1. Commercial Introduction
At Cahnos we offer the absorbable multifilament polyglycolic acid (PGA) suture in Prime quality, reference AMP118GS4830, a high-end professional solution for the B2B supply of operating theatres, clinics and purchasing centres. This presentation combines a straight needle with triangular point and conventional cutting of 48 mm (GS48), USP 3/0 gauge and a colourless 70 cm thread with a soft feel and controlled passage through tissue.
It is the ideal choice for tissue approximation procedures, ligatures and general surgery where predictable absorption, reliable mechanical support during the first weeks of healing and the convenience of not having to remove the thread are required. It is supplied sterile, ready for immediate use in the operating theatre, in a box of 12 units with special B2B ordering conditions.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer, structured as a braided multifilament with a coating of polycaprolactone and calcium stearate, which ensures smooth passage through tissue, low memory and a firm, secure knot seating, even in fine gauges such as USP 3/0 (metric 2).
Its absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable interval of 60 to 90 days. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing (75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks), while the tissue recovers its own resistance.
The straight needle with triangular point and conventional cutting of 48 mm penetrates firm tissues with absolute control of the path, being especially suitable for manual suturing on directly accessible surfaces. The colourless thread provides discretion in visible areas and does not interfere with visualisation of the surgical field. The product is supplied sterile by ethylene oxide (EO), is single-use and cannot be re-sterilised; tissue reaction is minimal and the absorption rate is totally predictable.
3. Technical Specifications
3.1. Technical data sheet for reference AMP118GS4830
| Reference (SKU) | AMP118GS4830 |
| Quality | Prime |
| Material | 100% Polyglycolic acid (PGA), absorbable by hydrolysis |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, non-grooved surface |
| Gauge | USP 3/0 (metric 2) |
| Thread length | 70 cm |
| Thread colour | Colourless |
| Needle shape | Straight |
| Tip type | Triangular – Conventional cutting (Conventional Cutting) |
| Needle size | GS48 (48 mm) |
| Absorption mechanism | By hydrolysis, between 60 and 90 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention and absorption profile
| Period | Tensile strength retention |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 3/0 | 2 | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
Excellent tensile strength and knot tying capability, with a totally predictable absorption rate that allows tissue support to be planned with great reliability. Price per box of 12 units.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
From a clinical point of view, this multifilament polyglycolic acid (PGA) suture, straight conventional cutting needle GS48, USP 3/0 gauge and colourless 70 cm thread, falls into the same functional category as the most widely used synthetic absorbable braided sutures of medium absorption on the international market, among which the families Vicryl/Vicryl Plus (Ethicon – Johnson & Johnson), Safil (B. Braun), Polysorb (Medtronic / Covidien), Surgicryl (SMI), Assucryl 910 (Assut Sutures) and Vitacryl (DemeTECH) stand out, as well as the polyglycolic acid lines marketed by different suture suppliers. These brands belong to their respective manufacturers and are mentioned only as an indicative category reference: they differ in exact composition (PGA homopolymer versus polyglactin 910 copolymer), absorption profile (60-90 days versus 56-72 days) and internal needle nomenclature, so they are not interchangeable 1:1 without prior verification of the technical data sheet.
Within the Cahnos catalogue, the reference with the same needle geometry (GS48, conventional cutting, USP 3/0, colourless, 70 cm, non-channeled) in polyglactin 910 (PGLA) is P1L28GS4830 (absorption 56-72 days). For a formal substitution of references in contracts, consult our technical-commercial department.
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: USP 3/0 (metric 2) is a versatile size, indicated for skin, subcutaneous tissue, mucosa, fascia and tissues with moderate tension in general surgery and ligatures. The straight conventional cutting needle of 48 mm (GS48) is especially suitable for manual suturing on directly accessible surfaces, where firm penetration into tissues of medium or high consistency with control of the path is required.
Variants of interest in the Cahnos catalogue: AMP118GS2530 (PGA Prime, straight needle GS25, USP 3/0, violet, 70 cm) for a shorter needle; AMP118GR4830 (PGA Prime, straight needle GR48 with conical point, USP 3/0, violet, 70 cm) for delicate tissues where atraumatic penetration is prioritised; P1L28RGS4830.2 (PGLA Prime, GS48, USP 3/0, colourless, 2 x 70 cm) in double strand presentation; and AMP2L22GS4830 (PGLA Rapid, GS48, USP 3/0, colourless, 75 cm) when faster absorption is required (40-45 days).
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact our technical-commercial team.