Description
1. Product Presentation
At Cahnos we offer this absorbable multifilament polyglycolic acid (PGA) suture, reference AM128GS6030 (PREMISUT price list 128GS6030), a professional solution for B2B supply to operating theatres, purchasing centres and general surgery services. The presentation includes a straight needle with triangular point and conventional cutting edge of 60 mm (GS60 model), undyed 70 cm thread in USP 3/0 gauge and reliable knot-holding capacity, ideal conditions for tissue approximation, ligatures and sutures with direct access to the surgical field. Predictable behaviour, excellent initial tensile strength, minimal tissue reaction and special hospital supply conditions for volume contracts.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure coated with polycaprolactone and calcium stearate, which gives it a smooth, non-grooved surface that slides gently through tissue, minimising the sawing effect and tissue reaction. Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the thread maintains mechanical tissue support during the critical healing phase (75% of strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks) and is reabsorbed progressively and controllably between 60 and 90 days.
The straight GS model 60 mm needle, with a triangular conventional cutting point, facilitates penetration into resistant, low-elasticity tissues, allowing manual suturing on accessible surfaces with absolute control of the needle path. It is especially useful for approximation stitches, superficial continuous sutures and direct-access ligatures. The undyed colour of the strand favours aesthetic discretion without interfering with visualisation of the surgical field. The product is supplied sterile by ethylene oxide (EO), is single-use and cannot be re-sterilised.
3. Technical Specifications
| Parameter | Specification |
| Reference (SKU Cahnos) | AM128GS6030 |
| Tariff reference (PREMISUT) | 128GS6030 |
| Brand / Quality | PREMISUT – standard quality |
| Material | 100 % synthetic absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament, non-grooved surface |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / USP size | USP 3/0 (metric 2) |
| Thread length | 70 cm |
| Needle shape | Straight |
| Tip type | Triangular – conventional cutting |
| Needle size | 60 mm (GS60 model) |
| Thread colour | Undyed (also available violet depending on presentation) |
| Absorption | By hydrolysis, between 60 and 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (minimum order of 30 boxes) |
Tensile strength retention profile:
| Time point | Strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Total absorption | 60 – 90 days |
Gauge equivalence:
| USP size | Metric size | Approximate diameter |
| 3/0 | 2 | 0.20 – 0.249 mm (indicative according to USP Pharmacopeia) |
4. Equivalences and Cross-References
Braided and coated multifilament polyglycolic acid (PGA) is the most widely used medium-duration synthetic absorbable on the market, and the 60 mm triangular straight needle configuration (GS60) in USP 3/0 gauge is one of the most in demand for manual suturing. The homologous commercial reference ranges are the ASSUFIL®/AssuCryl® line from Assut Europe (braided and coated PGA, 60-90 day absorption), the P.G.A. line from Laboratorio Aragó with TR-60 triangular straight needle, as well as PGA series from manufacturers such as WEGO, Dolphin Sutures, CP Medical and SMI (Surgicryl®). In the polyglactin 910 (PGLA) segment, a material from the same clinical family but of different composition (copolymer of glycolide and L-lactide), are the Vicryl® (Ethicon), Safil® (B. Braun) and Polysorb™ (Medtronic) ranges.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The analogous geometry references verified in public sources (e.g. P.G.A. TR-60 from Laboratorio Aragó, code 4301712, or ASSUFIL® FU56436 from Assut Europe in GS60 triangular straight needle) correspond to USP 2/0 gauge, different from that of this product (USP 3/0), and therefore cannot be listed as 1:1 interchangeable. The matches identified should be treated as functional category comparisons and not as direct equivalents without technical validation; consult the Cahnos technical department before using this information in tenders or in the direct substitution of references. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: 3/0 is suitable for skin, subcutaneous tissue and approximation of soft tissues under moderate tension; 2/0 for tissues with greater mechanical demands and ligatures; and 4/0 for fine tissues and precision surgery. The straight conventional cutting needle is ideal for approximation sutures and ligatures with direct access to the surgical field.
Variants of interest within the Cahnos catalogue in the same GS60 format:
- AMP128GS6030: PGA Prime, GS60 straight needle, USP 3/0, undyed, 70 cm (same configuration with Prime quality, improved surface).
- AM128GS6020 / AM128GS6040: PGA standard quality, GS60 straight needle, USP 2/0 and 4/0, undyed, 70 cm (alternative gauges from the same line).
- AM112GS6030: PGA, GS60 straight needle, USP 3/0, violet, 75 cm (greater strand visibility over the field).
- P1L28GS6030: PGLA (polyglactin 910) Prime, GS60 straight needle, USP 3/0, undyed, 70 cm (same needle geometry; copolymer material with 56-72 day absorption).
- AM328GS6030: PGCL (poliglecaprone 25) monofilament, GS60 straight needle, USP 3/0, undyed, 70 cm (90-120 day absorption, when the protocol requires longer support duration).
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply agreements or enquiries about equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.