Description
Block 1 · Introduction
The absorbable monofilament suture PREMISUT Poliglecaprone 25 (PGCL / Caprolactone) is the technical choice when the procedure requires controlled reabsorption, minimal inflammatory response and an especially smooth passage of the thread through the tissue. In its Prime quality and with XDS precision needle, it offers the professional consistent and predictable performance in soft tissue approximation and ligatures, with the safety of a sterile product ready for use.
Block 2 · Technical explanation
Poliglecaprone 25 is a synthetic copolymer of glycolide and ε-caprolactone that degrades by hydrolysis, without enzymatic activity, ensuring predictable absorption and minimal tissue reaction. Being a monofilament, it reduces bacterial wicking compared with multifilament sutures and facilitates sliding and the formation of secure knots.
- Absorption: by complete hydrolysis, with total mass loss between 90 and 120 days.
- Tensile strength retention: approximately 60% at the first week and 30% at the second, covering the critical healing phase.
- Needle: ⅜ circle, precision reverse cutting triangular point XDS with square body (24 mm), designed for firm penetration with minimal resistance and optimal needle holder control.
- Indications: approximation of soft tissues and ligatures in general, dermatological, plastic and reconstructive surgery, as well as in delicate tissues where a fine gauge is required with a balance between strength and minimal footprint.
Block 3 · Technical specifications
| Parameter | Specification |
|---|---|
| Material | Polyglecaprone 25 (PGCL) · copolymer of glycolide and ε-caprolactone |
| Structure | Synthetic absorbable monofilament |
| Absorption mechanism | Complete hydrolysis |
| Absorption time | 90 – 120 days |
| Tensile strength retention | ≈ 60 % at 1 week · ≈ 30 % at 2 weeks |
| USP size | 4/0 |
| Thread length | 70 cm |
| Colour | Colourless |
| Needle shape | ⅜ circle |
| Needle tip | Precision reverse cutting triangular (XDS) |
| Needle body / section | Square (24 mm length) |
| Sterilisation | Ethylene oxide |
| Quality | Prime |
| Presentation | Box of 12 sterile units |
| Reference Cahnos | AMP328XDS2440 |
Block 4 · Equivalences and cross-references
Poliglecaprone 25 is a material widely established in the international market, where the clinical reference for the category is the MONOCRYL® line from Ethicon. For this specific format (USP 4/0, colourless, monofilament, ⅜ circle reverse cutting needle of 24 mm and 70 cm thread), the reference Y935H (MONOCRYL® poliglecaprone 25, PS-1 24 mm, ⅜ circle, reverse cutting, colourless, 4/0, 70 cm) has been verified against authorised distribution sources.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | MONOCRYL® (polyglecaprone 25) | Y935H | Comparable by category (not interchangeable 1:1) | Same material, gauge 4/0, 70 cm colourless thread and ⅜ circle reverse cutting needle of 24 mm (PS-1). No 1:1 equivalence is declared as it is a different manufacturer; validate in the technical data sheet before substituting in a tender. |
| Ethicon (J&J MedTech) | MONOCRYL® Plus Antibacterial (poliglecaprone 25) | MCP935H | Comparable by category (not interchangeable 1:1) | Same configuration 4/0 · 24 mm · 70 cm colourless, with added antibacterial triclosan. The antibacterial load represents a relevant functional difference. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in a tender. The verification of references Y935H and MCP935H was carried out against the manufacturer’s authorised distribution sources; the factory reference PREMISUT for this article does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before use in specifications. As homologous families in the sector for this category of absorbable monofilament PGCL, MONOCRYL® (Ethicon) and the poliglecaprone 25 lines from Assut Medical and SMI are cited, pending 1:1 technical verification.
Block 5 · Selection advice and variants of interest
- Gauge 4/0: indicated for fine and delicate tissues (dermis, subcutaneous, mucosa) where minimal reaction and good knot strength are sought.
- Variants of the same family at Cahnos: if a shorter needle or a different gauge is required, the PREMISUT PGCL range offers formats of 19, 24, 26 and 30 mm and gauges 2/0, 3/0 and 4/0, in threads of 45, 70 and 75 cm.
- Needle selection criterion: the XDS reverse cutting point with square body is preferable in firm tissues (skin, aponeurosis); for loose or cavitary tissues consider the cylindrical conical point version of the same range.
- Store in a cool, dry place, respecting the expiry date of the sterile packaging, and check the integrity of the blister before each use.





Reviews
There are no reviews yet.