Description
1. Commercial Introduction
The PGA Prime Absorbable Multifilament Suture is the reference solution for approximation and ligation of soft tissues in general surgery and surgical specialties. Made from 100% braided and coated polyglycolic acid (PGA), it offers predictable absorption by hydrolysis between 60 and 90 days, excellent knot security and minimal tissue reaction. This presentation in USP 6/0 gauge mounts a ⅜ circle needle with cylindrical body and taperpoint conical point of 9.3 mm (DR 9.3 Prime profile) and a violet thread of 45 cm, configured for precision work on lax, vascular and well-irrigated tissues. It is supplied sterile, ready for single use, in a box of 12 units with batch traceability, in a B2B format aimed at hospital replenishment and public tenders. Article reference P111DR9,360 (SKU Cahnos AMP111DR9,360).
2. Technical Explanation
The polyglycolic acid (PGA) thread is a synthetic absorbable homopolymer presented as a braided multifilament, coated with polycaprolactone and calcium stearate to improve glide and knot security. Its absorption occurs by hydrolysis, ensuring predictable mass loss without depending on tissue enzymes. The tensile strength retention curve is as follows: 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, with complete reabsorption between days 60 and 90. The DR 9.3 Prime needle (⅜ circle, cylindrical body and taperpoint conical point) penetrates tissues by separating fibres without cutting them, reducing trauma and bleeding at the passage point; the USP 6/0 gauge (metric EP 0.7) is a fine thread with adequate strength for delicate soft tissue sutures, vascular ligations and mucosa. The product is sterile by ethylene oxide (EO) and single-use: do not re-sterilize.
3. Technical Specifications
| Parameter | Specification |
| Thread material | 100% polyglycolic acid (PGA) multifilament braided, coated with polycaprolactone and calcium stearate |
| Structure | Braided multifilament, non-ribbed |
| Suture type | Synthetic absorbable (medium duration) |
| USP gauge / size | USP 6/0 (metric EP 0.7) |
| Thread length | 45 cm (1 strand per unit) |
| Thread colour | Violet (also available colourless in the range) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Cylindrical body, conical tip (taperpoint) |
| Needle size | 9.3 mm (DR 9.3 Prime profile) |
| Absorption | By hydrolysis in 60–90 days |
| Tensile strength retention | 75% at 2 weeks; 50% at 3 weeks; 40% at 4 weeks |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, general surgery, gynaecology, urology and paediatric surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Article reference | P111DR9,360 |
| SKU Cahnos | AMP111DR9,360 |
4. Equivalences and Cross-References
The reference P111DR9,360 corresponds to the official nomenclature of the PGA Prime suture range (DR 9.3 Prime profile, single needle with taperpoint conical point of 9.3 mm, USP 6/0 gauge, violet thread of 45 cm). Cahnos markets the product keeping the article reference unchanged. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands: the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | SAFIL® – braided coated PGA, violet, USP 6/0 (0.7) gauge, DR12 needle with round body and conical point, 70 cm thread | C1048434 (verified in GUDID/FDA and official catalogue B. Braun) | Comparable by category (not interchangeable 1:1) | They match in material (100% braided coated PGA), 6/0 gauge, violet colour and DR conical needle geometry; needle of 12 mm and thread of 70 cm versus 9.3 mm and 45 cm |
| B. Braun (Aesculap) | SAFIL® – braided coated PGA, violet, USP 7/0 (0.5) gauge, DR10 needle with round body and conical point, 45 cm thread | C1048101 (verified in GUDID/FDA and official catalogue B. Braun) | Comparable by category (not interchangeable 1:1) | Same material, same conical geometry and same length of 45 cm; 7/0 gauge finer and needle of 10 mm versus 9.3 mm; not interchangeable in gauge |
| B. Braun (Aesculap) | SAFIL® – braided coated PGA, violet, USP 5/0 gauge (1), DR10 needle with round body conical point, 45 cm thread | C1048103 (verified in GUDID/FDA and official catalogue B. Braun) | Comparable by category (not interchangeable 1:1) | Same material, same conical geometry and same length of 45 cm; 5/0 gauge thicker and needle of 10 mm versus 9.3 mm; not interchangeable in gauge |
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands. As homologous market families with the same usage profile (medium-duration braided absorbable suture for soft tissue) can be cited, without verified code in active public sources: the DEXON® II range (Medtronic/Covidien, braided PGA, discontinued in most markets) and the VICRYL® range (Ethicon, polyglactin 910/PGLA 90:10, a copolymer different from PGA homopolymer and with its own absorption profile). This needle geometry (DR 9.3 taperpoint, USP 6/0, 45 cm) is only fully safely interchangeable within the Prime range system itself. Consult the technical department of Cahnos to validate any equivalence before use in tenders.
5. Selection tips and variants of interest
Tissue to suture: the USP 6/0 gauge (metric EP 0.7) is a fine thread with good handling, indicated for approximation of soft tissues, ligations, mucosa, subcutaneous planes and paediatric surgery. The DR needle with conical point (taperpoint) separates fibres without cutting them: it is the natural choice for lax, well-irrigated tissues and vascular structures; for planes requiring greater penetration (skin, fascia), consider the triangular point profiles of the same PGA Prime range.
Needle size: the DR 9.3 mm profile offers an intermediate-high length within the conical family, ideal for medium working surgical fields. If you need a shorter needle while maintaining the same material, the PGA Prime range offers the DR 6.5 mm profile with USP 8/0 gauge and 30 cm thread (SKU AMP114DR6,580); for techniques requiring a trocar point with the same polymer, it offers the DRT 13 mm profile in USP 6/0 with 70 cm thread (AMP118DRT1360).
Material alternatives: if the protocol requires longer wound support (180–210 days), the range offers monofilament polydioxanone (PDO) suture with the same DR 9.3 needle in 6/0 gauge and double armed (AMP418DR9,360-2). Unifying supplier across the entire absorbable suture portfolio allows B2B volume conditions.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P111DR9,360 and the batch number for traceability in the operating theatre and in case of complaint. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews