm – USP 4/0 – 70 cm – Violet – Ref. 1L18HRT1740”

Your email address will not be published. Required fields are marked *