Description
1. Product Presentation
At Cahnos we offer this absorbable monofilament suture of poliglecaprone 25 (PGCL) from the Prime line (PREMISUT), reference AMP328GS4840, a professional solution for B2B supply to operating theatres, procurement centres and general surgery departments. The presentation includes a straight needle with triangular point and conventional cutting edge of 48 mm (model GS48), colourless thread of 70 cm in USP gauge 4/0 and a non-grooved surface that minimises resistance when passing through tissue. Predictable clinical behaviour, excellent tensile strength, reliable knot tying and minimal tissue reaction, with special conditions for volume contracts and hospital supply.
2. Technical explanation of the material and procedure
Poliglecaprone 25 (PGCL) is a synthetic copolymer of glycolide and ε-caprolactone presented in a monofilament structure, which gives it a smooth, non-grooved surface that passes through tissue with minimal resistance, reducing tissue reaction and sawing effect. Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the thread maintains mechanical support during the critical phase of wound healing (60% of strength at one week and 30% at 2 weeks) and is reabsorbed progressively and in a controlled manner over a range of 90 to 120 days, covering protocols that require longer support duration than other synthetic absorbables.
The straight GS48 needle (48 mm), with a triangular conventional cutting point, facilitates penetration into firm tissues and allows manual suturing with absolute control of the path, being especially useful for approximation stitches, superficial continuous sutures and ligatures with direct access to the surgical field in precision surgery. The colourless colour of the strand favours aesthetic discretion without interfering with visualisation of the field. The product is supplied sterile by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
| Parameter | Specification |
| Reference (SKU Cahnos) | AMP328GS4840 |
| Tariff reference (PREMISUT) | P328GS4840 |
| Brand / Quality | PREMISUT – Prime line |
| Material | Polyglecaprone 25 (PGCL), synthetic absorbable monofilament |
| Thread structure | Monofilament, non-grooved surface |
| Gauge / USP size | USP 4/0 (metric 1.5) |
| Thread length | 70 cm |
| Needle shape | Straight |
| Tip type | Triangular – conventional cutting |
| Needle size | 48 mm (model GS48) |
| Thread colour | Undyed (also available violet depending on presentation) |
| Absorption | By hydrolysis, between 90 and 120 days |
| Tensile strength retention | 60 % at 1 week; 30 % at 2 weeks |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (minimum order of 30 boxes) |
Force retention and absorption profile:
| Time point | Strength retention |
| 1 week | 60 % |
| 2 weeks | 30 % |
| Total absorption | 90 – 120 days |
Gauge equivalence (indicative):
| USP size | Metric size | Approximate diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm (indicative according to USP) |
4. Equivalences and Cross-References
Monofilament poliglecaprone 25 (PGCL) is the clinical reference for long-duration synthetic absorbables (90-120 days), and the configuration of straight cutting needle with colourless 70 cm strand is one of the most demanded for manual suturing of fine tissues and ligatures with direct access. The homologous commercial ranges of the same molecule are MONOCRYL® (Ethicon / Johnson & Johnson MedTech), Caprofyl® (SMI), Monoglyde® (Healthium), as well as the poliglecaprone 25 series from Dolphin Sutures, WEGO and CP Medical. In the polyglactin 910 (PGLA) segment, a material from the same clinical family but of different composition (copolymer of glycolide and L-lactide), the ranges Vicryl® (Ethicon), Safil® (B. Braun) and Polysorb™ (Medtronic) are placed.
Verification note: in the USP 3/0 gauge of this same line with GS60 needle (reference AMP328GS6030), the functional coincidence with the Y523H reference of Ethicon MONOCRYL® (straight cutting needle KS 60 mm, colourless, 70 cm) has been consistently confirmed in authorised distributor sources, being a functional category comparison, not interchangeable 1:1. For the specific configuration of this product (straight GS48 needle of 48 mm, USP 4/0 gauge, colourless, 70 cm), no official code from another manufacturer that exactly reproduces all attributes has been found in public sources. There is no equivalence table validated by the manufacturer that cross-references this configuration with references from other commercial houses; consult the technical department of Cahnos before use in tenders or in the direct substitution of references. The cited brands belong to their respective manufacturers and are mentioned only as an equivalence reference.
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: 4/0 is suitable for fine tissues, skin and precision surgery; 3/0 for skin, subcutaneous tissue and approximation of soft tissues with moderate tension; and 2/0 for tissues with greater mechanical demand and ligatures. The straight conventional cutting needle is ideal for approximation sutures and ligation with direct access to the surgical field.
Variants of interest within the Cahnos catalogue in the same USP 4/0 gauge and colourless 70 cm strand: AMP328GS6040 (PGCL Prime, straight GS60 needle of 60 mm, same configuration with longer needle); AM328GS6040 (PGCL standard quality, GS60, USP 4/0, colourless, 70 cm); P1L28GS6040 (PGLA Prime multifilament, GS60, USP 4/0, colourless, 70 cm, absorption 56-72 days) and AMP128GS6040 (PGA Prime multifilament, GS60, USP 4/0, colourless, 70 cm, absorption 60-90 days). If the protocol requires shorter support duration, consider the PGA or PGLA lines with the same needle format.
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or queries about equivalences from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.