Description
1. Commercial Introduction
The multifilament absorbable suture PREMISUT RÁPIDO is the accelerated absorption closure solution for operating theatre services, general and ambulatory surgery, emergency departments, purchasing centres and distributors that need a braided, flexible thread with early and fully predictable loss of tensile strength.
This presentation combines a ⅜ circle needle with a 19 mm reverse cutting triangular point (DS19), gauge USP 3/0 (metric 2) and a 75 cm colourless thread: the ideal configuration for tissue approximation, skin closure, mucous membranes, ligatures and general surgery, with the advantage of not requiring removal in most indications thanks to its rapid reabsorption. Sterile, single-use medical device, in a box of 12 units.
2. Technical explanation
PGAR is a 100% synthetic polymer absorbable by hydrolysis, with a lower molecular weight than conventional PGA, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissue, improves thread sliding and facilitates firm, secure knotting, with excellent first-knot retention and low thread memory.
Its rapid absorption profile is designed for short-duration healing: it retains 50% of tensile strength at 5 days and loses virtually all its resistance at 14 days, with complete absorption between 40 and 45 days via physiological hydrolysis, with minimal tissue reaction. The DS19 needle with reverse cutting triangular point directs the cutting edge away from the wound bed, creating a clean entry hole that preserves the skin edge and prevents the cut from widening: it is the recommended geometry for firm, non-compliant tissues such as skin, fascia and aponeurosis. The colourless colour offers maximum discretion on the surgical field. Sterilisation by gamma radiation; single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics (Ref. 222DS1930 · SKU AM222DS1930)
| Parameter | Specification |
|---|---|
| Range / Brand | PREMISUT RÁPIDO (standard quality) |
| Factory reference | 222DS1930 |
| SKU Cahnos | AM222DS1930 |
| Composition | 100% low molecular weight polyglycolic acid (PGAR), absorbable by hydrolysis |
| Thread structure | Coated braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 3/0 (metric 2, conforming to USP/EP Pharmacopoeia) |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread colour | Colourless |
| Thread length | 75 cm |
| Needle shape | 3/8 circle (approx. 135°) |
| Tip type | Reverse cutting triangular (body and point) |
| Needle size | DS19 (19 mm) |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50% at 5 days · 0% at 14 days |
| Sterilisation | Gamma radiation; sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (minimum order 30 boxes) |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
|---|---|
| 5 days | 50% of initial strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
3.3. Gauge equivalence (USP/EP Pharmacopoeia)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
3.4. Reference code decoding
Reference 222DS1930 breaks down as follows: 222 (75 cm thread in the PGAR RÁPIDO family) + DS19 (⅜ circle needle with 19 mm reverse cutting triangular point, triangular body and point) + 30 (USP 3/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
Rapid absorption polyglycolic acid (PGAR) is one of the most widespread braided absorbable suture families on the market, clinically equivalent at category level to the rapid absorption lines of major manufacturers. The reference shares low molecular weight absorbable material, USP 3/0 gauge, ⅜ circle curvature, 19 mm reverse cutting needle and 75 cm colourless thread with the homologous products listed below. The comparison is declared at category level, not interchangeable 1:1, as the exact polymer, coating or point family differ.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (braided polyglactin 910, low molecular weight, undyed) | W9931 (EMEA, 3/8 circle reverse cutting needle of 19 mm, 75 cm) | Comparable by category (not interchangeable 1:1) | They match USP 3/0 gauge, 75 cm colourless braided thread and ⅜ circle needle with 19 mm reverse cutting; the base polymer differs (polyglactin 910 vs. polyglycolic acid PGAR) and the braid coating. Complete absorption ≈42 days. Code verified in Ethicon EMEA catalogue. |
| B. Braun (Aesculap) | Safil Quick (low molecular weight polyglycolic acid, braided and coated) | C1046421 – USP 3/0, 3/8 circle needle of 19 mm, 70 cm undyed | Comparable by category (not interchangeable 1:1) | Same base material (low molecular weight PGA), gauge and needle size (19 mm); the point family differs (standard cutting vs. reverse cutting), thread length (70 cm vs. 75 cm) and presentation. Code verified in authorised distribution. |
Other homologous lines in the rapid absorption segment are NOVOSYN QUICK (B. Braun), Velosorb Fast (Medtronic/Covidien), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI); they are not included in the table because no verified code is available for the exact combination USP 3/0 / 19 mm needle / reverse cutting / 75 cm thread. Standard VICRYL (absorption 56-72 days) is not comparable to this RAPID version.
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before using in tendering or direct substitution, verifying one by one material, USP gauge, needle size (19 mm), ⅜ curvature, point family (reverse cutting), thread length (75 cm) and colour. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
USP 3/0 gauge (metric 2) offers an ideal balance between initial strength and manageability, indicated for tissues with moderate tension: skin, subcutaneous tissue, mucous membranes and soft tissue closures. The DS19 needle with reverse cutting triangular point is recommended when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis) in medium or small surgical fields. The colourless version offers maximum aesthetic discretion; if you prefer greater visibility, request the same configuration in dyed thread on demand.
| Reference | Variant |
|---|---|
| AM222DS1930 (222DS1930) | PGAR RÁPIDO, DS19 reverse cutting needle, USP 3/0, colourless, 75 cm (this product) |
| AMP222DS1930 (P222DS1930) | PGAR RÁPIDO Prime, same configuration (superior sharpening and finish quality) |
| AM222DS1630 (222DS1630) | PGAR RÁPIDO, DS16 needle, USP 3/0, colourless, 75 cm (shorter needle) |
| AM222DS1940 (222DS1940) | PGAR RÁPIDO, DS19 needle, USP 4/0, colourless, 75 cm (finer gauge) |
| AM222DS1950 (222DS1950) | PGAR RÁPIDO, DS19 needle, USP 5/0, colourless, 75 cm (delicate tissues) |
| AM122DS1930 (122DS1930) | Standard PGA, same needle and gauge, colourless, 75 cm (absorption 60-90 days, greater tensile support) |
| AM2L22DS1930 (2L22DS1930) | PGLAR Polyglactin 910 RAPID, same configuration (absorption 40-45 days) |
| AM322DS1930 (322DS1930) | PGCL monofilament (polyglecaprone 25), same configuration (absorption 90-120 days) |
| AMP222HR2230 (P222HR2230) | PGAR RÁPIDO Prime, ½ circle taperpoint HR22 needle, USP 3/0, colourless, 75 cm (soft tissues) |
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure, keep the batch number for traceability and store in a cool, dry place, protected from sunlight. All references are supplied in boxes of 12 units, with a minimum order of 30 boxes. For special B2B conditions, volume orders or validation of equivalences with other commercial brands, contact the technical-commercial team at Cahnos.





Reviews