1. Commercial Introduction
The absorbable multifilament suture PREMISUT RAPID in Prime quality is the reference surgical closure solution when the procedure requires short-term wound support, fully predictable absorption and excellent tissue handling. This configuration combines a braided strand of 100% high-purity polyglactic acid in USP 5/0 gauge, undyed and 75 cm, with a ⅜ circle reverse cutting triangular point needle of 16 mm (DS16 profile): the ideal combination for soft tissue approximation, small-calibre vascular ligation, superficial layer closure and general surgery with minimal tissue reaction.
Designed for continuous supply to operating theatres, general surgery departments, minor ambulatory surgery, clinics and B2B purchasing centres, it is presented in a box of 12 units with individual sterile pouches and batch traceability. An excellent value for money for hospital replenishment and tenders.
2. Technical Explanation
Rapid profile polyglactic acid (PGAR) is a 100% synthetic polymer absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissue, improves thread glide and facilitates firm, secure knotting, with minimal tissue reaction.
In its rapid absorption variant (RAPID, low molecular weight), degradation occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— over a period of 40 to 45 days, with retention of 50% of the initial tensile strength at 5 days and total loss of tensile support at 14 days: it is indicated when only short-term wound support is required and residual foreign material is to be minimised.
The DS16 needle features a ⅜ circle (135°) curvature with a triangular body and reverse cutting point: the cutting edge is on the outer curve, allowing it to penetrate firm, inelastic tissues —skin, mucosa, subcutaneous tissue— with less resistance and without enlarging the exit hole. Its 16 mm length and reduced radius make it especially manageable in small surgical fields and precision sutures. The undyed thread (uncoloured) provides maximum discretion in the surgical bed and aesthetic advantages in superficial areas. Sterilisation by gamma radiation; single-use product, not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet of the reference
| Factory reference | P222DS1650 (Prime range) |
| Reference Cahnos (SKU) | AMP222DS1650 (box of 12 units) |
| Brand / quality | PREMISUT RAPID (Prime range) |
| Thread material | 100% polyglactic acid (PGAR), synthetic absorbable, low molecular weight variant (RAPID) |
| Thread structure | Coated braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 5/0 (metric 1 / EP 1), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.10 – 0.149 mm |
| Thread colour | Colourless (undyed) |
| Thread length | 75 cm (free end, without loop) |
| Needle shape | ⅜ circle (3/8 circular, 135°) |
| Needle body | Triangular |
| Needle tip | Reverse cutting |
| Needle size | 16 mm (DS 16 Prime), 1 needle per thread |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis; complete between 40 and 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets); minimum order 30 boxes |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR) |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglycolic acid (PGA line, 60–90 days) nor with standard polyglactin 910 (56–72 days).
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 6/0 | 0.7 | 0.07 – 0.099 mm |
| 5/0 (this product) | 1 | 0.10 – 0.149 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding its limits.
4. Equivalences and Cross-References
Rapid absorption polyglactic acid (PGAR) belongs to the worldwide family of short-term braided absorbable sutures of the PGA/polyglactin rapid profile type, whose international clinical reference is the VICRYL RAPIDE line (Ethicon / Johnson \u0026 Johnson MedTech), with an absorption profile ≈ 42 days and early tensile strength retention. The following match is a functional comparison at category level and should not be treated as a 1:1 interchangeable without prior technical validation:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | VR2296 – USP 5/0, 16 mm ⅜ circle reverse cutting needle, undyed thread 75 cm, box of 36 units | Comparable by category (not interchangeable 1:1) | They match in rapid absorption profile (≈ 42 days), USP 5/0 gauge, braided multifilament structure, undyed thread 75 cm, ⅜ circle curvature and 16 mm needle with reverse cutting point; they differ in polymer (polyglactin 910 —90% glycolide / 10% L-lactide— versus polyglactic acid), braid coating and packaging format (36 units in Ethicon versus 12 units). Code verified in authorised distribution and manufacturer catalogues; check IFU before substituting. |
The remaining homologous lines in the rapid absorption segment (Safil Quick and Novosyn Quick from B. Braun / Aesculap, DemeCRYL Fast from DemeTECH and Surgicryl Fast Absorb from SMI) must be reviewed property by property —material, USP 5/0 gauge, multifilament structure, ⅜ circle curvature, reverse cutting point family, needle length 16 mm, strand 75 cm, undyed colour, 1-needle configuration and CE/MDR regulatory classification— before any substitution; unverified cross-reference codes are not published. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other gauges, needle geometries and lengths (see block 5), which are fully interchangeable with each other respecting gauge and needle geometry.
5. Selection tips and variants of interest
USP 5/0 (metric 1) is a fine size indicated for low-tension tissues: skin and mucosa approximation, subcutaneous tissue, superficial planes and ligation of small-calibre vessels in general and minor surgery. The DS16 needle, ⅜ circle with reverse cutting point, offers precise penetration in firm tissues without enlarging the exit orifice: the recommended option for precision sutures in fields with limited access. The undyed version ensures maximum discretion in the surgical bed.
| Variant (SKU) | Description |
| AMP222DS1650 (P222DS1650) | PGAR RAPID Prime – DS16 reverse cutting – USP 5/0 undyed – 75 cm (this product) |
| AMP222DS1950 (P222DS1950) | PGAR RAPID Prime – DS19 reverse cutting – USP 5/0 undyed – 75 cm (same strand, 19 mm needle for slightly wider fields) |
| AMP222DS1250 (P222DS1250) | PGAR RAPID Prime – DS12 reverse cutting – USP 5/0 undyed – 75 cm (same strand, 12 mm needle for smaller sutures) |
| AMP222HR1750 (P222HR1750) | PGAR RAPID Prime – HR17 taper point – USP 5/0 undyed – 75 cm (taper point, atraumatic passage in lax tissues) |
| AM222HR1750 (222HR1750) | PGAR RAPID standard – HR17 taper point – USP 5/0 undyed – 75 cm (standard range, same geometry and size) |
If the protocol prefers atraumatic penetration in lax tissues, consider the taper point series (HR taperpoint) from the same range; if a larger working field is required, consult DS19 needles or ½ circle series. For planes with moderate tension, consider larger sizes (USP 4/0 or 3/0) within the same PGAR RAPID family. If greater thread visibility is required, consult the same configuration in a dyed version on request.
Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each procedure and keep the reference together with the batch number for traceability in the operating theatre. Store below 30 °C, in a cool, dry place, protected from direct sunlight. For special B2B conditions, volume orders or enquiries about additional sizes, lengths and colours, contact the technical-commercial team at Cahnos.