We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 USP 2/0, 1/2 Circle Trocar Point (Tapercut) Needle HRT 26 mm Prime, Violet Thread 70 cm

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable suture in multifilament polyglactin 910 (PGLA) from the Premisut Prime line: ½ circle cylindrical trocar-point (tapercut) needle of 26 mm, 70 cm violet fluted thread and USP 2/0 gauge. Absorption by hydrolysis in 56–72 days, with tensile retention of 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks. Ref. P1L18HRT2620. Price per box of 12 units; minimum order of 30 boxes.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18HRT2620

Description

1. Product Presentation

The PGLA Prime multifilament absorbable suture (Ref. P1L18HRT2620) from the Premisut line is a synthetic suture made of polyglactin 910 designed for the professional who demands secure closure, reliable knotting and fully predictable absorption. It incorporates a ½ circle cylindrical trocar-point (tapercut) needle of 26 mm, 70 cm violet fluted thread and USP 2/0 gauge. It is supplied in a box of 12 units, with a minimum order of 30 boxes, and is a reference option for tissue approximation, ligatures and ophthalmic surgery.

2. Technical explanation

Polyglactin 910 is a synthetic copolymer composed of 90% glycolide and 10% L-lactide, which degrades in the body by hydrolysis over an interval of 56 to 72 days, with a predictable absorption rate and minimal tissue reaction. Its braided multifilament structure provides flexibility, excellent tensile strength and great security in knot tying, with reduced memory effect.

The thread has a fluted violet finish that makes it easy to locate on the surgical field. The ½ circle trocar-point needle (tapercut geometry) combines a cylindrical body with a cutting point, allowing it to pass through tissues of some resistance with moderate effort and minimising tissue tearing as the strand passes through. It is the usual configuration in ophthalmic surgery and in the approximation of moderately dense soft tissues.

The product is sterilised by ethylene oxide and is single-use, guaranteeing the microbiological safety of the material in each procedure.

3. Technical Specifications

General data

Characteristic Specification
Material Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide)
Structure Braided multifilament
Thread colour Violet grooved
Gauge USP 2/0
Thread length 70 cm
Sterilisation Ethylene oxide
Absorption By hydrolysis, 56–72 days
Quality Prime (line Premisut)

Tensile strength profile

Period Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %

Needle configuration

Configuration Value
Needle shape 1/2 circle
Body Cylindrical
Tip Trocar (tapercut)
Needle size 26 mm (HRT 26)
Needle type HRT 26 Prime

Presentation

  • Box of 12 units.
  • Minimum order: 30 boxes.
  • Reference: P1L18HRT2620.

4. Equivalences and Cross-References

Within the family of absorbable polyglactin 910 (PGLA) sutures, this reference is clinically interchangeable with braided multifilament polyglactin 910 sutures from other manufacturers (Vicryl-type lines from Ethicon/Johnson & Johnson, Surgicryl from SMI or Assucryl 910 from Assut), provided the same USP gauge, thread length and needle configuration are respected.

In the Cahnos catalogue, this Prime version has its standard-quality equivalent in Ref. 1L18HRT2620 (same HRT 26 needle, 2/0 gauge and 70 cm strand) and its high-visibility dark needle version in Ref. P1L18HR2620VB (HR 26 mm VisiBlack needle).

5. Selection tips and variants of interest

  • For medium-density tissues and closure of surgical planes, USP 2/0 gauge offers an optimal balance between strength and manageability.
  • For finer planes or higher-precision surgeries, consider the 3/0 and 4/0 gauges from the same family.
  • If you prefer maximum needle visibility on dark or bloody tissues, choose the VisiBlack version.
  • Recommended variants: P1L18HRT2630 (3/0 gauge), P1L18HR2640 (4/0 gauge, HR 26 needle), P1L18HR2220VB (2/0, VisiBlack HR 22) and 1L18HRT2620 (standard quality).
  • Keep the original packaging in a dry, cool place, respect the expiry date and handle the strand with gloves to avoid altering its mechanical properties.

Additional information

Reference

P1L18HRT2620

Brand

Premisut Prime

Material

Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide)

Thread colour

Violet grooved

Needle size

26 mm (HRT 26)

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 12 units

Minimum order

30 boxes

Intended use

Tissue approximation, ligatures and ophthalmic surgery

Medida de aguja

HRT 26

Usp

2/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Estructura hilo

Braided multifilament

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 USP 2/0, 1/2 Circle Trocar Point (Tapercut) Needle HRT 26 mm Prime, Violet Thread 70 cm”