Description
1. Commercial presentation
At Cahnos we offer you the absorbable multifilament suture of polyglycolic acid (PGA) from the Prime range, reference P118FR2710 (SKU AMP118FR2710), designed for the professional who demands reliable, manageable and predictable performance in the operating theatre. This presentation combines a 5/8 circle needle with cylindrical body and Taperpoint conical point of 27 mm (FR 27), USP 0 gauge (metric 3.5) and a 70 cm violet braided grooved thread: maximum visibility on the surgical field and precision in delicate tissues.
It is the reference choice for hospitals, private clinics, ophthalmologists and purchasing centres looking for a high-performance synthetic reabsorbable suture with an excellent price-quality ratio. It is supplied in a box of 12 units, sterile by ethylene oxide and ready for immediate use, with the warranty of professional distribution from Cahnos.
2. Technical Explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer of fully synthetic origin, structured as a braided multifilament with a grooved finish. This configuration provides great flexibility, low memory and a low friction coefficient, which favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying. The coating of polycaprolactone and calcium stearate reduces friction and improves the fluidity of passage through tissue.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, maintaining apposition of the edges during the critical 2 to 4 weeks of healing. The 5/8 circle needle with cylindrical body and Taperpoint conical point penetrates by separating the fibres without a cutting effect, minimising trauma to delicate structures; it is therefore especially recommended for approximation of friable tissues, ligatures and general surgery. The violet colour guarantees optimal visibility of the thread on the surgical field. The product is supplied sterile by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference P118FR2710
| Characteristic | Specification |
|---|---|
| Reference (SKU) | P118FR2710 / AMP118FR2710 |
| Brand / Quality | Prime range |
| Material | 100% polyglycolic acid (PGA), absorbable by hydrolysis |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Fluted violet (colourless version available in the family) |
| Thread length | 70 cm |
| Needle shape | ⅝ circle (5/8) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 27 mm (FR 27 Prime) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Complete absorption | 60 – 90 days by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable and controlled absorption rate.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm (indicative according to Pharmacopoeia) |
3.4. Presentation and ordering conditions
| Value | Value |
|---|---|
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
This 100% multifilament polyglycolic acid (PGA) suture belongs to the family of synthetic braided absorbable sutures with medium absorption (60-90 days by hydrolysis). The closest technical cross-reference found in public sources for the exact configuration needle FR 27 / USP 0 gauge / 70 cm / violet is the PGA-RESORBA line:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Resorba (Germany) | PGA-RESORBA | PA1015 (PGA-RESORBA violet, needle FR27, USP 0, 70 cm) | Comparable by category (not interchangeable 1:1) | Same polymer (coated braided PGA), same USP 0 gauge, same FR 27 needle and 70 cm length; they differ in presentation (24 units) and coding system. Code consistently confirmed in distribution catalogues; verify against the official Resorba data sheet before use in tenders. |
By composition and mechanical behaviour, this suture is comparable at category level with the braided polyglactin 910 lines from Ethicon (Vicryl / Vicryl Plus), B. Braun (Novosyn), Medtronic (Polysorb), SMI (Surgicryl), Assut (Assucryl 910) and CPT (CARESORB), as well as with the Safil family from B. Braun in the case of pure PGA. The reference codes from these manufacturers for the exact configuration FR 27 / USP 0 / 70 cm could not be conclusively verified in public sources, so they are not declared here. There is no manufacturer-validated equivalence table for this cross-reference; consult the technical department before use in tenders.
Within the Cahnos catalogue, this reference is directly related to the standard quality version AM118FR2710 (same configuration FR 27 / USP 0 / 70 cm, same PGA family) and to the PGLA Prime family P1L18FR2710, as well as to the variants of the PGA Prime family AMP118FR2701 (USP 1), AMP118FR2720-2 (double needle FR 27 mm), AMP118FR3620 (needle FR 36 mm) and AMP118FR4020 (needle FR 40 mm).
5. Selection tips and variants of interest
USP 0 gauge (metric 3.5) offers an excellent balance between strength and delicacy: it is suitable for subcutaneous tissue, soft tissue, superficial muscle planes, tissue approximation and ligatures, with predictable absorption during healing of 2 to 4 weeks. The 5/8 circle needle with conical point (Taperpoint) of 27 mm is especially recommended in delicate tissues where the cutting effect is to be avoided; for fibrous structures or the sclera, cutting or trocar points are recommended.
| Reference | Variant |
|---|---|
| AMP118FR2710 | PGA Prime USP 0, FR 27 mm needle, violet, 70 cm (current product) |
| AM118FR2710 | PGA standard quality, same configuration FR 27 / USP 0 / 70 cm |
| AMP118FR2701 | PGA Prime USP 1, FR 27 mm needle, violet, 70 cm (larger gauge) |
| AMP118FR2720-2 | PGA Prime USP 2/0, double needle FR 27 mm, violet, 70 cm |
| AMP118FR3620 | PGA Prime USP 2/0, FR 36 mm needle, violet, 70 cm (larger needle radius) |
| AMP118FR4020 | PGA Prime USP 2/0, FR 40 mm needle, violet, 70 cm (larger needle radius) |
| P1L18FR2710 | PGLA Prime USP 0, FR 27 mm needle, violet, 70 cm (absorption 56-72 days) |
Check the needle radius (FR 27, FR 36 or FR 40 mm) according to the depth and surgical area to be treated; for greater tensile strength, consider USP 0 or higher gauges, and if longer force retention (180-210 days) is required, the polydioxanone (PDO) family is the recommended alternative. As a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. All references in the range are supplied in boxes of 12 units with a minimum order of 30 boxes, with scheduled deliveries for hospitals, clinics and purchasing centres. For special B2B conditions by volume or equivalents from other commercial houses, contact our technical-commercial team.





Reviews