We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture (Polyglycolic Acid) | ⅝ Circle Cylindrical Taperpoint Conical Point Needle FR 40 mm | USP 0 Gauge (Metric 3.5) | Violet Fluted Thread 70 cm | Ref. 118FR4010 – Box of 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable multifilament polyglycolic acid (PGA) suture from the PREMISUT range, reference 118FR4010 (SKU AM118FR4010). It features a ⅝ circle needle with a cylindrical body and a 40 mm Taperpoint conical point (FR 40), USP 0 gauge (metric 3.5), and a 70 cm fluted violet braided thread coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis between 60 and 90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterilised by ethylene oxide, single-use, with minimal tissue reaction and optimal knot security. Indicated for tissue approximation, ligation and general surgery. Presentation in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM118FR4010

Description

1. Commercial Introduction

The absorbable multifilament polyglycolic acid (PGA) suture from the PREMISUT range, reference 118FR4010 (SKU AM118FR4010), is the reference surgical closure solution for the professional seeking a braided, flexible thread with fully predictable absorption in the operating theatre. Its ⅝ circle needle with cylindrical body and 40 mm Taperpoint conical point separates tissue fibres without cutting them, minimising trauma, and its 70 cm violet grooved thread ensures optimal visibility on the surgical field. It is a synthetic absorbable medical device, sterile and single-use, with an excellent quality-price ratio for B2B procurement in hospitals, clinics, private operating theatres and purchasing groups. It is supplied in a box of 12 units with a minimum order of 30 boxes, ensuring continuous and traceable supply for your healthcare facility.

2. Technical Explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, low memory and firm, secure knot tying, with high initial tensile strength.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days. This profile makes the suture ideal for tissues requiring wound support during the critical 2 to 4 weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ⅝ circle needle with Taperpoint conical point penetrates by separating the fibres without cutting them, being especially recommended for soft and friable tissues. The product is supplied sterile by ethylene oxide (EO), single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference 118FR4010

Reference (SKU) 118FR4010 (AM118FR4010)
Range / Quality PREMISUT – Normal quality
Material 100 % polyglycolic acid (PGA), homopolymer of glycolic acid
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 0 (metric 3.5)
Thread colour Violet (colourless version available in the family)
Thread length 70 cm
Needle shape ⅝ circle
Needle body Cylindrical
Needle tip Taperpoint conical
Needle size 40 mm (FR 40)
Absorption mechanism Hydrolysis
Absorption period 60-90 days
Sterilisation Ethylene oxide (EO); single-use, non-reesterilizable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units
Minimum order 30 boxes

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
3 weeks 50 %
4 weeks 40 %
Total absorption 60-90 days (by hydrolysis)

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

3.3. Presentation and ordering conditions

Presentation Box of 12 units
Minimum order 30 boxes
Format Sterile, single-use

4. Equivalences and Cross-References

Pure polyglycolic acid (PGA) is one of the most widely used braided synthetic absorbable materials on the market. This reference is comparable by category, composition, absorption profile and tensile retention with the coated multifilament sutures of the main manufacturers:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Medtronic / Covidien Dexon® II (coated braided PGA, violet colour) 9843-61 Comparable by category (not interchangeable 1:1) Same material (PGA homopolymer) and coated braided structure; USP 0 gauge (metric 3.5) and violet colour. The needle differs: ⅝ circle with GU-45 taper point, 37 mm versus 40 mm, and thread length 75 cm versus 70 cm; slightly lower retention profile in the manufacturer’s official catalogue.
Ethicon (Johnson & Johnson) Coated VICRYL® (braided polyglactin 910, violet colour) J381H Comparable by category (not interchangeable 1:1) Same needle assembly (⅝ circle UR-4 taper point, 40 mm), USP 0 gauge and 70 cm violet thread. Different material: polyglactin 910 (copolymer), not pure PGA, with approximate absorption of 56-70 days. Code consistently verified with authorised distributors; confirm with the manufacturer before use in tenders.

The above equivalences are functional category comparisons verified against sources from the cited manufacturers themselves and do not constitute an official cross-reference table. The Safil® line from B. Braun (same polymer and violet presentation) also falls within the same family of braided pure PGA; its exact reference must be checked with the manufacturer. There is no equivalence table validated by the manufacturer of this reference; consult the technical department at Cahnos before use in tenders.

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the gauge needed according to the anatomical area. USP 0 gauge (metric 3.5) is highly versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues and ligatures in general surgery, with an excellent balance between initial strength and predictable absorption during a healing period of 2 to 4 weeks. The ⅝ circle needle with Taperpoint conical point is especially recommended for delicate tissues where atraumatic penetration is prioritised; for fibrous or dense structures, cutting or trocar points (HS or HRT series) are recommended.

Reference Variant
AM118FR4010 PGA USP 0, 5/8 cylindrical needle FR 40 mm, violet, 70 cm (current product)
AMP118FR4010 PGA Prime USP 0, same 70 cm configuration (premium range)
AM118FR4020 PGA USP 2/0, same FR 40 mm needle, violet, 70 cm (smaller gauge)
1L18FR4010 PGLA (polyglactin 910) USP 0, same FR 40 mm needle, violet, 70 cm (absorption 56 to 72 days)
AM118FR3610 PGA USP 0, FR 36 mm needle, violet, 70 cm (smaller needle radius)
AM118HR4010 PGA USP 0, ½ circle HR 40 mm needle, violet, 70 cm (different needle curve)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. If you require longer strength retention (180-210 days), the polydioxanone (PDO) family is the recommended alternative. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or equivalents from other manufacturers, contact our technical-commercial team.

Additional information

Material

100% Polyglycolic Acid (PGA)

Structure

Braided multifilament with grooved finish

Coating

Polycaprolactone and calcium stearate

Gauge

USP 0 (metric 3.5)

Needle body

Cylindrical

Needle tip

Taperpoint conical

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

118FR4010

Medida de aguja

FR 40

Usp

0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

5/8 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture (Polyglycolic Acid) | ⅝ Circle Cylindrical Taperpoint Conical Point Needle FR 40 mm | USP 0 Gauge (Metric 3.5) | Violet Fluted Thread 70 cm | Ref. 118FR4010 – Box of 12 units”

Your email address will not be published. Required fields are marked *