Description
1. About this suture
The absorbable multifilament PGA suture without needle from the PREMISUT line, in USP 3/0 gauge and presentation of 6 threads of 45 cm in violet colour, is the reference solution for B2B supply to operating theatres, purchasing centres, minor surgery clinics and healthcare distributors. As it has no mounted needle, the surgeon can thread the strand onto the needle holder or ligature needle of their choice, which optimises stock and provides maximum assembly flexibility. Synthetic absorbable medical device, sterile, single-use and with an excellent quality-price ratio for the continuous supply of your centre. Ref. 11-6.4530 · SKU AM11-6.4530.
2. Technical explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer with a long clinical track record that is presented in a braided multifilament structure, coated with polycaprolactone and calcium stearate. This coating reduces friction with tissue, minimises the saw effect during passage and promotes smooth sliding, while maintaining excellent knot security. Absorption occurs by hydrolysis (chemical degradation in contact with tissue fluids, independent of the patient’s enzymatic activity), which ensures very predictable reabsorption in 60-90 days and minimal tissue reaction. The USP 3/0 gauge (metric EP 2) maintains the necessary tensile support during the critical phase of healing: 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. The violet colour ensures immediate visual identification on the surgical field, and ethylene oxide (EO) sterilisation confirms the condition of sterile single-use product, not resterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Composition | 100% polyglycolic acid (PGA), synthetic absorbable |
| Thread structure | Braided and coated multifilament |
| Coating | Polycaprolactone and calcium stearate |
| USP / metric gauge | USP 3/0 (metric equivalent EP 2) |
| Thread colour | Violet |
| Length / presentation | 6 threads of 45 cm each, without needle |
| Absorption mechanism | Hydrolysis, complete absorption in 60-90 days |
| Tensile strength retention | 75% (2 weeks) · 50% (3 weeks) · 40% (4 weeks) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 30 boxes |
| References | 11-6.4530 · SKU AM11-6.4530 |
| Regulatory standard | USP / European Pharmacopoeia (EP) |
4. Equivalences and Cross-References
The technical profile of this thread (coated braided multifilament PGA, violet, without needle, absorption 60-90 days, use in ligatures and tissue approximation) corresponds to the category of synthetic absorbable polyglycolic acid sutures available on the European market. The following homologous reference has been verified against manufacturer and authorised distribution sources:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| SMI (Belgium) | Surgicryl® PGA without needle | 11200015 (manufacturer ref.) / EAN 5404020001644 | Comparable by category (not interchangeable 1:1) | Same principle: braided multifilament PGA coated with polycaprolactone and calcium stearate, violet, without needle, absorption 60-90 days. They differ in presentation (SMI offers formats 3×50 cm, 5×70 cm and 150 cm versus 6×45 cm) and the declared retention profile (approx. 50% at 21 days). Verified in authorised distributor catalogue with manufacturer data. |
Furthermore, other homologous families in the same category on the market are Safil® (B. Braun), Dexon / Dexon S (Medtronic), DemeSORB® PGA (DemeTECH) and AssuCryl® (Assut Medical), whose specific codes for the needle-free format must be confirmed with the manufacturer before any substitution. The VICRYL™ (Ethicon) and Novosyn® (B. Braun) ranges use poliglactin 910 (PGLA) copolymer, chemically different from PGA homopolymer and with an absorption profile of 56-72 days, so they are not interchangeable 1:1 without technical validation. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
The USP 3/0 gauge is the usual choice for ligatures of small and medium-calibre vessels, subcutaneous tissue, approximation of superficial planes and minor surgery. As it is a needle-free format, verify compatibility with the needle holder and the assembly technique of your centre, and it can be freely combined with reusable ligature needles according to the surgeon’s preference. If your protocol requires a finer gauge for delicate tissues, the same family offers the PGA variant without needle USP 4/0 and 5/0 in 6×45 cm (SKU AM11-6.4540 and AM11-6.4550); for larger gauges, the USP 2/0, 0, 1 and 2 variants in 6×45 cm (SKU AM11-6.4520, AM11-6.4510, AM11-6.4501 and AM11-6.4502). It also offers presentations of 10×60 cm (e.g. AM11-10.6030 for 3/0) and formats of 2×70 cm, 12×45 cm, 150 cm and 180 cm on demand. Sterile single-use product: check the integrity of the pouch and the expiry date before each procedure, keep the reference together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight. For hospital supply contracts or consultation of additional gauges, lengths and colours (colourless thread available), contact the technical-commercial team at Cahnos.