We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture (Polyglycolic Acid) | 3/8 Circle Needle Reverse Cutting Triangular Point DS19 (19 mm) | USP 3/0 (Metric 2) | Violet Fluted Thread 75 cm | Ref. 112DS1930 | Box of 12 units

Original price was: 34,90 €.Current price is: 26,90 €.

Absorbable multifilament suture of polyglycolic acid (PGA) from the Premisut range (ref. 112DS1930), mounted on a ⅜ circle needle with a reverse cutting triangular point of 19 mm (DS19) and gauge USP 3/0 (metric 2). Braided violet fluted thread of 75 cm with a coating of polycaprolactone and calcium stearate, which promotes sliding and knot security. Predictable absorption by hydrolysis in 60-90 days, with retention of tensile strength of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterile by ethylene oxide, single-use and with minimal tissue reaction; indicated for tissue approximation, ligatures and general surgery. Presentation in a box of 12 units with special conditions for professional buyers. SKU AM112DS1930.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM112DS1930

Description

1. Commercial Introduction

The absorbable multifilament polyglycolic acid (PGA) suture from the range Premisut, reference 112DS1930, is the trusted choice for the professional seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and general surgery. Its ⅜ circle needle with a 19 mm reverse cutting triangular point (DS19) ensures firm and controlled penetration in tissues of medium consistency, while the 75 cm braided violet grooved thread offers optimal visibility over the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile and single-use, with an excellent value for money for the B2B supply of operating theatres, purchasing centres and surgical material distributors. Commercial presentation in a box of 12 units with a minimum order of 30 boxes.

2. Technical Explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that favours the passage of the thread through the tissue, reduces the sawing effect, offers smooth handling and guarantees firm and secure knot tying in medium working gauges such as USP 3/0 (metric 2, approximate diameter of 0.20 to 0.249 mm according to USP/EP).

Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. The tensile strength retention profile (75 % at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks) maintains the necessary support during the critical phase of healing, while the tissue recovers its own strength.

The ⅜ circle needle with a reverse cutting triangular point (triangular inverted / reverse cutting) of 19 mm penetrates firm and non-compliant tissues (skin, fascia, aponeurosis) with controlled trauma and avoiding tears. The violet colour improves the visibility of the thread over the surgical field. The product is supplied sterile by ethylene oxide (EO), is single-use and is not re-sterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference 112DS1930

Parameter Specification
Brand / Range Premisut (standard quality)
Catalogue reference 112DS1930
SKU Cahnos AM112DS1930
Composition 100% Polyglycolic Acid (PGA) absorbable by hydrolysis
Coating Polycaprolactone and calcium stearate
Thread structure Braided multifilament with grooved finish
Gauge USP 3/0 (metric 2)
Approximate diameter 0.20 – 0.249 mm (indicative according to USP/EP)
Thread colour Violet (also available undyed in the range)
Thread length 75 cm
Needle shape 3/8 circle (approx. 135°)
Tip type Triangular with reverse cutting (inverted triangular / reverse cutting), body and point
Needle size DS19 (19 mm), 1 needle per thread
Absorption mechanism By hydrolysis, between 60 and 90 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Regulatory standard USP / European Pharmacopoeia (EP)
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (minimum order 30 boxes)

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Complete absorption 60-90 days by hydrolysis

Excellent initial tensile strength, optimal knot tying and fully predictable absorption rate, with minimal tissue reaction.

3.3. Size equivalence

USP size Metric size Approximate diameter
3/0 2 0.20 – 0.249 mm (indicative according to USP/EP)

