Description
1. Commercial Introduction
We make available to operating theatres, general and digestive surgery departments, plastic and reconstructive surgery units, surgical dermatology and purchasing centres the absorbable multifilament suture PREMISUT RÁPIDO (PGAR, rapid-absorption polyglycolic acid), factory reference P228XDS2420, marketed under SKU AMP228XDS2420. This presentation combines a colourless braided thread of 70 cm in USP 2/0 gauge with a precision ⅜ circle needle of 24 mm (XDS24 profile), reverse-cutting triangular point and square body: a format designed for firm, non-distensible tissues requiring clean penetration, minimal trauma and an impeccable aesthetic result. Each unit is delivered sterile, ready for immediate use, in a box of 12 individual sachets.
2. Technical explanation of the material and procedure
The PGAR RÁPIDO suture is a synthetic braided multifilament of rapid-absorption polyglycolic acid, coated with polycaprolactone and calcium stearate. The coating reduces friction when passing through tissue (less sawing effect), facilitates thread sliding and ensures firm, reproducible knot tying, with minimal tissue reaction. Absorption occurs by controlled hydrolysis, a predictable mechanism independent of enzymatic activity, over a period of 40 to 45 days: the thread retains approximately 50% of its tensile strength at 5 days and loses practically all its strength at 14 days, a profile designed to support only the initial healing phase of rapidly consolidating tissues.
The XDS24 needle (24 mm, ⅜ circle curvature) with precision reverse-cutting triangular point and square body concentrates the cutting edge on the outer face of the curvature: it penetrates skin, dense subcutaneous tissue and aponeuroses with minimal resistance, prevents the cut from widening in the puncture bed and improves the aesthetic result, hence its common use in plastic and cosmetic procedures. Sterilisation by gamma radiation; single-use product, not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P228XDS2420
| Parameter | Specification |
| Brand / Quality | PREMISUT RÁPIDO (standard quality; XDS24 precision needle) |
| Factory reference | P228XDS2420 |
| Reference Cahnos (SKU) | AMP228XDS2420 |
| Thread material | 100% rapid absorption polyglycolic acid (PGAR / rapid profile polyglactin) |
| Thread structure | Synthetic absorbable braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 2/0 (metric EP 3), conforming to USP and European Pharmacopoeia |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread length | 70 cm (1 strand / 1 needle per unit) |
| Thread colour | Colourless |
| Needle shape | 3/8 circle (⅜ circular) |
| Tip type | Precision reverse cutting triangular (Reverse Extra Cutting) with square body |
| Needle size | XDS 24 (24 mm) |
| Swaged | 1 needle / 1 thread of 70 cm per unit |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days (rapid absorption) |
| Sterilisation | Gamma radiation; sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, skin closure and general surgery; commonly used in plastic and cosmetic surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforms to USP and European Pharmacopoeia (EP) gauges |
| Storage | Below 30 °C, away from moisture and direct sunlight |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% of the initial tensile strength |
| Complete absorption | 40 – 45 days, by hydrolysis |
3.3. Gauge equivalence according to USP / EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
Reference P228XDS2420 corresponds to the official nomenclature of the PREMISUT range (XDS24 profile: 24 mm ⅜ circle needle with precision reverse-cutting triangular point and square body, USP 2/0 gauge, colourless 70 cm thread) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering. The rapid-absorption braided multifilament category (rapid polyglactin/PGA profile, 40–45 days) has in Ethicon’s VICRYL RAPIDE® line (Johnson & Johnson MedTech) its international clinical reference, alongside homologous families from other manufacturers. The following correspondences have been verified against official catalogue or authorised distribution, both comparable by category and not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | Coated VICRYL® (polyglactin 910) undyed multifilament, USP 2/0, 70 cm, FS-1 24 mm needle, ⅜ circle, reverse cutting | J443H | Comparable by category (not interchangeable 1:1) | Confirmed in authorised distribution: they match in multifilament structure, polymer of the polyglactin 910 family, USP 2/0 gauge, colourless colour, 70 cm length and 24 mm ⅜ circle reverse-cutting needle configuration. They differ in absorption profile (standard VICRYL® retains tensile strength for longer than rapid PGAR) and coating. Validate in technical data sheet/IFU before substituting in tender. |
| Ethicon (J&J MedTech) | Coated VICRYL RAPIDE® (polyglactin 910) undyed multifilament, USP 2/0, 70 cm, SH-1 Plus tapered needle, ⅜ circle | V62H | Comparable by category (not interchangeable 1:1) | Confirmed in authorised distribution: same polymer and rapid absorption profile (≈42 days, 50% retention at 5 days), USP 2/0 gauge, colourless colour and 70 cm length match. The needle point family differs: conical SH-1 Plus needle versus the reverse-cutting triangular point with square body of this reference. Not interchangeable 1:1; validate technical data sheet/IFU before substituting. |
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (rapid multifilament PGAR, XDS24 24 mm precision reverse-cutting needle with square body, USP 2/0 gauge, colourless 70 cm thread, ref. P228XDS2420) with references from other manufacturers in the exact configuration; consult the technical department before using in a tender. The cited homologous families (VICRYL RAPIDE® and VICRYL® from Ethicon, Safil Quick from B. Braun and rapid PGA lines from DemeTECH, SMI and Dolphin Sutures) must be reviewed property by property (material, gauge, curvature, needle point family, length, number of strands, colour, coating and current CE/MDR regulatory classification) before any substitution. The code W9915 (VICRYL RAPIDE®) appears in Ethicon’s official catalogue, but its gauge and needle configuration appears contradictory in distribution sources, so the packaging must be verified before cross-referencing it; the factory reference for this article does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before use in tender documents. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
Tissue to suture: USP 2/0 gauge (metric EP 3) with a 24 mm needle is the balance point between fineness and strength for approximation of dense subcutaneous tissue, skin closure and ligation of medium-calibre vessels. The precision reverse-cutting point with square body penetrates firm tissues without tearing the puncture bed, making it especially suitable for plastic and cosmetic surgery: better aesthetic outcome and less trauma. Do not use in tissues requiring prolonged support (fascia, abdominal wall under tension), given its rapid absorption profile.
Variants within the rapid PGAR range: if you prefer the standard DS24 needle profile with 75 cm thread, you have AM222DS2420 (standard quality) and AMP222DS2420 (Prime quality with grooved needle); for approaches with ½ circle curvature and conical point, references AMP222HR2220 (22 mm) and AMP222HR4020 (40 mm) in USP 2/0 cover other scenarios (soft tissues, mucosa, peritoneum). All are supplied in a box of 12 units.
Alternative absorption profile: if the procedure requires longer wound support, consider standard polyglactin 910 or PGA (56–90 days), PGCL monofilament (90–120 days) or polydioxanone PDO (180–210 days), depending on the patient’s healing kinetics.
Sterility verification: sterile product by gamma radiation and single-use; check the blister integrity and expiry date before each procedure, keep the reference P228XDS2420 and the batch number for traceability in the operating theatre, and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.