We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGAR RAPID (PREMISUT RAPID) · Needle ½ Circle Cylindrical Conical Point Taperpoint 26 mm (HR26) · USP 3/0 (Metric 2) Undyed · Thread 75 cm · Ref. 222HR2630 · Box 12 units

Original price was: 34,90 €.Current price is: 29,20 €.

Absorbable multifilament suture PGAR RAPID (rapid absorption polyglycolic acid) from the PREMISUT RAPID range, in USP 3/0 gauge (metric 2), undyed thread of 75 cm and a ½ circle needle with cylindrical body and conical Taperpoint point of 26 mm (HR26): atraumatic passage ideal for soft tissues. Predictable absorption by hydrolysis in 40–45 days, with 50 % of tensile strength at day 5 and total loss at day 14. Sterile by gamma radiation, single-use and with minimal tissue reaction. Factory ref. 222HR2630 · SKU AM222HR2630 · Box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM222HR2630

Description

1. Commercial Introduction

The multifilament absorbable suture PREMISUT RAPID from the PGAR range (rapid-profile polyglycolic acid) is the reference for accelerated absorption for the professional who needs a braided thread with predictable handling, secure knotting and complete disappearance from the body within a few weeks, without the need to remove stitches. This configuration combines a 100% polyglycolic acid strand in USP 3/0 gauge, colourless and 75 cm long, with a ½-circle needle with cylindrical body and Taperpoint conical point of 26 mm (HR26): atraumatic penetration, ideal for approximating soft tissues, ligatures and general surgery.

Sterile, ready-to-use product, supplied in a box of 12 units in individual sachets with batch traceability. Aimed at hospital replenishment, purchasing centres, clinics and B2B tenders looking for a fast-absorbing thread with an excellent price-quality ratio.

2. Technical Explanation

The PGAR suture (rapid-profile polyglycolic acid) is a 100% absorbable synthetic polymer by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread glide and facilitates firm, secure knotting, with minimal tissue reaction and excellent initial tensile strength.

Its degradation profile is designed for short-term healing: it retains 50% of tensile strength at 5 days and loses virtually all its resistance at 14 days, completing absorption by hydrolysis between 40 and 45 days. The HR26 needle features a ½-circle curvature (160°) with a cylindrical body and Taperpoint conical point: the round body allows clean passage through soft tissues and the conical point separates fibres without an aggressive cutting effect, minimising trauma to the puncture bed. USP 3/0 gauge (metric 2) is the reference size for tissues under moderate tension and rapid healing. Sterilised by gamma radiation; single-use product, not re-sterilisable.

3. Technical Specifications

3.1. Technical data sheet of the reference

Parameter Specification
Factory reference 222HR2630 (PREMISUT RAPID nomenclature)
Reference Cahnos (SKU) AM222HR2630
Brand / quality PREMISUT RAPID (standard range)
Thread material 100 % polyglycolic acid (PGAR), braided multifilament
Coating Polycaprolactone and calcium stearate
Gauge / size USP 3/0 (metric 2 / EP 2), conforming to USP/EP Pharmacopoeia
Approximate thread diameter 0.20 – 0.249 mm
Thread length 75 cm (free end, without loop)
Thread colour Colourless
Needle shape ½ circle (1/2 circular, 160°), cylindrical body
Needle tip Conical / Taperpoint (atraumatic)
Needle size HR 26 (26 mm), 1 needle per suture
Swaged 1 needle / 1 suture per unit
Absorption By hydrolysis, completed between 40 and 45 days
Tensile strength retention 50% at 5 days; 0% at 14 days
Sterilisation Gamma radiation; sterile, single-use, not re-sterilisable
Indications Approximation of soft tissues, ligatures and general surgery
Commercial presentation Box of 12 units (individual sterile sachets)
Regulatory standard Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR)

3.2. Absorption profile and tensile strength retention

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Complete absorption 40 – 45 days by hydrolysis (predictable and uniform rate)

The cited retention profile corresponds to the rapid-absorption formulation (RAPID line); it should not be confused with standard-absorption polyglycolic acid (60–90 days) or standard polyglactin 910 (56–72 days), also available in our catalogue.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
3/0 (this product) 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm
0 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm

The strand diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding their limits.