4. Equivalences and Cross-References

Braided coated multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) is one of the most widely used synthetic absorbables in general surgery. The homologous families by composition (PGA homopolymer coated with polycaprolactone and calcium stearate), absorption profile, gauge, needle and colour that have been verified with reference code in public sources are the following. As they are other manufacturers, none is declared interchangeable 1:1 without validation by the technical service.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
SMI (Surgical Materials Industries, Belgium) Surgicryl® PGA (polyglycolic acid, coated braided multifilament) 11201519 (DS19, 19 mm) Comparable by category (not interchangeable 1:1) They match material (pure PGA coated with polycaprolactone and calcium stearate), USP 3/0 gauge (EP 2), violet colour, 75 cm thread and ⅜ circle reverse cutting needle DS19 (19 mm). Configuration confirmed in the official SMI data sheet and authorised distributors; verify needle geometry before replacing. Box of 12 units.
DemeTECH (USA) DemeSORB® PGA (polyglycolic acid, braided coated) PGA283019F4P (DFS-2, 19 mm) Comparable by category (not interchangeable 1:1) They match material (glycolide homopolymer coated with polycaprolactone and calcium stearate), USP 3/0 gauge, violet colour, 75 cm thread (30 inches) and 3/8 circle reverse cutting needle DFS-2 of 19 mm. Configuration confirmed in the official DemeTECH store and authorised distributors; the published retention profile differs (approx. 84 % at 2 weeks / 23 % at 4 weeks). Verify needle geometry before replacing. Box of 12 units.
B. Braun (Aesculap) Safil® (pure polyglycolic acid, braided coated multifilament) C1048421 / G1048421 (DS19) Comparable by category (not interchangeable 1:1) Safil Violet USP 3/0 with 3/8 circle needle DS19 (M) of 19 mm and reverse cutting; the thread length differs (70 cm vs 75 cm) and the coating (polyglyconate vs polycaprolactone). Listed in GUDID/FDA.

There is no equivalence table validated by the manufacturer for this specific configuration (multifilament PGA, ⅜ circle needle DS19 of 19 mm, reverse cutting triangular point, USP 3/0 gauge, violet 75 cm thread); consult the technical department of Cahnos before using in tenders. Before replacing this reference in a specification, check one by one: material, USP gauge, needle size (19 mm), ⅜ curvature, point family (reverse cutting), thread length (75 cm) and colour. Copolymer ranges of polyglactin 910 (PGLA), such as Vicryl® from Ethicon, are chemically different from PGA homopolymer and are not interchangeable 1:1 without validation by the technical department. The cited brands belong to their respective manufacturers and are mentioned only as a reference for equivalence.

5. Selection tips and variants of interest

The USP 3/0 gauge (metric 2) offers an ideal balance between initial strength and handling for tissues with moderate mechanical demand: approximation of soft tissues, skin closures, subcutaneous planes and ligatures. The DS19 needle of 19 mm with a reverse cutting triangular point is indicated when it is necessary to penetrate firm tissues without tearing (skin, fascia, aponeurosis) in surgical fields of medium or reduced size. The violet colour favours the visibility of the thread during the intervention; if maximum aesthetic discretion is preferred, there is a colourless version of the same configuration.

Reference Variant
AM112DS1930 (112DS1930) PGA USP 3/0, ⅜ triangular needle DS19 mm, violet, 75 cm (current product)
AM122DS1930 PGA USP 3/0, same needle DS19 mm, colourless, 75 cm (colourless variant)
AMP112DS1930 PGA Prime quality USP 3/0, DS19 mm needle, violet, 75 cm (superior quality)
AM112DS1940 PGA USP 4/0, DS19 mm needle, violet, 75 cm (finer gauge)
AM112DS1950 PGA USP 5/0, DS19 mm needle, violet, 75 cm (finer gauge)
AM112DS1630 PGA USP 3/0, DS16 mm needle, violet, 75 cm (shorter needle)
1L12DS1930 PGLA (polyglactin 910) USP 3/0, DS19 mm needle, violet, 75 cm (absorption 56-72 days)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer reference

112DS1930

Material

100% Polyglycolic Acid (PGA) absorbable by hydrolysis

Coating

Polycaprolactone and calcium stearate

Gauge

USP 3/0 (metric 2)

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Presentation

Box of 12 units

Minimum order

30 boxes

Intended use

Tissue approximation, ligatures and general surgery

Thread structure

Braided multifilament with grooved finish

USP size

USP 3/0 (metric 2)

Thread diameter

0.20 – 0.249 mm (indicative according to USP/EP)

Needle shape

3/8 circle (approx. 135°)

Tip type

Reverse cutting triangular (inverted triangular / reverse cutting), body and point

Needle size

DS19 (19 mm), 1 needle per thread

Regulatory standard

USP / European Pharmacopoeia (EP)

Quality

Standard (range Premisut)

Use

Single-use, not re-sterilisable

Medida de aguja

DS 19

Usp

3/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture (Polyglycolic Acid) | 3/8 Circle Needle Reverse Cutting Triangular Point DS19 (19 mm) | USP 3/0 (Metric 2) | Violet Fluted Thread 75 cm | Ref. 112DS1930 | Box of 12 units”

Your email address will not be published. Required fields are marked *