We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture – ½ Circle Cylindrical Trocar Point Needle HRT 40 mm, USP Gauge 0, Violet Thread 90 cm, Ref. P1L13HRT4010

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament polyglactin 910 (PGLA) suture of Prime quality from the Premisut range, with a ½ circle needle, cylindrical body and trocar point (tapercut) of 40 mm (HRT 40). USP gauge 0, grooved violet thread of 90 cm, sterile by ethylene oxide and with predictable absorption by hydrolysis between 56 and 72 days. Ideal for tissue approximation, ligatures and ophthalmic surgery, with excellent tensile strength and secure knot tying. Reference P1L13HRT4010. Presentation in a box of 12 units; minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L13HRT4010

Description

1. Introduction

The absorbable multifilament polyglactin 910 (PGLA) suture of Prime quality is the reliable choice for surgical teams seeking a high-performance synthetic thread at a competitive price. It comes with a ½ circle needle, cylindrical body and trocar point (tapercut) of 40 mm (HRT 40 mm), USP gauge 0 and violet thread of 90 cm.

Each unit is supplied sterile and ready to use, with the professional distribution warranty of Cahnos for hospitals, private clinics and wholesalers in the sector. Especially indicated for tissue approximation, ligatures and ophthalmic surgery, where precision, manageability and predictable absorption are required. Reference P1L13HRT4010, with a minimum order of 30 boxes.

2. Technical explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure with a grooved finish gives it great flexibility, low memory and a low coefficient of friction that favours thread sliding and knot tying with maximum safety.

The thread is absorbed by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, allowing a constant and predictable loss of strength during healing (75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks). It presents minimal tissue reaction and excellent tensile strength, with an ideal profile for soft tissues that require wound support during the first weeks.

The ½ circle needle with cylindrical body and trocar point (tapercut) combines a rounded body that passes through tissue with minimal injury and a cutting point that allows penetration of fibrous and dense tissues, such as the sclera, with less effort. The violet colouration of the thread guarantees optimal visibility throughout the procedure. Sterilisation by ethylene oxide, single-use product.

3. Technical Specifications

General characteristics

Characteristic Specification
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Colour Violet
Gauge USP 0
Thread length 90 cm
Needle: shape ½ circle
Needle: body Cylindrical
Needle: point Trocar (tapercut)
Needle: radius / code HRT 40 mm, Prime quality
Mounting Needle threaded with suture
Sterilisation Ethylene oxide (EO), single-use

Absorption and strength profile

Time Remaining tensile strength
2 weeks 75% of initial tensile strength
3 weeks 50% of initial tensile strength
4 weeks 30 % of initial tensile strength
Total absorption 56-72 days, by hydrolysis

Presentation and ordering conditions

Value Value
Reference P1L13HRT4010
Presentation Box of 12 units
Minimum order 30 boxes

4. Equivalences and Cross-References

This polyglactin 910 suture is part of the family of braided synthetic absorbable sutures of medium absorption, clinically equivalent to the reference polyglactin 910 sutures on the international market, such as Vicryl from Ethicon or Surgicryl / Safil from B. Braun, among others.

Within the Cahnos catalogue, it is directly related to the following references of the same family:

  • P1L13HRT4020 – same HRT 40 mm trocar point needle and same 90 cm thread, USP gauge 2/0.
  • P1L13HRT4820 – HRT 48 mm trocar point needle, gauge 2/0, violet thread of 90 cm.
  • P1L13HR4010 – HR 40 mm conical point needle (taperpoint), gauge 0, violet thread of 90 cm.
  • P1L18HRT4810 – HRT 48 mm trocar point needle, gauge 0, violet thread of 70 cm.
  • AMP113HRT4010 – PGA Prime multifilament suture, same HRT 40 mm needle, gauge 0, thread of 90 cm.
  • P1L13HRN4010H – HRN 40 mm blunt point Prime Heavy needle, gauge 0, violet thread of 90 cm.

5. Selection tips and variants of interest

In ophthalmic surgery, prioritise ½ circle needles: the trocar point is ideal for the sclera and fibrous tissues, while the conical point (taperpoint) is reserved for soft tissues. USP gauge 0 offers an optimal balance between strength and delicacy for fine tissue planes and approximation techniques; gauges 2/0 and 3/0 are intended for more delicate tissues and gauge 1 for areas subject to greater traction.

Verify the needle radius (HRT 36, 40 or 48 mm) according to the depth and surgical area; the 150 cm loop formats are ideal for continuous suturing or anchoring without rethreading. As it is a sterile single-use product, check the integrity of the packaging before each procedure and respect the traceability required by the centre.

Consult our commercial team for special volume conditions: the minimum order is 30 boxes, with scheduled deliveries for hospitals and purchasing centres.

Additional information

Material

Polyglactin 910 (PGLA) – copolymer 90 % glycolide / 10 % L-lactide

Structure

Multifilament braided fluted

Gauge

USP 0

Needle body

Cylindrical

Needle size

HRT 40 mm, Prime quality

Mounting

Needle threaded with suture

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Minimum order

30 boxes

Intended use

Tissue approximation, ligatures and ophthalmic surgery

Reference

P1L13HRT4010

Medida de aguja

HRT 40

Usp

0

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture – ½ Circle Cylindrical Trocar Point Needle HRT 40 mm, USP Gauge 0, Violet Thread 90 cm, Ref. P1L13HRT4010”

Your email address will not be published. Required fields are marked *