We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA (Poliglactin 910) Suture Premisut – 1/2 Circle Cylindrical Needle Trocar Point Tapercut HRT 17 mm – USP 4/0 Gauge – Colourless Thread 70 cm – Ref. 1L28HRT1740 – Box of 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable multifilament Poliglactin 910 (PGLA) suture with a ½ circle needle, cylindrical body and 17 mm trocar (Tapercut) HRT point. USP 4/0 gauge (metric 1.5) and colourless, braided and grooved 70 cm thread, ideal for tissue approximation, ligatures and ophthalmic surgery. Predictable absorption by hydrolysis between 56 and 72 days, with 75 % retention of tensile strength at 2 weeks. Sterilised by ethylene oxide, minimal tissue reaction, excellent tensile strength and knot security. Ref. 1L28HRT1740, presentation in a box of 12 units and minimum order of 30 boxes. Price per box.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L28HRT1740

Description

1. Commercial Introduction

The absorbable multifilament Poliglactin 910 (PGLA) suture from the Premisut range is the reliable and cost-effective solution for closing soft tissues, ligatures and ophthalmic surgery procedures. Its configuration with a ½ circle needle, cylindrical body and 17 mm trocar (Tapercut) HRT point combines an atraumatic passage with precise penetration, while the 70 cm braided and colourless thread offers excellent handling, secure knotting and optimal visibility of the surgical field. A product designed for operating theatres, ophthalmology units and major ambulatory surgery that seek consistent quality and stable supply with B2B conditions for purchasing centres and institutional contracts.

2. Technical Explanation

Poliglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, configured as a braided and coated multifilament (grooved surface) that facilitates the passage of the thread through tissue and smooth knot seating. Its absorption occurs by hydrolysis (and not by enzymatic action), ensuring a predictable resorption rate of between 56 and 72 days and minimal tissue reaction. The ½ circle needle with cylindrical body and trocar (Tapercut) point is especially indicated for soft tissues of a certain resistance: the cutting point initiates penetration and the cylindrical body separates the fibres without cutting them, reducing trauma and leakage through the wound. The USP 4/0 gauge (metric 1.5) is ideal for approximating fine tissues, ophthalmic surgery, plastic surgery, paediatric surgery and ligatures. Sterile, single-use product, sterilised by ethylene oxide.

3. Technical Specifications

General characteristics of reference 1L28HRT1740:

Parameter Specification
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided and coated multifilament (grooved)
Quality Normal (Premisut range)
Gauge USP 4/0 (metric 1.5)
Thread length 70 cm
Thread colour Colourless (minimal visual interference)
Needle shape 1/2 circle
Needle body Cylindrical
Needle tip Trocar (Tapercut)
Needle size 17 mm (HRT 17)
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide, single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) 1L28HRT1740

Tensile strength retention profile:

Period Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Total absorption by hydrolysis 56-72 days

4. Equivalences and Cross-References

Poliglactin 910 is a widely standardised material in the market for synthetic absorbable sutures. This Premisut reference is clinically in the same family as the leading absorbable braided sutures on the European market: Ethicon (Johnson & Johnson) Vicryl®, B. Braun Safil®, Medtronic (Covidien) Polysorb®, SMI Surgicryl® 910, Assut Assucryl® 910 and the Poliglactin 910 line from Laboratorio Aragó (4xxxx range), with practically identical absorption and tension retention profiles. Within the Cahnos catalogue, the direct equivalent in violet with an identical configuration (17 mm HRT trocar needle, USP 4/0 gauge and 70 cm thread) is reference 1L18HRT1740; the Prime quality version with the same geometry and colourless colour is reference P1L28HRT1740 (and its violet variant P1L18HRT1740).

5. Selection tips and variants of interest

The USP 4/0 gauge (metric 1.5) is the most suitable for fine and delicate tissues: ophthalmic, plastic and paediatric surgery, ligatures and approximation of tissues under moderate tension. The trocar (Tapercut) point is ideal for moderately dense tissues; if you work with mucous membranes or very lax tissues, consider the conical Taperpoint point variants (ref. 1L28HR1740). It also offers other gauges and presentations in the same family: 3/0 (ref. 1L18HRT1730), 5/0 colourless (ref. 1L28HR1750), 26 mm trocar needle (ref. 1L18HRT2630) and alternatives in polyglycolic acid PGA with the same 17 mm needle (ref. AM128HRT1740 colourless and AM118HRT1740 violet). Consult your Cahnos advisor for minimum order conditions, volume pricing and supply contracts for hospitals and purchasing centres.

Additional information

Material

Polyglactin 910 (PGLA) – copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided and coated multifilament (grooved)

Quality

Normal (Premisut range)

USP size

4/0 (metric 1.5)

Needle body

Cylindrical

Needle size

17 mm (HRT 17)

Sterilisation

Ethylene oxide, single-use

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Brand

Premisut

Reference

1L28HRT1740

Medida de aguja

HRT 17

Usp

4/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA (Poliglactin 910) Suture Premisut – 1/2 Circle Cylindrical Needle Trocar Point Tapercut HRT 17 mm – USP 4/0 Gauge – Colourless Thread 70 cm – Ref. 1L28HRT1740 – Box of 12 units”