Description
At Cahnos we make available to operating theatres, general surgery departments, gynaecology units, urology and purchasing centres the absorbable monofilament suture of poliglecaprone 25 (PGCL / caprolactone) from the Prime range, factory reference P318HR1740 (SKU AMP318HR1740). This presentation combines a ½ circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17), USP 4/0 gauge and violet thread of 70 cm, in single-needle configuration.
It is a medium-absorption thread (90–120 days), with exceptional handling, high knot security and a very smooth passage through tissue, designed for the professional who needs reliable wound support during the first weeks, with a very competitive quality-price ratio for hospital supply. Synthetic absorbable medical device, sterile and single-use, presented in a box of 12 units.
Technical product explanation
Poliglecaprone 25 is a synthetic absorbable copolymer (glycolide and ε-caprolactone) with a monofilament structure that degrades by hydrolysis, i.e., by cleavage of the polymer chains in contact with organic fluids, over a predictable period of 90 to 120 days and independent of the patient’s enzymatic activity. Being a non-grooved monofilament, the strand has a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence, while maintaining high tensile strength and reliable knot tying during the critical phases of wound healing.
The ½ circle needle with cylindrical body and Taperpoint conical point passes through soft tissues separating the fibres without cutting effect, which makes it especially atraumatic in delicate structures, subcutaneous tissue and approximation of soft tissues. The USP 4/0 gauge (metric 1.5) provides an excellent balance between fineness, manageability and initial resistance. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
Technical specifications
Technical data sheet for reference AMP318HR1740
| Parameter | Specification |
| Reference (SKU Cahnos) | AMP318HR1740 |
| Factory reference | P318HR1740 (PREMISUT POLIGLECAPRONE 25 CAPROLACTONE PGCL PRIME) |
| Range / Quality | Prime (premium range) |
| Material | Polyglecaprone 25 (PGCL / caprolactone), synthetic absorbable monofilament |
| Thread structure | Monofilament, non-channeled |
| Gauge | USP 4/0 (metric 1.5) |
| Thread colour | Violet (high visibility) |
| Needle shape | ½ circle (half circumference) |
| Needle body and point | Cylindrical body, conical Taperpoint tip |
| Needle size | 17 mm (HR 17 Prime) |
| Thread length | 70 cm (1 thread · 1 needle per unit) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 90–120 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures, general surgery, gynaecology, urology and paediatric surgery |
| Presentation | Box of 12 sterile units · minimum order 30 boxes |
Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 1 week | 60 % |
| 2 weeks | 30 % |
| Complete absorption | 90–120 days by hydrolysis |
Complete absorption by hydrolysis between 90 and 120 days, with minimal tissue reaction, excellent initial tensile strength, optimal knot tying and a fully predictable absorption rate. Price per box of 12 units.
Equivalences and cross-references
Poliglecaprone 25 monofilament is one of the most well-established families of synthetic absorbable sutures of medium absorption on the market, with the MONOCRYL® line from Ethicon (Johnson & Johnson MedTech) being the clinical reference in the category. For the USP 4/0 configuration, ½ circle needle with conical point of 17 mm and 70 cm violet strand, the following correspondences have been cross-checked against manufacturer sources and authorised distribution, with the caveat that the commercial assembly of each house presents differences in point finish and presentation, so they are not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | MONOCRYL® – poliglecaprone 25 monofilament, violet, USP 4/0, 70 cm, RB-1 needle of 17 mm, ½ circle, conical point (taper point) | Y304H | Comparable by category (not interchangeable 1:1) | Confirmed in Ethicon catalogue and authorised distribution: they match in material (poliglecaprone 25), USP 4/0 gauge, thread length (70 cm), violet colour, ½ circle shape and needle size (17 mm) with conical point; they differ in point finish (conventional RB-1 taper point versus HR17 Taperpoint) and commercial presentation (boxes of 36 units versus 12 units). It is the closest match as it is a conventional conical needle without darkened finish. Validate in the technical data sheet before substituting in a tender. |
| Ethicon (Johnson & Johnson MedTech) | MONOCRYL® – poliglecaprone 25 monofilament, violet, USP 4/0, 70 cm, RB-1 VisiBlack needle of 17 mm, ½ circle, conical point (taper point) | Y3040H | Comparable by category (not interchangeable 1:1) | Confirmed in Ethicon catalogue and authorised distribution: material, gauge, length, colour, curvature and needle size match; the darkened VisiBlack finish of the needle differs (the present reference is a conventional HR17 needle) and the commercial presentation. Validate in the technical data sheet before substituting. |
There is no equivalence table validated by the manufacturer for an exact 1:1 match with a Taperpoint HR17 conical needle of 17 mm, USP 4/0 gauge and 70 cm violet thread; consult the technical department before using in a tender. As homologous families on the market to verify in their official data sheet before substitution, the MONOCRYL® and MONOCRYL® Plus Antibacterial lines from Ethicon (poliglecaprone 25), Monosyn from B. Braun (glyconate, different degradation kinetics) and medium-absorption absorbable monofilaments from other suppliers (Assut, DemeTECH, SMI) are cited, checking one by one: exact material, USP 4/0 gauge, ½ circle curvature, 17 mm needle size, conical point family, 70 cm thread length, violet colour and CE/MDR regulatory classification.
Selection tips and variants of interest
The USP 4/0 gauge is the standard for fine and low-medium tension tissues: skin, subcutaneous tissue, mucosa, fascia and ligation of fine-calibre vessels, with special utility in paediatric surgery and precision procedures. The violet colour maximises visibility over the surgical field; if a precision point finish is preferred, consider the version with Taperpoint Ultra Plus conical point from the same family, and if greater penetration in firm or slightly fibrous tissues is required, the trocar point versions (Tapercut).
| Reference | Description |
| AMP318HR1740 | PGCL Prime, HR17 needle Taperpoint conical point, USP 4/0, violet, 70 cm (product analysed) |
| AMP318HR1740VB | PGCL Prime, HR17 VisiBlack needle conical point, USP 4/0, violet, 70 cm (VisiBlack finish for maximum visibility) |
| AM318HR1740 | PGCL Normal quality, HR17 needle conical point, USP 4/0, violet, 70 cm (same configuration, standard range) |
| AMP318HRP1740 | PGCL Prime, HRP17 needle conical point Ultra Plus, USP 4/0, violet, 70 cm (precision point) |
| AMP318HR1740-2VB | PGCL Prime, double needle 2xHR17 conical point VisiBlack, USP 4/0, violet, 70 cm (double-armed for continuous suture) |
| AMP318HR1750 | PGCL Prime, HR17 conical point needle, USP 5/0, violet, 70 cm (fine gauge, paediatrics) |
| AMP318HR1760 | PGCL Prime, HR17 needle conical point, USP 6/0, violet, 70 cm (maximum fineness) |
| AMP328HR1730 | PGCL Prime, HR17 needle conical point, USP 3/0, colourless, 70 cm (larger gauge, aesthetic discretion) |
If the procedure requires longer wound support, consider polydioxanone PDO (180–210 days); if a shorter absorption profile is needed, consider PGA (60–90 days). All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the pouch and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or validation of equivalence with other commercial brands, contact our technical-commercial team.





Reviews