3.4. Decoding of the official reference

The official reference 222HR2630 decodes as: 222 (75 cm thread) + HR26 (½-circle needle, cylindrical body, 26 mm Taperpoint conical point) + 30 (USP 3/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.

4. Equivalences and Cross-References

Reference 222HR2630 corresponds to the official nomenclature of the PREMISUT RAPID range (rapid-absorption polyglycolic acid, multifilament, USP 3/0, colourless 75 cm thread, ½-circle cylindrical needle with 26 mm Taperpoint conical point). Rapid-absorption polyglycolic acid (PGAR) is one of the most widespread short-term braided absorbable suture families on the market and is comparable at clinical category level with the rapid lines of major manufacturers. The following reference from another manufacturer has been checked against the official catalogue and authorised distribution:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) Novosyn Quick colourless C3046041 (DDP) / G3046041 (box of 12 units) Comparable by category (not interchangeable 1:1) Same configuration verified in the official B. Braun catalogue: ½-circle round-body needle of 26 mm, USP 3/0 (EP 2), colourless 75 cm thread, coated braided. Difference: polyglactin 910 polymer (PGLA 90/10) versus polyglycolic acid; same rapid-absorption profile (~40 days).

As homologous families in the same clinical segment (rapid-absorption multifilament synthetic absorbable sutures with ½-circle cylindrical needle), mention may be made of Vicryl Rapide (Ethicon, low-molecular-weight polyglactin 910) and Safil Quick (B. Braun), whose specific references for 3/0 with 26 mm conical needle could not be verified in an official source in this review; they must be confirmed against the manufacturer’s technical data sheet before use. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. The brands cited belong to their respective manufacturers and are mentioned solely for comparative reference.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other provided the gauge and needle geometry are respected.

5. Selection tips and variants of interest

USP 3/0 gauge (metric 2) is a fine-to-medium size indicated for approximating soft tissues under moderate tension: skin, subcutaneous tissue, mucosa, episiotomies, phimosis, ligatures of small-calibre vessels, general surgery and minor surgery. The HR26 ½-circle needle with Taperpoint conical point passes through soft tissues separating fibres without a cutting effect: it is the recommended option for lax, well-perfused tissues, where an atraumatic passage and minimal bleeding are sought. If the tissue is denser, consider the same family with Tapercut trocar point (HRT26). The colourless colour offers maximum discretion in the surgical field and is preferred in aesthetic areas or superficial tissue.

Variant (SKU) Description
AMP222HR2630 (P222HR2630) PGAR RAPID Prime – HR26 conical point – USP 3/0 colourless – 75 cm (same configuration, Prime quality; direct equivalent within the same manufacturer)
AM222HR2620 (222HR2620) PGAR RAPID – HR26 conical point – USP 2/0 colourless – 75 cm (larger gauge, same needle)
AM222HR2610 (222HR2610) PGAR RAPID – HR26 conical point – USP 0 colourless – 75 cm (larger gauge, same needle)
AM228HR2640 (228HR2640) PGAR RAPID – HR26 conical point – USP 4/0 colourless – 70 cm (fine gauge for delicate planes)
AM222HRT2620 (222HRT2620) PGAR RAPID – HRT26 trocar point – USP 2/0 colourless – 75 cm (trocar point for firmer tissues)
AM222HR3020 (222HR3020) PGAR RAPID – HR30 conical point – USP 2/0 colourless – 75 cm (longer needle, larger field)

Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and retain the reference 222HR2630 along with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer reference

222HR2630

Material

100% polyglycolic acid (PGAR) braided multifilament

Coating

Polycaprolactone and calcium stearate

Gauge

USP 3/0 (metric 2 / EP 2)

Thread diameter

0.20 – 0.249 mm

Needle shape

½ circle (160°), cylindrical body

Needle tip

Conical / Taperpoint

Needle size

26 mm (HR26)

Swaged

1 needle / 1 suture

Sterilisation

Gamma radiation

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units

Indications

Approximation of soft tissues, ligation, general surgery

Regulatory standard

USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HR 26

Usp

3/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGAR RAPID (PREMISUT RAPID) · Needle ½ Circle Cylindrical Conical Point Taperpoint 26 mm (HR26) · USP 3/0 (Metric 2) Undyed · Thread 75 cm · Ref. 222HR2630 · Box 12 units”

Your email address will not be published. Required fields are marked *